• 제목/요약/키워드: Electrical therapy

검색결과 613건 처리시간 0.027초

일정한 약물 투여를 통한 HIV 환자의 long-term non-progressor 전환 치료 (Treatment to induce long-term non-progressor with constant drug dosage)

  • 김진영;김원희;고지현;정정주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2233-2235
    • /
    • 2004
  • This paper presents a therapy that uses a constant drug dosage for leading a HIV patient to a LTNP (Long-Tenn Non-Progressor). From analysis of CTLp (Cytotoxic T Lymphocyte precursor) concentration at equilibrium point and bifurcation of equilibrium points, we found the therapy with a drug whose efficacy is less than one brings higher CTLp concentration at the equilibrium point. From this fact, we propose a treatment with constant drug dosage. which can induce LTNP.

  • PDF

경피신경전기자극과 미세전류자극이 정상인의 교감신경 긴장도에 미치는 영향 (The Effects of Transcutaneous Electrical Nerve Stimulation and Microampere Electrical Nerve Stimulation on Sympathetic Tone in Healthy Subjects)

  • 박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제9권1호
    • /
    • pp.51-57
    • /
    • 1997
  • The purpose of this study was to determine the effect of two different forms of transcutaneous electrical nerve stimulation(TENS) and one of microcurrent high voltage pulsed galvanic current(HVPC) on sympathetic tone in healthy subjects. Fourty subjects received TENS(20) and PVPC(30) during short time(20min). Left finger tip skin temperatures were measured at four interval for each treatment : 1) before treatment, 2) after 10 minutes treatment, 3)after 20 minutes treatment, and 4) after 10 minutes rest. The results were as follows. 1) TENS treatment group increased skin temperature after treatment 20 minutes, but HVPC treatment increased akin temperature after 10 minutes and recovered normal skin temperature after 10 minutes treatment. It means that short time(20min) electrical stimulation decreased sympathetic activities. 2) Sympathetic activities of TENS stimulation were influenced by age, but HVPC were not. 3) During 10 minutes, both treatment increased sympathetic activities, but HVPC treatment reversed sympathetic activity more rapidly than TENS. 4) The changes of skin temperature means by sex, males in TENS treatment group were higher than females, but HVPC were reverted.

  • PDF

Electrical Acupuncture Combined Bee Venom Therapy for Pain and Disability Induced Intervertebral Herniated Disc of L-spine;A Pilot Study

  • Kwon, Young-Dal
    • 동의생리병리학회지
    • /
    • 제22권3호
    • /
    • pp.703-707
    • /
    • 2008
  • To examine the efficacy of electrical acupuncture combined bee venom in controlling low back with leg pain induced Herniated Intervertebral Disc (HIVD). 13 patients (men 8, women 5; age $41.30\;{\pm}\;17.27$) diagnosed as HIVD by CT or MRI had low back and leg pain as a chief complaint and diseases such as spinal tumor, infection and fracture were excluded. They were treated by electrical acupuncture (8 Hz) combined bee venom therapy three times a week in Wonkwang University Hospital, and pain intensity with VAS and functioning with Roland-Morris Disability Qestionnaire(RDQ) were measured at the baseline(B), and 4 weeks after treatment. The data were analyzed with Wilcoxon signed ranks test(SPSS12.0) and the level set for statistical significance was P<0.05. The pain was significantly reduced by two combined treatments (=0.002;$B7.69{\pm}2.06$,4Wks$4.70{\pm}2.72$). The function was also significantly improved by both treatments(=0.001;$B12.15{\pm}6.85$,4Wks$6.85{\pm}5.15$). The results suggest that a combination of acupuncture and bee venom therapy may be beneficial for low back pain from HIVD. In future, randomized clinical trials including follow-up are needed to examine the effects of these therapies.

