• Title/Summary/Keyword: Electrical test

Search Result 7,386, Processing Time 0.039 seconds

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Dependency of Compatibility Termination Criteria on Prehydration and Bentonite Quality for Geosynthetic Clay Liners (사전투수 및 벤토나이트 품질에 따른 GCL의 투수종결기준에 미치는 영향평가)

  • Lee Jae-Myung;Shackelford Charles D.;Choi Jae-Soon;Jung Moon-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.141-158
    • /
    • 2004
  • The dependency of criteria used to terminate compatibility tests on the prehydration and quality of bentonite in geosynthetic clay liners (GCLs) is evaluated based on permeation with chemical solutions containing 5, 10, 20, 50, and 100 mM calcium chloride ($CaCl_2$). The hydraulic conductivity tests are not terminated before chemical equilibrium between the effluent and the influent chemistry has been established, resulting in test durations ranging from < 1 day to > 900 days, with longer test durations associated with lower $CaCl_2$ concentrations. The evaluation includes both physical termination criteria (i.e., volumetric flow ratio and steady hydraulic conductivity based on ASTM D 5084, ${\ge}2$ pore volumes of flow, constant thickness of specimen) and chemical termination criteria requiring equilibrium between influent and effluent chemistry (viz., electrical conductivity, pH, and $Ca^{2+}\;and\;Cl^-$ concentrations). For specimens permeated with 5, 10, and 20 mM $CaCl_2$ solutions, only the criterion based on chemical equilibrium in $Ca^{2+}$ concentration correlates well with equilibrium in hydraulic conductivity, regardless of prehydration or quality of bentonite. However, all of the termination criteria, except for the volumetric flow ratio and 2 pore volumes of flow for the prehydrated specimens, correlate well with equilibrium in hydraulic conductivity regardless of prehydration or quality of bentonite when permeated with 50 and 100 mM $CaCl_2$ solutions. The results illustrate the uniqueness of the termination criterion based on solute concentration equilibrium between the effluent and the influent with respect to both prehydration and quality of bentonite in the GCLs.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices: Dental X-ray Equipment (치과용엑스선장치의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Lee, Jun-Ho;Park, Chang-Won
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.651-660
    • /
    • 2016
  • Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

Groundwater Flow Analysis in Fractured Rocks Using Zonal Pumping Tests and Water Quality Logs (구간양수시험과 수질검층자료에 의한 균열암반내 지하수 유동 분석)

  • Hamm, Se-Yeong;Sung, Ig-Hwan;Lee, Byeong-Dae;Jang, Seong;Cheong, Jae-Yeol;Lee, Jeong-Hwan
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.411-427
    • /
    • 2006
  • This study aimed to recognize characteristics of groundwater flow in fractured bedrocks based on zonal pump-ing tests, slug tests, water quality logs and borehole TV camera logs conducted on two boreholes (NJ-11 and SJ-8) in the city of Naju. Especially, the zonal pumping tests using sin91e Packer were executed to reveal groundwater flow characteristics in the fractured bedrocks with depth. On borehole NJ-11, the zonal pumping tests resulted in a flow dimension of 1.6 with a packer depth of 56.9 meters. It also resulted in lower flow dimensions as moving to shallower packer depths, reaching a flow dimension of 1 at a 24 meter packer depth. This fact indicates that uniform permissive fractures take place in deeper zones at the borehole. On borehole SJ-8, a flow dimension of 1.7 was determined at the deepest packer level (50 m). Next, a dimension of 1.8 was obtained at 32 meters of packer depth, and lastly a dimension of 1.4 at 19 meters of packer depth. The variation of flow dimension with different packer depths is interpreted by the variability of permissive fractures with depth. Zonal pumping tests led to the utilization of the Moench (1984) dual-porosity model because hydraulic characteristics in the test holes were most suitable to the fractured bedrocks. Water quality logs displayed a tendency to increase geothermal temperature, to increase pH and to decrease dissolved oxygen. In addition, there was an increasing tendency towards electrical conductance and a decreasing tendency towards dissolved oxygen at most fracture zones.

