• 제목/요약/키워드: Electricity Supply

검색결과 650건 처리시간 0.029초

심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석 (Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater)

  • 정훈;황성욱;이철희
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.

The Role of Nuclear Power in Korea under Carbon Emissions Regulation

  • Lee, Man-Ki;Kim, Seung-Su;Moon, Kee-Hwan
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(2)
    • /
    • pp.651-656
    • /
    • 1997
  • Efforts are made to examine the role nuclear energy under the international carbon emissions regulation. To do so, an econometric model for energy demand and supply is developed. Here, several scenarios on the regulation are assumed and then each scenario is analyzed by using this model. This model also makes it Possible to analyze the effect of carbon tax. The results show that share nuclear increases up to 60% in 2020 Instead 45% makes GDP rise by 1.9% while the electricity price lower by 46% in carbon emission regulation.

  • PDF

국내 풍력발전 설비의 이용률과 용량크레딧 분석 (Analysis of Capacity Factors and Capacity Credits for Wind Turbines Installed in Korea)

  • 백천현
    • 한국태양에너지학회 논문집
    • /
    • 제39권4호
    • /
    • pp.79-91
    • /
    • 2019
  • The capacity credit (CC) is a key metric for mid- to long-term power system capacity planning. The purpose of this study is to estimate the CCs of domestic wind turbines. Based on hourly capacity factor (CF) data during the seven years from 2011 to 2017, the new so-called probabilistic CF scheme is introduced to effectively reflect the variability of CFs on CC estimation. The CCs are then estimated through the CF-based method and the ELCC (Effective Load Carrying Capability) method reflecting the probabilistic CF scheme, and the results are compared. The results show that the CC value 0.019 for domestic wind turbines proposed in the $8^{th}$ Basic Plan for Electricity Supply and Demand corresponds to the CC with a confidence level slightly lower than 95%.

중국 석탄산업의 경제적 효과 분석

  • 최정석
    • 중국학논총
    • /
    • 제71호
    • /
    • pp.151-167
    • /
    • 2021
  • Looking at the economic effects of the Chinese coal industry analyzed in this text, the following results could be drawn. First, according to the analysis result of the influence coefficient of the Chinese coal industry in 2017, it is mainly rural and regional development It was analyzed that it had a great influence on the necessary sectors. Second, the sensitivity coefficient of the Chinese coal industry in 2017 was presented in the order of electricity and heat production and supply, monetary finance and other financial services, business services, refined petroleum and nuclear fuel processing products, wholesale business, and retail business. It is judged that this is more influenced by government policy than by influence coefficient.

Optimal Siting of UPFC for Reducing Congestion Cost by using Shadow Prices

  • Lee, Kwang-Ho;Moon, Jun-Mo
    • KIEE International Transactions on Power Engineering
    • /
    • 제11A권4호
    • /
    • pp.21-26
    • /
    • 2001
  • As competition is introduced in the electricity supply industry, congestion becomes a more important issue. Congestion in a transmission network occurs due to an operating condition that causes limit violations on the transmission capacities. Congestion leads to inefficient use of the system, or causes additional costs (Congestion cost). One way to reduce this inefficiency or congestion cost is to control the transmission flow through the installation of UPFC (Unified Power Flow Controller). This paper also deals with an optimal siting of the UPFC for reducing congestion cost by using shadow prices. A performance index for an optimal siting is defined as a combination of line flow sensitivities and shadow prices. The proposed algorithm is applied to the sample system with a condition, which is concerning the quadratic cost functions. Test results show that the siting of the UPFC is optimal to minimize the congestion cost by the proposed algorithm.

  • PDF

The Environmental and Economic Impact of Trade between South Korea and the United States

  • Tae-Jin Kim;Nikolas Tromp
    • East Asian Economic Review
    • /
    • 제28권1호
    • /
    • pp.37-67
    • /
    • 2024
  • This paper analyses carbon emissions and value-added embodied in trade between two large developed countries, South Korea and the United States, during 2000-2014. Using multi-regional input-output (MRIO) tables, our analysis reveals that carbon emissions and value-added embodied in exports grew by 19% and 101% for South Korea but shrank by 43% and 7% for the United States. As a result, South Korea experienced a 40% increase in net carbon exports and 243% increase in net value-added exports. At the industry level, the primary drivers of changes in carbon exports were electricity and basic materials. The majority of industries in witnessed improvements in carbon intensities suggesting improved environmental efficiency. While both countries achieved a decoupling of carbon emissions from value-added exports, substantial year-to-year and sectoral variations were observed. Finally, structural decomposition analysis indicates that domestic supply-side factors played a role in decreasing emissions whereas foreign demand-side factors contributed to emissions increases. In line with the main findings, various implications for policy and future research are discussed.