뇌졸중 유발 백서모델에서 환경강화와 말초신경전기자극이 중추신경계의 신경성장인자에 미치는 영향 (The Effects of Nerve Growth Factor Expression of Central Nerve System by Environmental Enrichment and Peripheral Nerve Electrical Stimulation in Brain Ischemia Model Rats)

  • 김사열;김은정;김계엽
    • The Journal of Korean Physical Therapy
    • /
    • 제19권4호
    • /
    • pp.33-41
    • /
    • 2007
  • Purpose: To investigate environmental enrichment and nerve stimulation follows in application times with the change of BDNF & Trk-B receptor in the motor cortex and spinal cord. Methods: Experimental groups were divided into the five groups. Group I: normal control group, Group II: experiment control group, Group III: sciatic never electrical stimulation after MCAO, Group IV: application of only environmental enrichment after MCAO, Group V: never electrical stimulation with environmental enrichment after MCAO. Histologic observation and coronal sections were processed individually in goat polyclonal antibody phosphorylated BDNF and rabbit polyclonal antibody Trk-B receptor. Results: In immunohistochemistric response of BDNF and Trk-B, group II were showed that lower response effect at postischemic 1 days, 3 days, and 7 days. Group V were showed that increase response effect at postischemic 3 days, 7 days and 14 days. Specially showed that the most response effect at postischemic 14 days. In neurobehavioral assessment, group V were significantly difference from other groups on between-subject effects. Conclusion: The above results suggest that combined environmental enrichment with peripheral nerve electrical stimulation in focal ischemic brain injury were more improved that the change of BDNF & Trk-B receptor expression than non treatment.

  • PDF

적외선 레이저 다이오드가 콜라겐 형성에 미치는 영향 (The effect of infrared rays diode irradiation on collagen formation)

  • 김태곤;김영표;이호식;박용필;천민우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.411-411
    • /
    • 2009
  • Low level laser therapy has various therapy effects. This paper performed the basic study for developing the Low Level Laser Therapy Equipment for medical treatment. The apparatus has been fabricated using the laser diode and microprocessor unit. This equipment was fabricated using a micro-controller and a laser diode, and designed to enable us to control light irradiation time, frequency and so on. In this study, the designed device was used to find out how infrared laser diode affected the collagen formation. For in-vivo test, a round wound 1cm in diameter was cut from the test animal whose epidermal and dermal layers were removed. Test animals were relieved for 24 hours after wounds had been excised and then the infrared laser irradiation group was given irradiation therapy over 9 days one 20 min per day. As a result, More collagenosis occurred in the order of infrared laser irradiation and non-irradiation group. Collagenosis is closely related to wound repair and it was found that infrared laser irradiation groups had more collagenosis and was quicker to recover from wound than non-irradiation group.

  • PDF

Effects of Functional Electrical Stimulation Intensity Level on Corticomuscular Coherence during Action Observation

  • Kim, Ji Young;Noh, Hyunju;Park, Jiwon
    • The Journal of Korean Physical Therapy
    • /
    • 제32권5호
    • /
    • pp.307-311
    • /
    • 2020
  • Purpose: This study examined the effects of changes in the intensity of Functional Electrical Stimulation (FES) on CorticoMuscular Coherence (CMC) during action observation. This paper presents a neurophysiological basis for the effective intensity of FES. Methods: Twenty-seven healthy volunteers were asked to observed a video with FES. The FES was provided with a sensory stimulation level, nerve stimulation level, and motor stimulation level. Simultaneously, an electroencephalogram (EEG) of the sensorimotor cortex and electromyogram (EMG) from the wrist extensor muscle were recorded. The peak CMC and average CMC were analyzed to compare the differences caused by the FES intensity. Results: The peak CMC showed a significant increase in the alpha band during motor stimulation (p<0.05). The average CMC showed a significant increase in the beta band during motor stimulation (p<0.05). Conclusion: The intensity of FES, which causes actual movement, increased the CMC during action observation. These results show that the intensity of the FES can affect the functional connection between the sensorimotor cortex and muscle.