Effects of acid-treatment conditions on the surface properties of the RBM treated titanium implants (산-처리 조건이 RBM처리한 티타늄 임플란트의 표면 특성에 주는 영향)

  • Lee, Han-Ah;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.257-274
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of acid-treatment conditions on the surface properties of the RBM (Resorbable Blast Media) treated titanium. Disk typed cp-titanium specimens were prepared and RBM treatments was performed with calcium phosphate ceramic powder. Acid solution was mixed using HCl, $H_2SO_4$ and deionized water with 4 different volume fraction. The RBM treated titanium was acid treated with different acid solutions at 3 different temperatures and for 3 different periods. After acid-treatments, samples were cleaned with 1 % Solujet solution for 30 min and deionized water for 30 min using ultrasonic cleanser, then dried in the electrical oven ($37^{\circ}C$). Weight of samples before and after acid-treatment were measured using electric balance. Surface roughness was estimated using a confocal laser scanning microscopy, crystal phase in the surface of sample was analyzed using X-ray diffractometer. Surface morphology and components were evaluated using Scanning Electron Microscope (SEM) with Energy Dispersive X-ray spectroscopy (EDX) and X-ray Photoemission Spectroscopy (XPS). Values of the weight changes and surface roughness were statistically analyzed using Tukey-multiple comparison test (p=0.05). Weight change after acid treatments were significantly increased with increasing the concentration of $H_2SO_4$ and temperature of acid-solution. Acid-treatment conditions (concentration of $H_2SO_4$, temperature and time) did not produce consistent effects on the surface roughness, it showed the scattered results. From XRD analysis, formation of titanium hydrides in the titanium surface were observed in all specimens treated with acid-solutions. From XPS analysis, thin titanium oxide layer in the acid-treated specimens could be evaluated. Acid solution with $90^{\circ}C$ showed the strong effect on the titanium surface, it should be treated with caution to avoid the over-etching process.

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

Feasibility Study on the Fault Tree Analysis Approach for the Management of the Faults in Running PCR Analysis (PCR 과정의 오류 관리를 위한 Fault Tree Analysis 적용에 관한 시범적 연구)

  • Lim, Ji-Su;Park, Ae-Ri;Lee, Seung-Ju;Hong, Kwang-Won
    • Applied Biological Chemistry
    • /
    • v.50 no.4
    • /
    • pp.245-252
    • /
    • 2007
  • FTA (fault tree analysis), an analytical method for system failure management, was employed in the management of faults in running PCR analysis. PCR is executed through several processes, in which the process of PCR machine operation was selected for the analysis by FTA. The reason for choosing the simplest process in the PCR analysis was to adopt it as a first trial to test a feasibility of the FTA approach. First, fault events-top event, intermediate event, basic events-were identified by survey on expert knowledge of PCR. Then those events were correlated deductively to build a fault tree in hierarchical structure. The fault tree was evaluated qualitatively and quantitatively, yielding minimal cut sets, structural importance, common cause vulnerability, simulation of probability of occurrence of top event, cut set importance, item importance and sensitivity. The top event was 'errors in the step of PCR machine operation in running PCR analysis'. The major intermediate events were 'failures in instrument' and 'errors in actions in experiment'. The basic events were four events, one event and one event based on human errors, instrument failure and energy source failure, respectively. Those events were combined with Boolean logic gates-AND or OR, constructing a fault tree. In the qualitative evaluation of the tree, the basic events-'errors in preparing the reaction mixture', 'errors in setting temperature and time of PCR machine', 'failure of electrical power during running PCR machine', 'errors in selecting adequate PCR machine'-proved the most critical in the occurrence of the fault of the top event. In the quantitative evaluation, the list of the critical events were not the same as that from the qualitative evaluation. It was because the probability value of PCR machine failure, not on the list above though, increased with used time, and the probability of the events of electricity failure and defective of PCR machine were given zero due to rare likelihood of the events in general. It was concluded that this feasibility study is worth being a means to introduce the novel technique, FTA, to the management of faults in running PCR analysis.

