• Title/Summary/Keyword: Electrical recording

Search Result 350, Processing Time 0.042 seconds

A Study On Hardware Design for High Speed High Precision Neutron Measurement (고속 고정밀 중성자 측정을 위한 하드웨어 설계에 관한 연구)

  • Jang, Kyeong-Uk;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.1
    • /
    • pp.61-67
    • /
    • 2016
  • In this paper, a hardware design method is proposed for high speed high precision neutron radiation measurements. Our system is fabricated to use a high performance A/D Converter for digital data conversion of high precision and high speed analog signals. Using a neutron sensor, incident neutron radiation particles are detected; a precision microcurrent measurement module is also included: this module allows for more precise and rapid neutron radiation measurement design. The high speed high precision neutron measurement hardware system is composed of the neutron sensor, variable high voltage generator, microcurrent precision measurement component, embedded system, and display screen. The neutron sensor detects neutron radiation using high density polyethylene. The variable high voltage generator functions as a 0 ~ 2KV variable high voltage generator that is robust against heat and noise; this generator allows the neutron sensor to perform normally. The microcurrent precision measurement component employs a high performance A/D Converter to precisely and swiftly measure the high precision high speed microcurrent signal from the neutron sensor and to convert this analog signal into a digital one. The embedded system component performs multiple functions including neutron radiation measurement for high speed high precision neutron measurements, variable high voltage generator control, wired and wireless communications control, and data recording. Experiments using the proposed high speed high precision neutron measurement hardware shows that the hardware exhibits superior performance compared to that of conventional equipment with regard to measurement uncertainty, neutron measurement rate, accuracy, and neutron measurement range.

Detection of Gastric Contraction in Electrogastrography: Spectrum Analysis and Vector Analysis (위전도에서의 위수축 측정방법 : 주파수영역분석 및 벡터분석)

  • Kim, In-Young;Han, Wan-Taek
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.273-283
    • /
    • 1997
  • Electrogastrography(EGG), the cutaneous recording of the myoelectrical activity of the stomach using surface electrodes, is attactive due to its non-invasiveness. Despite many attempts made over the decades, analysis of surface EGG has not led to identification of contraction-related electrical response activity of the stomach that would help the clinician to diagnose motility disorders of the stomach. We propose feasible methods to detect the gastric contraction by spectrum analysis and vector analysis of the surface EGG signal. A running spectral analysis(RSA) based on the fast Fourier transform (FFT) was applied to the filtered EGG signal. The powers of dominant frequency and its harmonics were compared with gastric contraction signals such as the strain gauge signal from the gastric serosa in dog or the antropyloric pressure in human. And we also carried out vector analysis of the filtered EGG signals obtained from three paired electrodes. The amplitude and direction of the calculated EGG vector were analyzed and compared with the gastric contraction signals. From the spectrum analysis, we found that the increase of the power of the first harmonic of the dominant frequency was highly correlated with the gastric contraction. And from the vector analysis of the EGG signal, we found a typical change of the amplitude and direction of the EGG vector, which can indicate occurrences of the gastric contraction.

  • PDF

Study on Analysis of Queen Bee Sound Patterns (여왕벌 사운드 패턴 분석에 대한 연구)

  • Kim Joon Ho;Han Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.867-874
    • /
    • 2023
  • Recently, many problems are occurring in the bee ecosystem due to rapid climate change. The decline in the bee population and changes in the flowering period are having a huge impact on the harvest of bee-keepers. Since it is impossible to continuously observe the beehives in the hive with the naked eye, most people rely on knowledge based on experience about the state of the hive.Therefore, interest is focused on smart beekeeping incorporating IoT technology. In particular, with regard to swarming, which is one of the most important parts of beekeeping, we know empirically that the swarming time can be determined by the sound of the queen bee, but there is no way to systematically analyze this with data.You may think that it can be done by simply recording the sound of the queen bee and analyzing it, but it does not solve various problems such as various noise issues around the hive and the inability to continuously record.In this study, we developed a system that records queen bee sounds in a real-time cloud system and analyzes sound patterns.After receiving real-time analog sound from the hive through multiple channels and converting it to digital, a sound pattern that was continuously output in the queen bee sound frequency band was discovered. By accessing the cloud system, you can monitor sounds around the hive, temperature/humidity inside the hive, weight, and internal movement data.The system developed in this study made it possible to analyze the sound patterns of the queen bee and learn about the situation inside the hive. Through this, it will be possible to predict the swarming period of bees or provide information to control the swarming period.

