The Survey of Domestic and Foreign for On-Line Monitoring System at Low Voltage Facilities (저전압 전기설비의 온라인 감시시스템 구축을 위한 국내외 실태조사)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.75-81
    • /
    • 2007
  • In this paper, the survey and the analysis of domestic and foreign for on-line monitoring system at low voltage facilities example for value added service about electrical safety were executed. According to survey, in Japan, they are executing the on-line electrical facilities monitoring in based on IT basic law for the information of society construction and not only electrical safety but also value added service such as alarm for earthquake, security are being done. In USA and Europe using power line communication(PLC), the on-line observation and building district management service were being realized. Observing the domestic case, electrical safety related with service such as distribution panel product incorporating load management and leakage current measurement was being executed in some companies. From the survey, it is necessary to improve on the law and the system for market activity in domestic.

The Development of Infrared Thermal Imaging Safety Diagnosis System Using Pearson's Correlation Coefficient (피어슨 상관계수를 이용한 적외선 열화상 안전 진단 시스템 개발)

  • Jung, Jong-Moon;Park, Sung-Hun;Lee, Yong-Sik;Gim, Jae-Hyeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.55-65
    • /
    • 2019
  • With the rapid development of the national industry, the importance of electrical safety was recognized because of a lot of new electrical equipment are installing and the electrical accidents have been occurring annually. Today, the electrical equipments is inspect by using the portable Infrared thermal imaging camera. but the most negative element of using the camera is inspected for only state of heating, the reliable diagnosis is depended with inspector's knowledge, and real-time monitoring is impossible. This paper present the infrared thermal imaging safety diagnosis system. This system is able to monitor in real time, predict the state of fault, and diagnose the state with analysis of thermal and power data. The system consists of a main processor, an infrared camera module, the power data acquisition board, and a server. The diagnostic algorithm is based on a mathematical model designed by analyzing the Pearson's Correlation Coefficient between temperature and power data. To test the prediction algorithm, the simulations were performed by damaging the terminals or cables on the switchboard to generate a large amount of heat. Utilizing these simulations, the developed prediction algorithm was verified.

A Study on the Effective Utilization Plan through Field Investigation and Analysis with Power Transformers in Domestic Areas

  • Shin, Heung-Sik;Lee, Jae-Cheon;Bai, Seok-Myung;Kim, Seon-Gu;Kim, Jin-Tae;Kim, Gi-Hyeon;Jeong, Jong-Wook;Bang, Seon-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.88-95
    • /
    • 2007
  • Korea is highly dependent on foreign countries for energy while at the same time having a high energy-consumption industrial structure. Therefore, logical improvements in energy use efficiency and nationwide energy saving are becoming more and more important in coping with the worldwidehigh oil prices and environmental issues such as listed in the Kyoto Protocol to the United Nations Framework Convention on Climate Change. Consequently, a study was conducted on the average annual load factor in domestic areas to set a reasonable and reliable technology standard plan for high-efficiency transformers. The average annual load factor in Korea was discovered to be 18.4[%] classified by industry. This factor is expected to be used in arranging a domestic standard for a minimum efficiency system for transformers, and in reviewing and supplementing the standard transformers plan for the High Energy-Efficiency Appliance Certification. The expected effect from the establishment of the technology standards plan for highly efficient transformers is the expansion of the manufacturing and distribution of highly efficient transformers that are suitable for domestic use. These will lead to electricity cost savings for users, strengthening the related industries' market competitive powers and the effective reduction of greenhouse gases on a national level by drastically reducing loss from transformers, which accounts for a large portion of the total electric supply losses.

Development of a Novel Real-Time Monitoring System Algorithm for Fire Prevention (화재예방을 위한 실시간 모니터링 시스템의 알고리즘 개발)

  • Kim, Byeong-Jo;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.47-53
    • /
    • 2014
  • Despite the automatic fire alarm system, according to the national fire data system of national emergency management agency, the fires account for 40,932 incidents, 2,184 injuries and about 430 billion won in property losses in 2013. Since the conventional automatic fire alarm system has several weaknesses related to electrical signal such as noise, surge, lighting, etc. Most fires are mainly caused by electrical faults, mechanical problem, chemical, carelessness and natural. The electrical faults such as line to ground fault, line to line fault, electrical leakage and arc are one of the major problems in fire. This paper describes the development of a novel real-time fire monitoring system algorithm including fault detection function which puts the existing optic smoke and heat detectors for fire detection with current and voltage sensors in order to utility fault monitoring using high accuracy DAQ measurement system with LabVIEW program. The fire detection and electrical fault monitoring with a proposed a new detection algorithm are implemented under several test. The fire detection and monitoring system operates according to the proposed algorithm well.

Research on the Comparison and Application of IEC60364 & NFPA70(NEC) according to WTO/TBT agreement (WTO/TBT 협정에 준한 전기설비의 IEC 60364와 NFPA70(NEC)의 비교적용에 관한 연구)

  • Chung, Young-Ki;Kwak, Hee-Ro;Nam, Taik-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.140-143
    • /
    • 2001
  • As global trade system transferred GATT into WTO, the harmonization of technological standards, certification, construction, testing is the trend of world. This drift is based on WTO / TBT agreement coming. In effect after 12th, April, 1979. For Korea, the distribution system has a strong resemblance to American system so that engineers are confused in adopting standards. IEC60364 and NEC are in part similar but unconvertible because IEC 60364 originated from Europe while NEC originated from USA. This thesis deals with the fundamental elements of electrical safety system with comparing IEC 60364 with NEC. It serves as a guide how to apply standards when engineers select electrical installations.

