• Title/Summary/Keyword: Electro-Acupuncture According to Voll(EAV)

Search Result 5, Processing Time 0.02 seconds

Reliability of Two Electrodermal Meridian Measurement Systems: EAV and Newly Developed MIR-1 (경락노선상 피부전기 측정기 (EAV, MIR-1) 의 신뢰도 연구)

  • Yin, Chang-Shik;Hoe, Ik-Beom;Lee, Yoo-Jeong;Sakong, Sug-Chin;Koh, Hyeong-Gyun;Park, Young-Bae;Lee, Woo-Cheol
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.125-130
    • /
    • 2005
  • Background and purpose: We evaluated the reliability of two electrodermal measurement devices on meridian skin areas; Electro Acupuncture according to Dr. Voll (EAV) method and newly developed MIR-1. Methods: Eighteen volunteers were tested repeatedly on the same condition with each device. To explore the intra-rater, inter-rater, and test-retest reliabilities, one rater tested each subject twice in succession, then the other rater tested the subject in a row. Finally, retests on the subjects with each device were performed 1 week later. The reliability was determined by Pearson correlation and intraclass correlation statistics. Results: EAV method showed poor reliability, while MIR-1 showed good reliability. Conclusion: It is suggested that further research on the reliability and useful device in both fields of clinical practice and biomedical research.

  • PDF

Clinical diagnostic study of Physiological Signal data measured on 58 cases of numbness with EAV(Electro-puncture According to Voll) (비증환자(痺證患者) 58례(例)에 대(對)한 EAV측정치(測定値)의 진단적(診斷的) 고찰(考察))

  • Han, Sang-Gyun;Ha, Chi-Hong;Cho, Myung-Rae;Ryu, Chung-Ryul;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.91-100
    • /
    • 2001
  • Background and Objective : Most diagnostic method for numbness were invasive and complex. So we need to simplify and objectify diagnostic method for numbness. Some study with EAV which is one of Physiological Signal Measuring Instruments, report significantly result as objective diagnostic method for other clinical symptom. By using EAV, we have obtained some physiological signal data from meridian-acupoints of 58 numbness cases. Objective and Methods : This study researched into the clinical statistics for 58 case who ware in numbness, and they ware treated with oriental medical care at the Dong-shin university oriental hospital during 1 year from April 3 2000 to March 30 2001. The data were analyzed and interpreted to compare with traditional differentiation of symptom-complexes, then further evaluated as the Five Evolutive Phases to make them differentiated. The EAV valus of Five Evolutive Phases were identified with the sequence of wood(木), fire(火), earth(土), steel(金), water(水). Results and Conclusion : These values of physiological signal were identical with standard differentiation of symptom-complexes of numbness which is the main cause of dishannonious flow of Qi and blood of the in the liver and deficiency of Qi and blood of the bladder with stagnancy of dampness. Among Five Evolutive Phases, Earth and wood values were increased, steel, fire and water were decreased significantly. This data imply the possibility of somewhat generalization from measuring instruments.

  • PDF

The Studies on Qigong state Using EEG, fMRI, EAV and SQUID Measurments (EEG, fMRI, EAV 및 SQUID장치(裝置)를 이용(利用)한 기공현상(氣功現狀) 측정(測定))

  • Jeong, Chan-Won;Choi, Chan-Hun;Yoon, Wu-Sik;So, Cheal-Ho;Na, Chang-Su;Jang, Kyeong-Seon
    • Korean Journal of Acupuncture
    • /
    • v.21 no.2
    • /
    • pp.1-28
    • /
    • 2004
  • Objectives : Human physiological changes in the state of qigong has been measured using EEG(Electroencephalography), functional MRI(functional Magnetic Resonance Image), EAV(Electro-Acupuncture according to Voll) and SQUID(Superconducting Quantum Interference Device) measurements. Methods & Results : EEGs were measured to study the differences between Qigong masters and Qi receiver on the changes of EEG. During Qigong, an alpha waves were increased. The power spectra indicate that the peak frequency of alpha waves increased during Qigong. Qi receiver's EEG signals seemed to affected by the state of himself. Brain activation did not observed when qigong master concentrates the Qi at Laogong(P8). But a localization of fMRI signal in the sensory cortex was observed by electric acupuncture stimulation at Laogong(P8). Five phase deviation of EAV were clearly changed in the both cases of Qigong master and Qi receiver. When a Qigong master concentrates the Qi at Yintang, Laogong(P8), Qihai(CV6) meridian points during Qigong state, the change of magnetic field around acupoints Yintang, Laogong points has been measured using 40-Channel DROS-SQUID apparatus. After smoothing process of the continuously measured magnetic signal around acupoints for a few minutes, we could observe that a series of peaks, magnitude of -1.0~2.5pT appeared. But there was no significant difference in changes of magnetic signal around acupoints. Physical signals of magnetocardiogram has been measured by using 2-Channel DROS SQUID(Magnetocardiogram). Physical signals of magnetocardiogram were clealy changed at the ST segments after S-wave when qigong master concentrates the Qi.