Effect of Knee Joint Stimulation on the Activity of Phrenic Nerve and Inspiratory Nuron in the Cat (슬관절 자극이 횡격신경 및 흡식중추신경에 미치는 영향)

  • Cho, Dong-Ill;Han, Hee-Chul;Nahm, Sook-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.683-693
    • /
    • 1993
  • Background: During movement the major inputs to nervous system come from firstly the muscle and joint to maintain posture and motion and secondly the chemoreceptors and baroreceptors to adjust the cardiovascular and respiratory function. Their complex relationships are generally studied for many years but the direct relation between the joint and respiratory system is not studied thoroughly until now. So this experiment was performed to determine whether the natural movement of knee joint can cause the enhancement of respiratory function by observation of the changes of respiratory rate, phrenic nerve activity and inspiratory neuron activity during the stimulation of knee joint in cat anesthetized with $\alpha$-chloralose. Method: Twenty six male adult cats were used and the extracelluar recording using bipolar platinum electrode and carbon filament electrode was done to record the changes in the activities of phrenic nerve and inspiratory neuron movement of knee joint, injection of chemicals into the joint cavity and electrical stimulation of articular nerve were done. Results: The 60 Hz. could not but 120 Hz. flexion-extension movement of knee joint increased respiratory rate(R.R.), tidal neural activity(TNA) and minute neural activity(MNA). Intra-articular injection of lactate could not increase R.R. but significantly increase TNA and MNA which represented the enhanced respiratory function. Injection of potassium chloride showed similar effects with the case of lactate but the duration of effect was shorter. The electrical stimulation of medial articular nerve with IV strength which could activate only group I and II afferents showed increased TNA and MNA during stimulation but 20 V stimulation which could activate all the afferents increased all the respiratory parameters. The changes of inspiratory neuron activity by knee joint stimulation was similar to that of phrenic nerve. Conclusion: The respiratory center could be directly stimulated by the activation of group I and II articular afferents and it seemed that the magnitude of the respiratory center enhancement is proportional to the amount of sensory information from the knee joint. These facts might suggest that the respiratory function could be enhanced even by the normal movement of knee joint.

  • PDF

Analysis of Correlation between Particulate Matter in the Atmosphere and Rainwater Quality During Spring and Summer of 2020 (봄·여름철 대기 중 미세먼지와 빗물 수질 상관성 분석)

  • Park, Hyemin;Kim, Taeyong;Heo, Junyong;Yang, Minjune
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_2
    • /
    • pp.1859-1867
    • /
    • 2021
  • This study investigated seasonal characteristics of the particulate matter (PM) in the atmosphere and rainwater quality in Busan, South Korea, and evaluated the seasonal effect of PM10 concentration in the atmosphere on the rainwater quality using multivariate statistical analysis. The concentration of PM in the atmosphere and meteorological observations(daily precipitation amount and rainfall intensity) are obtained from automatic weather systems (AWS) by the Korea Meteorological Administration (KMA) from March 2020 to August 2020. Rainwater samples (n = 216, 13 rain events) were continuously collected from the beginning of the precipitation using the rainwater collecting device at Pukyong National University. The samples were analyzed for pH, EC (electrical conductivity), water-soluble cations(Na+, Mg2+, K+, Ca2+, and NH4+), and anions(Cl-, NO3-, and SO42-). The concentration of PM10 in the atmosphere was steadily measured before and after the precipitation with a custom-built PM sensor node. The measured data were analyzed using principal component analysis (PCA) and Pearson correlation analysis to identify relationships between the concentration of PM10 in the atmosphere and rainwater quality. In spring, the daily average concentration of PM10 (34.11 ㎍/m3) and PM2.5 (19.23 ㎍/m3) in the atmosphere were relatively high, while the value of daily precipitation amount and rainfall intensity were relatively low. In addition, the concentration of PM10 in the atmosphere showed a significant positive correlation with the concentration of water-soluble ions (r = 0.99) and EC (r = 0.95) and a negative correlation with the pH (r = -0.84) of rainwater samples. In summer, the daily average concentration of PM10 (27.79 ㎍/m3) and PM2.5 (17.41 ㎍/m3) in the atmosphere were relatively low, and the maximum rainfall intensity was 81.6 mm/h, recording a large amount of rain for a long time. The results indicated that there was no statistically significant correlation between the concentration of PM10 in the atmosphere and rainwater quality in summer.