Influences of Silicate Fertilizer Application on Soil Properties and Red Pepper Productivity in Plastic Film House (규산질비료가 시설재배지 토양특성과 고추수량에 미치는 영향)

  • Ahn, Byung-Koo;Han, Soo-Gon;Kim, Jong-Yeob;Kim, Kab-Cheol;Ko, Do-Young;Jeong, Seong-Soo;Lee, Jin-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.254-261
    • /
    • 2014
  • BACKGROUND: This study was conducted to investigate effects of silicate fertilizer application on red pepper (Capsicum annuum L.) productivity with improving soil chemistry under plastic film house in paddy field. METHODS AND RESULTS: The silicate fertilizer was applied as 0, 100, 200, and 300 kg/10a as basal dressing before transplanting pepper plant seedlings. Cultivar of the pepper plant was Cheon-Ha-Dae-Se. Amounts of inorganic fertilizer applied as $N-P_2O_5-K_2O$=19.0-6.4-10.1kg/10a was estimated depending on soil test values. After applying 50% of nitrogen, 100% of phosphorus, and 60% of potassium fertilizers as basal dressing, the seedlings of pepper plant were transplanted. The rests of nitrogen and potassium fertilizers were applied as side-dressing after the first, second, and fourth harvests of red pepper. When comparing selected chemical properties of soils between before transplanting and after final(the fifth) harvest, soil pH, available $P_2O_5$, and exchangeable $Ca^{2+}$ increased with increasing the applications of silicate fertilizer, whereas electrical conductivity(EC) decreased. However, exchangeable $K^+$ was higher with the treatments of 100 and 200 kg/10a, and exchangeable $Mg^{2+}$ was higher with 300 kg/10a application. In addition, nitrogen and phosphorus concentrations of red pepper collected from the first harvesting stage decreased with increasing the applications of silicate fertilizer, but potassium, calcium, and magnesium concentrations in red pepper were highest with 300 kg/10a application. Yield of red pepper increased between 9.0 and 11.8% with the applications of silicate fertilizer. Marketable fruit rate of res pepper was highest(97.3%) with 200 kg/10a application. CONCLUSION: The application of silicate fertilizer as basal dressing in paddy-converted fields improved soil chemistry and increased red pepper productivity.

Effects on Water Quality and Rice Growth to Irrigation of Discharge Water from Municipal Waste Treatment Plant in Rice Paddy during Drought Periods (한발기 벼 재배시 하수종말처리장 방류수 관개에 따른 논의 수질 및 벼 생육에 미치는 영향)

  • Shin, Joung-Du;Lee, Jong-Sik;Kim, Won-Il;Jung, Goo-Bok;Kim, Jin-Ho;Yun, Sun-Gang;Choi, Chul-Mann
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.225-230
    • /
    • 2008
  • Objective of this study was to access the environmental impacts of the use of discharge water from municipal waste water treatment plant as alternative irrigation resources during drought season for rice cultivation. For the field experiments, it was observed that plant growth and yield characteristics at 20 days of alternative irrigation period with application of FAST (fertilizer application based on soil test) 50% were relatively the same as the control. For the surface water quality, it appeared that $EC_i$ (electrical conductivity of irrigation water) and SAR (sodium adsorption ratio) values of DMWT (discharge waters from municipal wastewater treatment plant) irrigation were twofold higher than those of ground water irrigation as the control regardless of fertilization levels. For the irrigation periods, there were not significantly difference between 10 and 20 days of treatments, but $EC_i$ and SAR values of surface water were highest at 30 days of irrigation periods at initial rice growing stages. Generally, $EC_i$ values of percolation water in all the treatments were gradually increasing until 30days after irrigation, and then decreasing to harvest stage. Overall, it might be considered that there was possibility to irrigate DMWT with application of FAST 50% for 20 days of drought periods at rice transplanting season. Furthermore, efficiency rate of alternative irrigation water for 20 days of drought period was 32.7% relative to the total annual irrigation water for rice cultivation.