  • PDF

Clinical diagnostic study on Physiological Signal data measured on 31 cases of lumbago with EAV(Electro-puncture According to Voll) (요통환자(腰痛患者) 31례(例)에 대(對)한 EAV측정치(測定値)의 진단적(診斷的) 고찰(考察))

  • Han, Sang-Gyun;Ha, Chi-Hong;Kim, Jae-Hong;Cho, Myung-Rae;Bae, Eun-Jeong;Shin, Young-Il;Yang, Ki-Yong;Hwang, Kyu-Jung;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.19 no.1
    • /
    • pp.101-110
    • /
    • 2002
  • Background and Purpose : Most diagnostic method for lumbago were invasive and complex. So we need to simplify and objectify diagnostic method for lumbago. Some study with EAV which is one of Physiological Signal Measuring Instruments, report significantly result as objective diagnostic method for other clinical symptom. By using EAV, we have obtained some physiological signal data from meridian-acupoints of 31 lumbago cases. Objective and Methods : This study researched into the clinical statistics for 31 case who ware in lumbago, and they ware treated with oriental medical care at the Dong-shin university oriental hospital during 6 month from June 1 2001 to November 10 2001. The data were analyzed and interpreted to compare with traditional differentiation of symptom-complexes, then further evaluated as the Five Evolutive Phases to make them differentiated. The EAV valus of Five Evolutive Phases were identified with the sequence of wood(木), fire(火), earth(土)steel(金), water(水). Results and Conclusion : These values of physiological signal were identical with standard differentiation of symptom-complexes of lumbago which is the main cause of deficiency of Qi and blood of the kidney and bladder. Among Five Evolutive Phases, Earth and wood values were increased, steel, fire and water were decreased significantly. This data imply the possibility of somewhat generalization from measuring instruments.

  • PDF

Clinical Study of Discrimination of Sasang Constitution wi th 7-Zone-Diagnostic System(VEGA-DFM722) (7구역진단기(VEGA-DFM722)를 이용한 사상체질 판별 가능성에 대한 임상 연구)

  • Song, Beom-Yong;Kwon, Kyong-Suk;Song, Jeong-Mo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.82-93
    • /
    • 2007
  • 1. Objectives Functional medicine is a system which utilizes certain Investigative and treatment methods that are primarily oriented toward the recognition of functional disorder. The 7-zone-diagnostic system(VEGA-DFM722 and ABR-2000, etc) is a diagnostic device which applies pulse signals to predetermined bodily locations. We think that we can discriminate between Soeumin, Soyangin and Taeumin with this system. 2. Methods The subject of our study is no disease men and women who are decided the same constitution both survey of the QSCC II and diagnosis of specialist of the Sasang Constitution. All subject are 76(Soeumin(N=24), Soyangin(N=17), Taeumin(N=35)) cases. We make an analysis of a distinctive feature on the result of the VEGA-DFM722. 3. Results and Conclusions 1) Soeumin or Taeumin women had that the red bar graphs of and 1, 2 and 3 are lower than the red bar graphs of zone 4, 5, 6 and 7 in factor AA on the result of the VEGA-DFM722 with the naked eye. Soyangin or Taeumin men had that the red bar graphs of zone 1,2 and 3 are higher than the red bar graphs of tone 4, 5, 6 and 7 in factor AA on the result of the VEGA-DFM722 with the naked eye. 2) The typical discrimination between Soeumin and Soyangin showed statistical significance(p<0.05) in Factor PF 4(red bar) on the result of VEGA-DFM722.

  • PDF