  • PDF

Assessment of Electrical Safety for Grounding System by Investigation on the Spot (현장조사에 의한 접지시스템의 전기안전성 평가)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.361-364
    • /
    • 2008
  • This paper deals with assessment of electrical safety for grounding system of buildings by investigation on the spot at construction site. The investigation was carried out for grounding method, grounding type, shape of grounding electrode, grounding for lightning protection system, continuity of steelwork in reinforced concrete structure and so on. The investigation on the spot was performed by researcher, engineer with over fifteen years of industry experience all over the country. As a result of investigation on the spot to 13 buildings, common grounding method was dominant. A new grounding system based on international standards includes unity grounding system, structure grounding utilizing steel reinforced concrete, equipotential bonding. use of surge protective device.

  • PDF

Development of Electrical Fire Detection System Applying Fuzzy Logic for Main Causes of Electrical Fire in Traditional Market Shops

  • Kim, Doo Hyun;Hwang, Dong Kyu;Kim, Sung Chul;Kim, Sang Ryull;Kim, Yoon Bok
    • International Journal of Safety
    • /
    • v.11 no.2
    • /
    • pp.15-21
    • /
    • 2012
  • This paper is aimed to develop an electrical fire detection system (EFDS) which can analyze the possibility of electrical fire for overcurrent, leakage current and arc signals of panel board in traditional market shop. The EFDS adopted fuzzy logic and precursory data for overcurrent, leakage current and arc signals to evaluate the possibility of electrical fire. The signals are obtained directly from panel board in traditional market shops and fuzzy membership function is obtained from experiment, simulation, expert's advice. The overcurrent data is acquired by thermal data of normal and abnormal states (partial disconnection) on the insulated electrical wire, in accordance with the increase of the current signal, The leakage current data is obtained under various environments. The arc signal is acquisited by waveforms of instantaneous value in time domain and frequency band in frequency domain. The Fuzzy algorithm for DB of EFDS consists of fuzzification, inference engine by Mamdani's method and defuzzification by center of gravity method. In order to verify the performance and reliability of EFDS, it was applied to Jeon-Ju traditional market shops (90 shops) in Korea. Results show that EFDS in this paper is useful in alarming the fire case, which will prevent severe damage to human beings and properties, and reduce the electrical fires in a vulnerable area of electrical disaster.

Development of Low Voltage Power Cable Fault Diagnosis System (저압용 전력 케이블 결함 진단 장치 개발)

  • Jeon, Jeong-Chay;Kim, Taek-Hee;Choi, Myeong-Il;Kim, Jae-Jin;Yoo, Jae-Gen;Oh, Hun
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.15-16
    • /
    • 2016
  • 본 논문에서는 케이블 결함과 위치를 검출하기 위한 SSTDR(spread spectrum domain reflectomerty) 기반의 진단 장치를 개발하였다. 개발된 진단 장치는 sstdr 기법의 검출 성능을 향상시키기 위해 시간-주파수 상관 분석을 이용하여 기준신호(reference signal)의 상관계수 최댓값 위치를 검출 한 후 기준신호를 제거하여 반사신호의 상관계수의 최댓값 위치를 검출하는 2단계 과정을 갖는다. 개발된 케이블 결함 진단 장치는 실증 시험장을 구축하고, 성능시험을 실시한 결과, ${\pm}1%$ 내 외의 오차를 갖는 것으로 확인되었다.

  • PDF

High Voltage Wiring System Evaluation Methode of FCEV (Fuel Cell Electric Vehicle) (수소연료전지 자동차용 고전압 배선 시스템 평가 기술 개발)

  • Lim, Ji-Seon;Lee, Jeong-Hun;Lee, Hyo-Jeong;Na, Joo-Ran
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.330-336
    • /
    • 2012
  • FCEV uses 250 ~ 450 V instead of using 12 V battery. High voltage vehicle can cause electric shock, fire and explosion accident. Therefore, it has potential factors that can cause hazard of safety for users. United states of America and Europe legislate regulations such as ECE R100, FMVSS 305 for regulating electrical safety during driving or after collision. The company manufacturing high voltage components must do advanced R&D about Method for improving and confirming the safety of high voltage. We develop the specific hardware components of high voltage wiring system for the power train system and power supply system of Hyundai Motors FCEV. This paper shows test method of insulative performance for securing the electrical safety of high voltage components such as power cable, connectors and buss-bar, and proposals the guide line value for human safety of FCEV according to the test result of our development components.

Problems and Improvement Method of Grounding System in Electrical Facilities (건축전기설비에 적용되는 접지시스템 문제점과 개선방안)

  • Chung, Young-Ki;Kwak, Hee-Ro;Shin, Hyo-Sub;Chung, Chun-Byoung;Nam, Taik-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.47-50
    • /
    • 2001
  • Presently the Korean grounding system uses TN system, multi-grounding method with TT independent grounding method. Nevertheless TN system can't exist with TT system in the technological terms. If they coexist, it causes ground-fault circuit not to operate, and brings about different electrical potential rise by customer system. It brings about serious problems for safety. This paper aims for improving method of grounding system based on the technical analysis on instances in foreign countries and Korea. Almost standards and construction manner were apt to be internationalized after WTO/TBT agreement was concluded. The internal grounding systems should meet the international criteria and reliability for safety, and be provided with technologically impeccable standards.

  • PDF