• 제목/요약/키워드: Electrocardiography (ECG)

검색결과 80건 처리시간 0.028초

Study on Reusable Electrodes for Personal Electrocardiography

  • Kim, Jonghoon;Yoon, Gilwon
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.340-344
    • /
    • 2018
  • Electrodes are an important part of electrocardiography (ECG); disposable electrodes have been extensively used. However, personal ECG monitoring devices for Internet of Things applications require reusable electrodes. As there have been no systematic studies on the characteristics of reusable electrodes to date, we conducted this study to assess the performance and feasibility of electrodes with different materials. We built reusable electrodes using twelve different metallic materials, including commonly used copper, silver, zinc, plating materials, chemically inert titanium, stainless steel, and aluminum. Each electrode was fabricated to a size of $5{\times}10mm$. Their characteristics such as offset, baseline drift, stabilization time, and chemical inertness were compared. A personal ECG monitoring system was used to test the manufactured electrodes. The performances of the Ag, Cu, and Zn electrodes were better than the performances of other electrodes. However, these materials may not be used owing to the chemical changes that occur when the electrodes are in contact with the skin, such as discoloration and corrosion, which deteriorate their electrical characteristics. Titanium, stainless steel, and aluminum are chemically stable. The titanium electrode showed the best performance among the three, and it is our recommendation as a material for manufacturing reusable electrodes.

Detection of Arrhythmias by Holter Monitoring and Use of Wearable Electrocardiography Devices Holter and wearable devices for arrhythmia detection

  • Ji Yeon Chang;Jae Kyung Kim
    • International Journal of Advanced Culture Technology
    • /
    • 제11권2호
    • /
    • pp.310-314
    • /
    • 2023
  • In this paper, we show that the limitations of Holter monitoring and Wearable Electrocardiogarphy Devices and their arrhythmia detection. Sudden death caused by cardiovascular disease, often referred to as the "silent killer" due to its unpredictable nature, is a major health concern. Electrocardiography (ECG) is a basic diagnostic tool for detecting heart disease, but its limitations make it difficult to detect arrhythmia, a significant indicator of an irregular heart state. To address this limitation, a long-term continuous ECG recording device has been developed, Holter ECG device and wearable device. A significant number of studies have focused on the differences between Holter monitoring and wearable devices. The Holter tests were useful for detecting regularly occurring arrhythmias, whereas wearable patches were better at detecting random and infrequent arrhythmias. Wearable patches were effective in detecting episodes of arrhythmia and myocardial ischemia. Despite the concern, wearable devices had less signal loss than Holter monitoring and patients also preferred wearable devices over Holter monitoring due to convenience. These results could mean that the wearable devices can perfectly replace the Holter test.

심전도(LF/HF)를 활용한 졸음운전 예방 연구 (Study on Prevention of Drowsiness Driving using Electrocardiography(LF/HF) Index)

  • 문광수;황경인;최은주;오세진
    • 한국안전학회지
    • /
    • 제30권2호
    • /
    • pp.56-62
    • /
    • 2015
  • The purpose of this study was to identify the relationship between the index of Electrocardiography(LF/HF) and the occurrence of drowsiness driving while driving in a simulated situation. Participants were 31 undergraduate students with an experience in driving and they participated 30 minutes driving under enough sleep condition and 1 hour under the sleep deprivation condition. The Euro Truck Simulator II was used for driving simulation task and ECG and perceived drowsiness of each participants were measured during two driving conditions. Perceived sleepiness recorded by the checklist every 10 minutes and ECG data extracted before and after 15 seconds of every 10 minutes to verify the relationship between two variables. The results showed that the level of perceived sleepiness under sleep deprivation condition was higher than that under the enough sleep condition, and the level of LF/HF under sleep deprivation condition was lower than that under the enough sleep condition. In addition, the result of analysis of repeated measure ANOVA for ECG indicated that authentic sleepiness revealed in 20 minutes after the start of driving under the sleep deprivation condition. However, the result of perceived drowsiness indicated that authentic sleepiness revealed in 30 minutes after the start of driving. These result suggest that the time difference between biological and perceived response on drowsiness may be exist. Finally, the significant negative correlation between the LF/HF level and perceived drowsiness was observed. These findings suggest that ECG(LF/HF) can be an possible index to measure drowsiness driving.