고관절 등척성 내전 운동과 슬관절 등척성 신전운동시 대퇴사두근의 활동전위에 미치는 효과 (Isometric Hip Adduction Exercise and Isometric Knee Extension Exercise Effect on Action Potentials of the Quadriceps Femoris)

  • 김명진;이진섭;이영미;김영록
    • 한국전문물리치료학회지
    • /
    • 제2권1호
    • /
    • pp.36-43
    • /
    • 1995
  • The purpose of this study was to determine whether the vastus medialis oblique muscle(VMO) had greater electrical activity than the vastus lateralis muscle(VL) when hip adduction and knee extension exercise were performed. Electrical activity of the VMO and VL was measured on 42 healthy subjects (28 men, 14 women) during maximal voluntary isometric contractions of hip adduction and knee extension by an EMG-BIOFEEDBACK. The results showed that the electromyographic activity of the VMO was significantly greater than that of the VL during the hip adduction exercise. Differences noted with knee extension by performing hip adduction exercises. Isometric hip adduction exercises, therefore, may be advisable in the treatment of patients with patellofemoral pain.

  • PDF

신경근전기자극에 의한 경직근의 최대 등척성 수축력 변화 (Change of the Maximal Isometric Contraction to the Spastic Muscle by NMES)

  • 임상완;이정우;김태열;송명수;최은영
    • 대한임상전기생리학회지
    • /
    • 제2권3호
    • /
    • pp.25-35
    • /
    • 2004
  • The purpose of this study was compared to MTICs(maximal tolerated isometric contraction), decrement and recovery. For this, using isokinetic exercise analysis device(Biodex Medical Systems Inc., Biodex System 3PRO, USA), low rate(20 Hz) and high rate(100 Hz) NMES(neuromuscular electrical stimulation) were applied to the quadriceps muscles of fifteen patients with spastic hemiplegia caused by lesions in the central nervous system. The results were as follows: 1. It was shown to fast decrement in the middle of phase at low rate NMES and to slow decrement of MTIC response at high rate NMES(p<.01). 2. It was shown to fast recovery at high rate NMES and to slow recovery at low rate NMES in recovery tendency of MTIC(p<.01). These conclusions suggest that NMES of high rate caused to slow fatigue and fast recovery different from low rate NMES.

  • PDF

전기자극이 근기능 변화에 미치는 효과 (Effects of Electrical Stimulation on Muscle functional Change)

  • 정호발;고태성
    • 대한물리치료과학회지
    • /
    • 제9권4호
    • /
    • pp.105-112
    • /
    • 2002
  • When any damage or disease occurs, muscular strength and muscular endurance are lowered, and thus, if one is able to be restored from the damage or the disease, appropriate stimulus is required, since the muscles have to restore their proper functions. For such stimulus, the way of exercising and the way using electric stimulus are used in physical therapy. In order to examine the change in muscular strength, muscular endurance and girth of limbs for Biceps brachii, according to the lands of stimulus, in this article a total of 42 healthy male and female adults in their twenties were randomly sampled, and a series of tests were conducted for 6 weeks, for 15 minutes per once, 3 times per week, respectively, dividing them into the group for RUS(Russian Current Stimulation), PRE(Progressive Resistive Exercise) and P+R(RUS + PRE). The findings showed that the change in muscular strength was most significant as for the group for P+R, since it increased from $62.12{\pm}25.30$ before experiment to $95.78{\pm}34.07$ after 6 weeks: the change in muscular endurance was most significant as for the group for P+R, since it increased from $17.57{\pm}6.63$ to $42.86{\pm}10.24$; and the change in the girth of limbs was slightly significant only in the group for P+R, and the remaining two groups showed no significance.

  • PDF

의료용 4ch 광 조사 발진기 개발 (Development of 4ch Light Irradiator for Medical Therapy)

  • 천민우;김성환;문성표;박용필;김태곤;박노봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.480-480
    • /
    • 2007
  • This paper performed the basic study for developing the light therapy equipment for medical treatment. We developed the equipment for medical therapy using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled, stage by stage.

  • PDF