• Title/Summary/Keyword: Electro-Magnetic Wave Environment

Search Result 17, Processing Time 0.028 seconds

Algorithm Study for Diagnosis the Breast Cancer Using LMA and FDTD (LMA와 FDTD를 이용한 유방암 진단용 알고리즘 연구)

  • Seo, Min-Gyeong;Kim, Tae-Hong;Mun, Ji-Yeon;Jeon, Soon-Ik;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1124-1131
    • /
    • 2011
  • In this paper, image reconstruction algorithm for breast cancer detection using MT(Microwave Tomography) was investigated. The breast cancer detection system under development uses 16 transmit/receive antennas. The signal waveform was a sinusoidal wave at 900 MHz. To solve the 2D inverse scattering problem, we used the 2D FDTD (Finite Difference Time Domain) method for forward calculation and LMA(Levenberg-Marquardt Algorithm) for optimization. The result of the image reconstruction using the numerical phantom by MRI(Magnetic Resonance Imaging) obtained from real patient of breast cancer showed that we can detect the position of the tumor accurately.

Underwater Acoustic Communication Link Analysis (수중음향통신 링크 해석)

  • Choi, Young-Chol;Byun, Sung-Hoon;Lim, Yong-Kon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1465-1471
    • /
    • 2007
  • The electro-magnetic wave propagates through the air in the terrestrial communications, but the acoustic wave propagates through the seawater in the underwater acoustic communication(UAC). It makes the differences between the UAC link and the well hon air communication links. In this paper, we have studied path loss, absorption and ambient noise of the ocean as a medium for UAC. We have analyzed the absorption coefficient and ambient noise level of the coastal area of South Korea and suggested a strategy for the selection of the frequency band by considering the absorption coefficient and ambient noise level. Also, we present an illustrative example of a link budget for the QPSK UAC system which has carrier frequency 25kHz, bit rate 10kbps, range 1km and BER $10^{-3}$ in the shallow water environment with an ideal AWGN assumption.

A Development of Dielectric Measurement System for Detecting Physical Parameters of Ground in Subsurface Dam (지하댐 지반 물성치 측정을 위한 유전율 측정 시스템 개발)

  • Kim Man-il;Jeong Gyo-Cheol;Park Chang-Kun
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.361-369
    • /
    • 2004
  • The authors designed a new technique to measure dielectric constant of a soil media by Frequency Domain Reflectometry (FDR) system and its measurement sensor probe with different length such as 7m, 10cm and 15cm for estimating the variations of dielectric constant. Measurement of dielectric constant of soil material is possible to measure an interference wave generated by between incidence wave and reflection wave which are detected to electro-magnetic wave through the directional coupler at the high frequency range,0.1 to 1.7GHz, by FDR system. The obtained experimental results verified that the technique is very promising for non-destructive and continuous soil volumetric water content measurement monitoring in a laboratory. The relationship between the soil volumetric water content and the dielectric constant of soil media (standard sand) was expressed by a single regression ewe independent of soil texture at a small experimental error. Also the derived regression curve coincided well with that obtained by Topp curve.

Path-Loss Modeling for Human Channel of WBAN System (WBAN 시스템용 인체 채널에 대한 경로 손실 모델링)

  • Mun, Ji-Yeon;Kim, Tae-Hong;Seo, Min-Gyeong;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1116-1123
    • /
    • 2011
  • In this paper, we studied the propagation of the radio wave in the human body for WBAN system and proposed the path-loss models applicable in the MICS and ISM frequency band. Human Tissues are composed of complicate organ. So it is difficult to measure to insert the probe in human body. Accordingly, the equations were modelled by electromagnetic analysis using the numerical phantom based on the real human. The numerical analysis used XFDTD 6.5 of Remcom co. in commercial software based on the Finite-Difference Time-Domain method. Human body model used a standard adult Korean model developed by ETRI. The proposed channel models will be very helpful to design the WBAN system.

Development of a Physical Training Management Module Using Smart Devices (스마트기기를 이용한 운동량 관리모듈 개발)

  • Shin, Ki-Su;Jung, Hahmin;Kwon, Soon-Jae;Lee, Se-Han;Kim, Dong Hun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.6
    • /
    • pp.571-577
    • /
    • 2015
  • In the paper, we propose a method for developing a physical training management module which sends physical data to smart devices using an wireless module attached to physical appliances. In the proposed stick-type physical appliance, the physical amount of data measured from sensors inside the appliance is sent to a smart device via wireless communication. And then the smart device records the physical amount of data categorized in person-based data and shows useful information about the user's physical training on the dedicated display. For the performance evaluation, indoor environment and electro magnetic wave tests are taken from national specialized organizations, and their results was very efficient. The proposed physical training management module is highly extensible since it is easily applicable to other physical appliances and useful to both Android and iOS platforms.

Performance analysis of CSMA based MAC protocols for underwater communications (수중 통신에 적합한 CSMA기반 매체접근제어 프로토콜 연구)

  • Song, Min-Je;Jang, Youn-Seon
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1068-1072
    • /
    • 2018
  • In underwater communications, there are many challenges due to energy limitations, long propagation delay, low data rate, and high power loss, unlike terrestrial RF communications. Especially, the propagation delay of underwater acoustic channel is five orders of magnitude higher than in electro-magnetic terrestrial channels due to the low speed of sound(1,500m/s). Thus, the MAC protocols for terrestrial communications are not suitable for underwater network. In this paper, we studied the considerations for MAC protocol in underwater acoustic channel. Here, we concentrated on CSMA based MAC protocols. From the results, we confirmed that the number of control packets has an important effect on the performance in underwater environment. These results would be useful in designing MAC protocols for underwater acoustic communications.

Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply (레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석)

  • Ryu, Ji-Ho;Cho, Chong-Hyeon;Chong, Min-Kil;Park, Sung-Jin;Kang, Kwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.