PPG 및 ECG 센서를 이용한 혈압추정 기법 개발 (Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors)

  • 박현문;이정철;황태호
    • 한국전자통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1257-1264
    • /
    • 2019
  • 기존의 Cuff 기반의 혈압(Blood Pressure)측정 방법은 연속적인 실시간 혈압측정에는 한계를 갖는다. 이러한 이유로 ECG와 PPG 센서 신호를 상호융합한 다양한 혈압추정이 이루어졌다. 그러나 PPG 중심에 측정기법은 AC 노이즈, 작은 맥동, 비박동 등의 많은 문제를 지니고 있다. 본 논문은 ECG와 PPG 관계에 발생하는 맥파전달시간(PTT)과 맥파속도(PWV)를 이용하여 혈압을 추론기법이다. 신호 피크를 이용하는 HRF(Height Ratio Features)에 비해, 본 제안방식은 ECG, PPG의 최고점 혹은 최저점을 사용한 시차를 이용해 추정하기 때문에 PPG 센싱 시그널의 오류에도 안정적인 추출이 가능한 장점이 있다. 본 논문에서 제안 방법을 이용하여 25만 회의 혈압측정의 결과 ±28.5%의 정확도를 갖는 혈압 추정기법을 제시할 수 있었다.

Hypokalemia as a risk factor for prolonged QT interval and arrhythmia in inherited salt-losing tubulopathy

  • Seong Ryeong Kang;Yo Han Ahn;Hee Gyung Kang;Naye Choi
    • Childhood Kidney Diseases
    • /
    • 제27권2호
    • /
    • pp.105-110
    • /
    • 2023
  • Purpose: To analyze electrocardiograms (ECGs) of patients with a salt-losing tubulopathy (SLT) and to determine the frequency and risk factors for long QT and arrhythmia. Methods: A total of 203 patients aged <19 years with SLT, specifically Bartter syndrome and Gitelman syndrome, who had a 12-lead ECG were included in this retrospective study. We analyzed the presence of an arrhythmia or prolonged corrected QT (QTc) on ECGs obtained for these patients. Demographic and laboratory data were compared between patients with abnormal and normal ECG findings. Results: Out of the 203 SLT patients, 38 (18.7%) underwent electrocardiography and 10 (40.0%) of 25 patients with inherited SLT had abnormal ECG findings, including prolonged QTc and arrhythmias. The abnormal ECG group had significantly lower serum potassium levels than the normal group (median [interquartile range]: 2.50 mmol/L [2.20-2.83] vs. 2.90 mmol/L [2.70-3.30], P=0.036), whereas other serum chemistry values did not show significant differences. The cutoff level for a significant difference in QTc interval was serum potassium level <2.50 mmol/L. One cardiac event occurred in a 13-year-old boy, who developed paroxysmal supraventricular tachycardia and underwent cardiac ablation. No sudden cardiac deaths occurred in this cohort. Conclusions: The incidence of ECG abnormalities in patients with inherited SLT was 40.0%, whereas the ECG screening rate was relatively low (18.7%). Therefore, we recommend ECG screening in patients with inherited SLT, especially in those with serum potassium level <2.50 mmol/L.

Evaluation of the Diagnostic Performance and Efficacy of Wearable Electrocardiogram Monitoring for Arrhythmia Detection after Cardiac Surgery

  • Seungji Hyun;Seungwook Lee;Yu Sun Hong;Sang-hyun Lim;Do Jung Kim
    • Journal of Chest Surgery
    • /
    • 제57권2호
    • /
    • pp.205-212
    • /
    • 2024
  • Background: Postoperative atrial fibrillation (A-fib) is a serious complication of cardiac surgery that is associated with increased mortality and morbidity. Traditional 24-hour Holter monitors have limitations, which have prompted the development of innovative wearable electrocardiogram (ECG) monitoring devices. This study assessed a patch-type wearable ECG device (MobiCARE-MC100) for monitoring A-fib in patients undergoing cardiac surgery and compared it with 24-hour Holter ECG monitoring. Methods: This was a single-center, prospective, investigator-initiated cohort study that included 39 patients who underwent cardiac surgery between July 2021 and June 2022. Patients underwent simultaneous monitoring with both conventional Holter and patchtype ECG devices for 24 hours. The Holter device was then removed, and patch-type monitoring continued for an additional 48 hours, to determine whether extended monitoring provided benefits in the detection of A-fib. Results: This 72-hour ECG monitoring study included 39 patients, with an average age of 62.2 years, comprising 29 men (74.4%) and 10 women (25.6%). In the initial 24 hours, both monitoring techniques identified the same number of paroxysmal A-fib in 7 out of 39 patients. After 24 hours of monitoring, during the additional 48-hour assessment using the patch-type ECG device, an increase in A-fib burden (9%→38%) was observed in 1 patient. Most patients reported no significant discomfort while using the MobiCARE device. Conclusion: In patients who underwent cardiac surgery, the mobiCARE device demonstrated diagnostic accuracy comparable to that of the conventional Holter monitoring system.

국산 심전계 개발에 관한 연구 (A Study on the Development of Electrocardiography GSM 110A)

  • 이흥규;함영욱;김용만
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권2호
    • /
    • pp.123-130
    • /
    • 1982
  • In this paper, Electrocardiography principles and design philosophy are discussed. 1-channel portable automatic ECG amplifier, GSM 110A has high reliability, performance and safety. It reveals that GSM 110A satisfies the IEC, VDE standards. Clinical tests are performed and proved its performance and ease of use.