Comparision of Signal-Averaged Electrocardiography (SAECG) Determined by Flank Lead System (FLS) and Pyramidal Lead System (PLS) in Healthy Young Adults (정상 성인의 직교유도체제와 피라미드유도체제에 의한 신호 가산 평균심전도의 비교)

  • Jang, Byeong-Ik;Kang, Seung-Ho;Kim, Hyeung-Il;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.179-189
    • /
    • 1993
  • It has recently become possible to record electrical activity originating from abnormally conducting myocardium from the body surface with high - gain amplification and averaging technique. These signals, which result from delayed ventricular activation(late potentials), have been recorded in patients with documented ventricular tachyarrythmia. Several electrode lead system for detecting ventricular late potential were introduced. Pyramidal electrode lead system(PLS) is useful. Also interpretation of SAECG in the young could be of value in detecting those at risk for episodic ventricular tachycardia, but suffer from a lack of data in normal young people. Selection of subjects : For this study, normal healthy young adult volunteers (age: mean 24 years) were recruited from the medical students at Yeungnam University Hospital, Internal Medicine. Twenty fourths male and seventeenths female subjects were selected. All subjects had normal resting ECGs as judged from both the standard 12 channel lead and echocardiography, and none had a history of cardiovascular disease. All subjects were considered to be in good general physical condition. Signal-averaged electrocardiography : In order to obtain low noise recordings with a small number of averaging cycles, all subject ware asked to relax completely in the supine position. Silver/silver chloride electrodes were attached after the skin was cleaned with alcohol, to constitute classic flank lead system(FLS) and pyramidal lead system(PLS). Signals were recorded and processed using a commercially available microprocessor-augmented ECG cart(Marquette Electronics, USA) suitable for portable bedside recording. There was no difference between normal values, determined by FLS and PLS at high pass filtering of 25 Hz and 80 Hz, but significant, difference was found in HFLAD and RMS-40 of 40 Hz(p<0.05). These results will provide a basis for interpretations of SAECG, determined by FLS and PLS in healthy young adults with normal QRS duration.

  • PDF

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

Application of SP Monitoring in the Pohang Geothermal Field (포항 지열 개발지역에서의 SP 장기 관측)

  • Lim Seong Keun;Lee Tae Jong;Song Yoonho;Song Sung-Ho;Yasukawa Kasumi;Cho Byong Wook;Song Young Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.164-173
    • /
    • 2004
  • To delineate geothermal water movement at the Pohang geothermal development site, Self-Potential (SP) survey and monitoring were carried out during pumping tests. Before drilling, background SP data have been gathered to figure out overall potential distribution of the site. The pumping test was performed in two separate periods: 24 hours in December 2003 and 72 hours in March 2004. SP monitoring started several days before the pumping tests with a 128-channel automatic recording system. The background SP survey showed a clear positive anomaly at the northern part of the boreholes, which may be interpreted as an up-flow Bone of the deep geothermal water due to electrokinetic potential generated by hydrothermal circulation. The first and second SP monitoring during the pumping tests performed to figure out the fluid flow in the geothermal reservoir but it was not easy to see clear variations of SP due to pumping and pumping stop. Since the area is covered by some 360 m-thick tertiary sediments with very low electrical resistivity (less than 10 ohm-m), the electrokinetic potential due to deep groundwater flow resulted in being seriously attenuated on the surface. However, when we compared the variation of SP with that of groundwater level and temperature of pumping water, we could identify some areas responsible to the pumping. Dominant SP changes are observed in the south-west part of the boreholes during both the preliminary and long-term pumping periods, where 3-D magnetotelluric survey showed low-resistivity anomaly at the depth of $600m\~1,000m$. Overall analysis suggests that there exist hydraulic connection through the southwestern part to the pumping well.

Effect of Magnesium on the Contractility of the Isolated Guinea-Pig Aortic and Rat Smooth Muscles (마그네슘이온이 적출한 기니피그 대동맥평활근과 흰쥐 자궁평활근의 수축성에 미치는 효과에 관한 연구)