산림 바이오매스의 에너지 활용을 위한 타당성 분석 (The feasibility analysis for energy utilization of forest biomass)

  • 강현구;박기철;김래현
    • 에너지공학
    • /
    • 제23권1호
    • /
    • pp.7-20
    • /
    • 2014
  • 본 연구에서는 전국적으로 48만ha에 걸쳐 연료림으로 조성되어 있는 리기다소나무를 에너지연료로 활용하기 위해 최적의 생산시스템을 개발하고 이에 따른 공급가격과 전기 열 판매가격 및 이용률 등을 고려한 우드칩 연료한계가격을 산출하였으며 다양한 시나리오에 따른 경제성 민감도 분석을 수행하였다. 열 및 발전 전용시설에서의 경제성을 결정짓는 가장 중요한 변수는 연료공급가격이다. 열 전용시설에서는 본 연구에서 제안된 모든 생산시스템에서 생산되는 우드칩 연료의 활용이 가능하며 발전 전용시설에서는 생산비가 가장 높은 연료사용에는 일부 한계가 있으나 전기 판매가격이 현재의 SMP(pitch pine : 계통한계가격)보다 높아지거나 이용률이 80%이상으로 되는 경우 모두 활용 가능한 것으로 분석되었으며, 더욱이 RPS제도 시행에 따른 신재생에너지 인증서(REC:Renewable Energy Certificate)편익과 온실가스 절감효과로 CDM(Clean Development Mechanism)편익 등을 고려할 경우 충분히 활용 가능한 것으로 분석되었다. 따라서, 국내 발전부문에서의 RPS 공급의무율 이행을 위해서 산림 바이오매스의 활용이 적극 권장된다.

One sensor방식의 추적식 PV System (The Tracking Photovoltaic System by One sensor Type)

  • 고재홍;박정민
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4733-4739
    • /
    • 2012
  • 본 논문에서는 태양과 태양전지 모듈이 법선을 이루도록 기존에 태양의 방위각 및 고도각을 제어하는 양축 추적시스템에 2개의 센서를 사용하였던 Double-sensor방식에서 1개의 센서로 방위각 및 고도각을 제어할 수 있는 One-sensor방식의 양축 추적시스템을 제안하였다. 그리고 제안한 추적시스템을 제작하여 시스템의 실제 운전을 실행하였다. 제안한 추적시스템은 1개의 센서를 이용하여 태양이 항상 법선을 이루면서 태양전지 모듈에 입사되게 제어하기 위해 방위각과 고도각을 제어하는 양축 추적시스템이다. 실험결과 가장 효율적인 운전과 불필요한 구동부의 동작을 방지하여 전력소모를 감소할 수 있었으며 고정식에 비해 본 논문에서 제안한 One-sensor방식의 양축 추적시스템이 약 23[%]의 발전효율이 증가함을 확인 할 수 있었다. 태양을 추적하여 더 많은 햇빛을 받게 하여 태양전지의 효율을 높이기 위하여 행해진 추적장치는 대형 방식에 많은 연구가 진행되어 왔다. 따라서 본 논문의 태양위치추적의 모니터링 시스템을 구축하여 지속적인 발전효율에 대한 실용화 연구를 통해 태양광발전시스템 보급에 큰 역할을 할 것이라 기대된다.

수소액화공정에서 LNG 냉열 적용에 관한 시뮬레이션 연구 (Simulation Study on the Application of LNG Cold Energy for Hydrogen Liquefaction Process)

  • 한단비;변현승;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제31권1호
    • /
    • pp.33-40
    • /
    • 2020
  • As hydrogen utilization becomes more active recently, a large amount of hydrogen should be supplied safely. Among the three supply methods, liquefied hydrogen, which is an optimal method of storage and transportation convenience and high safety, has a low temperature of -253℃, which is complicated by the liquefaction process and consumes a lot of electricity, resulting in high operating costs. In order to reduce the electrical energy required for liquefaction and to raise the efficiency, hydrogen is cooled by using a mixed refrigerant in a precooling step. The electricity required for the precooling process of the mixed refrigerant can be reduced by using the cold energy of LNG. Actually, LNG cold energy is used in refrigeration warehouse and air liquefaction separation process, and a lot of power reduction is achieved. The purpose of this study is to replace the electric power by using LNG cold energy instead of the electric air-cooler to lower the temperature of the hydrogen and refrigerant that are increased due to the compression in the hydrogen liquefaction process. The required energy was obtained by simulating mixed refrigerant (MR) hydrogen liquefaction system with LNG cold heat and electric system. In addition, the power replacement rate of the electric process were obtained with the pressure, the temperature of LNG, the rate of latent heat utilization, and the hydrogen liquefaction capacity, Therefore, optimization of the hydrogen liquefaction system using LNG cold energy was carried out.

ASPEN PLUS®를 이용한 태양열 유기랭킨사이클 열병합 발전시스템의 공동주택 적합도 분석 (Feasibility of a Solar Thermal Organic Rankine Cycle Power Plant for an Apartment Complex with Aspen Plus®)

  • 임석연;김형근;유상석
    • 대한기계학회논문집B
    • /
    • 제39권4호
    • /
    • pp.317-324
    • /
    • 2015
  • 본 연구에서는 아파트단지에 적용되는 태양열 급탕 시스템의 에너지 활용도를 높이기 위해 유기랭킨사이클을 적용하여 해석적 연구를 수행하였다. 시스템 해석은 Aspen $Plus^{(R)}$을 활용하였으며 태양열집열기는 급탕 온도와 유기랭킨 사이클의 운전 조건을 고려하여 진공관형 집열기를 적용하였다. R134a, R141a, R245fa 등의 냉매를 작동유체로 선정하였으며, 시스템 성능해석을 통하여 R245fa 냉매가 적용가능성이 가장 높게 나타났다. 비가역성 해석과 민감도 해석을 통해 유기랭킨 사이클 시스템의 효율 및 성능 확보를 위해서는 증발기와 터빈에 대한 기술 개발이 매우 중요하다는 것을 밝혀냈으며, 순수 급탕으로만 활용하는 시스템에 전기 생산 설비를 추가하게 되면 약 50%의 추가적인 경제성이 확보됨을 확인하였다.