  • PDF

활로씨 4징의 교정 수술 후 심전도와 신호 평준화 심전도의 변화 (The changes of electrocardiography and signal-averaged electrocardiography after surgical repair of Tetralogy of Fallot)

  • 서혜은;임해리;김여향;현명철;이상범
    • Clinical and Experimental Pediatrics
    • /
    • 제50권5호
    • /
    • pp.462-468
    • /
    • 2007
  • 목 적 : 활로씨 4징 교정 수술을 받은 환자들에서 추적관찰 기간 동안 신호 평준화 심전도, 표준 12 유도 심전도 검사를 반복적으로 시행하고, 신호 평준화 심전도 상의 후전위, 심전도상의 QRS 기간, QT 간격 및 JT 간격, QRS 기간 분산, QT 간격 분산 및 JT 간격 분산을 측정하여 우심실 용적 부하 기간에 따른 변화를 알아보고자 하였다. 방 법 : 1985년 이후 경북대학교병원에서 활로씨 4징 교정 수술을 받고 1999년과 2005년에 표준 12 유도 심전도와 신호 평준화 심전도를 추적 관찰할 수 있었던 환자 9명을 대상으로 하였다. 대상 환자에서 1999년을 시점 1로, 2005년을 시점 2로 하여 각 시점별로 시행된 12 유도 심전도와 신호 평준화 심전도를 검토하여 표준 12 유도 심전도에서는 QRS 기간, QT 간격 및 JT 간격, QRS 기간 분산, QT 간격 분산 및 JT 간격 분산, SAECG에서는 f-QRS, HFLA, RMS, MV를 측정하였다. 결 과 : 시점 1과 시점 2 사이에서 JT 간격 분산은 통계학적으로 의미 있는 감소가 있었고($101.11{\pm}50.11$ vs $71.11{\pm}22.61ms$, P<0.05), HFLA는 통계학적으로 의미 있는 증가가 있었다($24.67{\pm}13.19$ vs $32.89{\pm}14.21ms$, P<0.05). 그러나 다른 계측치들은 유의한 차이가 없었다. 결 론 : 활로씨 4징 환자의 교정 수술 후 발생할 수 있는 폐동맥 역류증, 우심실 확장, 심실성 부정맥, 급사 등의 후기 부작용을 발견하기 위해 추적 관찰 기간 동안 심전도 및 신호 평준화 심전도를 시행 하였고,일부 계측치에서 유의한 변화를 발견할 수 있었다(JT dispersion, HFLA). 그러나 이러한 계측치의 유의한 변화와 활로씨 4징 환자의 수술 후 예후간의 관계를 규명하기 위해 더 많은 환자에서 더욱 장기적인 추적 관찰이 필요하다.

ECG 기반의 운전자별 인지 부하 평가 방법 개발 (Development of an Evaluation Method for a Driver's Cognitive Workload Using ECG Signal)

  • 홍원기;이원섭;정기효;이백희;박장운;박수완;박윤숙;손준우;박세권;유희천
    • 대한산업공학회지
    • /
    • 제40권3호
    • /
    • pp.325-332
    • /
    • 2014
  • High cognitive workload decreases a driver's ability of judgement and response in traffic situation and could result in a traffic accident. Electrocardiography (ECG) has been used for evaluation of drivers' cognitive workload; however, individual differences in ECG response corresponding to cognitive workload have not been fully considered. The present study developed an evaluation method of individual driver's cognitive workload based on ECG data, and evaluated its usefulness through an experiment in a driving simulator. The evaluation method developed by the present study determined the optimal ECG evaluation condition for individual participant by analysis of area under the receiver operating characteristic curve (AUC) for various conditions (total number of conditions = 144) in terms of four aspects (ECG measure, window span, update rate, and workload level). AUC analysis on the various conditions showed that the optimal ECG evaluation condition for each participant was significantly different. In addition, the optimal ECG evaluation condition could accurately detect changes in cognitive workload for 47% of the total participants (n = 15). The evaluation method proposed in the present study can be utilized in the evaluation of individual driver's cognitive workload for an intelligent vehicle.

심음, 심전 신호처리 및 해석에 관한 연구 (A Study on PCG-ECG Signal Processing and Analysis)

  • 이대희;양원영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.905-907
    • /
    • 1991
  • One of the general methods to diagnose abnormalities of heart is stethoscopy. This method needs special skill and experiment of doctors and it lacks for objectivity. Electrocardiography(ECG) is another biomedical method which is commonly used to diagnoss abnormalities of heart. The development of PCG is required in recent years to improve objectivity of stethoscopy method. In this paper, PCG is implemented on personal computer and ECG is also included to help the analysis of PCG waveform. Time analysis is used so far, but in this paper the frequency analysis is also considered to improve the accuracy of disgonosis. As future research, recognition of PCG and ECG signal and the Expert System is required to improve the accuracy of diagnosis.

  • PDF