• 제목/요약/키워드: Electro-hyperthermia

검색결과 5건 처리시간 0.019초

Synthesis of Gold Nanoparticles by Electro-reduction Method and Their Application as an Electro-hyperthermia System

  • Yoon, Young Il;Kim, Kwang-Soo;Kwon, Yong-Soo;Cho, Hee-Sang;Lee, Hak Jong;Yoon, Chang-Jin;Yoon, Tae-Jong
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권6호
    • /
    • pp.1806-1808
    • /
    • 2014
  • We report the successful preparation of gold nanoparticles (Au NPs) using a novel electroreduction process, which is simple, fast, and environmentally friendly (toxic chemicals such as strong reducing agents are not required). Our process allows for the mass production of Au NPs and adequate particle size control. The Au NPs prepared show high biocompatibility and are non-toxic to healthy human cells. By applying radio-frequency (RF) ablation, we monitored the electro-hyperthermia effect of the Au NPs at different RFs. The Au NPs exhibit a fast increase in temperature to $55^{\circ}C$ within 5 min during the application of an RF of 13 MHz. This temperature rise is sufficient to promote apoptosis through thermal stress. Our work suggests that the selective Au NP-mediated electro-hyperthermia therapy for tumor cells under an RF of 13 MHz has great potential as a clinical treatment for specific tumor ablation.

Microwave Cavity with Controllable Temperature for In Vitro Hyperthermia Investigations

  • Kiourti, Asimina;Sun, Mingrui;He, Xiaoming;Volakis, John L.
    • Journal of electromagnetic engineering and science
    • /
    • 제14권3호
    • /
    • pp.267-272
    • /
    • 2014
  • Hyperthermia is a form of cancer treatment in which affected human tissue is exposed to $>40^{\circ}C$ temperature. In this paper, our goal is to assess the efficacy of fullerene agents to reduce heating time for cancer treatment. Such agents can accelerate heating of cancer cells and improve hyperthermia treatment efficacy. Typically, in vitro testing involves cancer cell culturing, heating cell cultures in accordance to specifications, and recording cancer cell viability after hyperthermia. To heat cell cultures, we design and evaluate a 2.4-GHz microwave cavity with controllable temperature. The cavity is comprised of a polystyrene cell culture dish (diameter = 54 mm, height = 13.5 mm) and a printed monopole antenna placed within the cavity for microwave heating. The culture temperature can be controlled through the intensity and duration of the antenna's microwave radiation. Heating experiments were carried out to validate the cavity's performance for F-12K culture medium (Kaighn's F-12K medium, ATCC). Importantly, fullerene agents were shown to reduce heating time and improve hyperthermia treatment efficacy. The culture medium temperature increased, on average, from $24.0^{\circ}C$ to $50.9^{\circ}C$ (without fullerene) and from $24.0^{\circ}C$ to $56.8^{\circ}C$ (with 3 mg/mL fullerene) within 15 minutes.

A Proposal of Both Use of Direct Moxibustion and Electro-Moxibustion for Cancer Treatment Moxibustion

  • Jo, Bong Kwan;Jeon, Soo Hyung;Kim, Jong Won
    • 대한한의학회지
    • /
    • 제38권4호
    • /
    • pp.82-89
    • /
    • 2017
  • Objectives: We here do propose that cancer treatment moxibustion should be used both direct moxibustion and electro-moxibustion simultaneously. Methods: Electro-moxibustion is used in $38^{\circ}C$ low-heat level and it will help to raise parasympathetic and to bring stability of mentality. Direct moxibustion is used in rice size and will help to raise sympathetic and to induce visceral reflection and visceral motion. Results: Electro-moxibustion increased average body heat by $+2.51^{\circ}C$ and kept patients from suffering pains. Direct moxibustion increased average body heat by $+1.2^{\circ}C$ by meridian point-internal organs reflection. Conclusions: Both use of direct moxibustion and electro-moxibustion simultaneously will be superior to the only either direct moxibustion or electro-moxibustion for cancer treatment moxibustion.

In vivo verification of regional hyperthermia in the liver

  • Noh, Jae Myoung;Kim, Hye Young;Park, Hee Chul;Lee, So Hyang;Kim, Young-Sun;Hong, Saet-Byul;Park, Ji Hyun;Jung, Sang Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • 제32권4호
    • /
    • pp.256-261
    • /
    • 2014
  • Purpose: We performed invasive thermometry to verify the elevation of local temperature in the liver during hyperthermia. Materials and Methods: Three 40-kg pigs were used for the experiments. Under general anesthesia with ultrasonography guidance, two glass fiber-optic sensors were placed in the liver, and one was placed in the peritoneal cavity in front of the liver. Another sensor was placed on the skin surface to assess superficial cooling. Six sessions of hyperthermia were delivered using the Celsius TCS electro-hyperthermia system. The energy delivered was increased from 240 kJ to 507 kJ during the 60-minute sessions. The inter-session cooling periods were at least 30 minutes. The temperature was recorded every 5 minutes by the four sensors during hyperthermia, and the increased temperatures recorded during the consecutive sessions were analyzed. Results: As the animals were anesthetized, the baseline temperature at the start of each session decreased by $1.3^{\circ}C$ to $2.8^{\circ}C$ (median, $2.1^{\circ}C$). The mean increases in temperature measured by the intrahepatic sensors were $2.42^{\circ}C$ (95% confidence interval [CI], 1.70-3.13) and $2.67^{\circ}C$ (95% CI, 2.05-3.28) during the fifth and sixth sessions, respectively. The corresponding values for the intraperitoneal sensor were $2.10^{\circ}C$ (95% CI, 0.71-3.49) and $2.87^{\circ}C$ (1.13-4.43), respectively. Conversely, the skin temperature was not increased but rather decreased according to application of the cooling system. Conclusion: We observed mean $2.67^{\circ}C$ and $2.87^{\circ}C$ increases in temperature at the liver and peritoneal cavity, respectively, during hyperthermia. In vivo real-time thermometry is useful for directly measuring internal temperature during hyperthermia.

출산 후 요통에 대한 추나요법의 효과: 체계적 문헌고찰 (Chuna Manual Therapy for Postpartum Low Back Pain: Systematic Review)

  • 조주찬;박인화;황만석;허인
    • 척추신경추나의학회지
    • /
    • 제16권2호
    • /
    • pp.1-8
    • /
    • 2021
  • Objectives This study aimed to evaluate the effect of chuna manual therapy (CMT) for postpartum low back pain using a systematic review. Methods We performed a literature search using 12 electronic databases up to the end of September 2021. We included randomized controlled trials (RCTs) that evaluated the effect of CMT in the treatment of postpartum low back pain. The risk of bias was evaluated using the Cochrane risk-of-bias tool. Results Four randomized controlled trials were reported statistically significant effect in pain VAS, ODI and JOA of chuna manual therapy compared with moxibution, electro acupuncture, hyperthermia or usual care. As a result of assessing the risk of bias tool, most of the contents of the evaluation items were not identified, so it was evaluated as an uncertain risk. Conclusions CMT may be effective in treating postpartum low back pain. However, evidence was limited due to the small sample size, lack of well-designed RCTs and regional bias. Further well-designed studies are required to obtain stronger evidence.