  • Ahn, Hyuk;Hwang, Sang-Ik
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.452-464
    • /
    • 1990
  • It is well known that extracellular Calcium plays a very important role in several steps of smooth muscle excitability and contractility, and there have been many concerns about factors influencing the distribution of extracellular Ca++ and the Ca++ flux through the cell membrane of the smooth muscle. Based on the assumption that Mg++ may also play an important role in the excitation and contraction processes of the smooth muscle by taking part in affecting Ca++ distribution and flux, many researches are being performed about the exact role of Mg++, especially in the vascular smooth muscle. But yet the effect of Mg++ in the smooth muscle activity is not clarified, and moreover the mechanism of Mg++ action is almost completely unknown. Present study attempted to clarify the effect of Mg++ on the excitability and contractility in the multiunit and unitary smooth muscle, and the mechanism concerned in it. The preparations used were the guinea-pig aortic strip as the experimental material of the multiunit smooth muscle and the rat uterine strip as the one of the unitary smooth muscle. The tissues were isolated from the sacrificed animal and were prepared for recording the isometric contraction. The effects of Mg++ and Ca++ were examined on the electrically driven or spontaneous contraction of the preparations. And the effects of these ions were also studied on the K+ or norepinephrine contracture. All experiments were performed in tris-buffered Tyrode solution which was aerated with 100% 02 and kept at 35oC. The results obtained were as follows: 1] Mg++ suppressed the phasic contraction induced by electrical field stimulation dose-dependently in the guinea-pig aortic strip, while the high concentration of Ca++ never recovered the decreased tension. These phenomena were not changed by the a - or b - adrenergic blocker. 2]Mg++ played the suppressing effect on the low concentration [20 and 40 mM] of K+-contracture in the aortic muscle, but the effect was not shown in the case of 100mM K+-contracture. 3] Mg++ also suppressed the contracture induced by norepinephrine in the aortic preparation. And the effect of Mg++ was most prominent in the contracture by the lowest [10 mM] concentration of norepinephrine. 4] In both the spontaneous and electrically driven contractions of the uterine strip, Mg++ decreased the amplitude of peak tension, and by the high concentration of Ca++ the amplitude of tension was recovered unlike the aortic muscle. 5] The frequency of the uterine spontaneous contraction increased as the [Ca++] / [Mg++] ratio increased up to 2, but the frequency decreased above this level. 6] Mg++ decreased the tension of the low[20 and 40mM] K+-contracture in the uterine smooth muscle, but the effect did not appear in the 100mM K+-contracture. From the above results, the following conclusion could be made. 1] Mg++ seems to suppress the contractility directly by acting on the smooth muscle itself, besides through the indirect action on the nerve terminal, in both the aortic and uterine smooth muscles. 2] The fact that the depressant effect of Mg++ on the K+-contracture is in inverse proportion to an increase of K+ concentration appears resulted from the extent of the opening state of the Ca++ channel. 3] Mg++ may play a depressant role on both the potential dependent and the receptor-operated Ca++ channels. 4] The relationship between the actions of Mg++ and Ca++ seems to be competitive in uterine muscle and non-competitive in aortic strip.

  • PDF

The Effectiveness of Sympathetic Skin Response Studies for Patients with Primary Palmar Hyperhidrosis and Who Undergo Thoracic Sympathicotomy (일차성 수부 다한증에서 교감신경절제술 후 교감신경 피부반응 검사의 효용성)

  • Yoon, Jeong-Seob;Sim, Sung-Bo;Rhee, Won-Ihl
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.738-743
    • /
    • 2009
  • Background: There is no standardized tool and parameter that can accurately assess the sympathetic function before and after performing sympathectomy in patients with primary palmar hyperhidrosis. We examined the effective-ness of the sympathetic skin response (SSR) study for documenting the change of sympathetic denervation before and after performing selective thoracic sympathicotomy. Material and Method: We prospectively investigated the SSR from 12 healthy subjects who were diagnosed with primary hyperhidrosis. Each SSR was recorded on the right palm or sole with electrical stimuli applied to the skin at the left wrist and foot and vice versa for the controlateral side. This test was performed before, 2 weeks and 1 year after selective thoracic sympathicotomy. The data was corrected for the onset latency and the amplitude of the SSR (n=24). Result: The mean age of the 12 patients was $24.6{\pm}0.4$ years (range: 19~36) and the gender ratio was 1 : 0.7. The mean values of the preoperative, postoperative 2 weeks and postoperative 1 year onset latency and amplitude of the palmar side (n=24) were $1.46{\pm}0.24$ msec and $6,043{\pm}2,339{\mu}V$, $1.63{\pm}0.42$ msec and $823{\pm}638{\mu}V$, and $1.44{\pm}0.39$ msec and $2,412{\pm}1,546{\mu}V$, respectively. The mean values of the plantar side (n=38) were $1.83{\pm}0.42$ msec and $2,816{\pm}1,694{\mu}V$, $2.16{\pm}0.39$ msec and $1,445{\pm}1,281{\mu}V$ and $1.95{\pm}0.25$ msec and $1,622{\pm}865{\mu}V$, respectively. Among the documented parameters, only the palmar amplitude (p=0.002) showed statistical significance in recording the change of the sympathetic system within the same individual for the pre and postoperative period. Conclusion: The SSR amplitude ratio may be a useful parameter for documenting the efficacy of sympathetic denervation after selective sympathicotomy.