• Title/Summary/Keyword: Electrical power monitoring system

Search Result 724, Processing Time 0.034 seconds

Development of Non-contact Detector for Broken Cords of Steel-Cord Conveyor Belt (컨베이어벨트의 비접촉식 스틸코드파선 검사장치 개발)

  • Yoo, Jae-Sang;Son, Boong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2535-2537
    • /
    • 2000
  • In order to detect and monitor the broken cords of steel-cord belt from being damaged by impact of large lump of materials and the corrosion of steel cord, we developed a non-contact magnetic coil detection system. This measures the deterioration of reinforcing cables in steel cord conveyor belt which transport the ores in raw material plant. In this research, magnetic coil sensor of broken-cord detection system has exciting part and sensing part. The broken-cord detection system is operated by supplying a transmitter coil with electric power to generate magnetic field, and then the change of induced voltage is detected in each receiver coils due to resultant magnetic flux effected by the broken steel cords at the inside of the conveyor belt. By the informations such as the position and size of the broken steel cords obtained by SCBMS(Steel Cord Belt Monitoring System), it is expected that not only the span of belt life will be lengthened, but also this system can enable operators to plan scheduled maintenance and prevent the enlargement of damaged parts in steel cord belt at an early stage

  • PDF

Cost Analysis of Electrokinetic Process for Desalination of Saline Agricultural Land (염류집적 농경지 탈염을 위한 전기역학적 처리공정의 비용산출)

  • Kim, Do-Hyung;Choi, Jeong-Hee;Jo, Sung-Ung;Baek, Ki-Tae
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.91-97
    • /
    • 2012
  • In this study, cost analysis of electrokinetic (EK) restoration process for desalination of saline agricultural land was performed for field application based on a pilot scale field application. For reasonable cost analysis, EK process was classified into three major parts: system design, installation and operation. Cost of system installation consists of materials and installation for electrode/electric wire, power supply and data monitoring, drainage system, etc. Operation cost was calculated based on electrical consumption and water charges for EK process. Total cost for EK process was 2,943,013 won for $1000m^2$ in greenhouse area. Cost for system installation was 2,553,786 won, that is, 87% of total cost, while cost for system operation was 389,229 won, that is, 13% of total cost.

An 2.4 GHz Bio-Radar System for Non-Contact Measurement of Heart and Respiration (호흡 및 심박수 측정을 위한 비 접촉 방식의 2.4 GHz 바이오 레이더 시스템)

  • Lee, Yong-Jin;Jang, Byung-Jun;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.191-199
    • /
    • 2008
  • In this paper, we present a performance analysis and design and implementation results of a 2.4 GHz bio-radar system that can detect human heartbeat and respiration signals. In order to design a 2.4 GHz bio-radar system qualitatively, we investigate the electromagnetic properties of human tissues and calculate the target SNR of demodulation output with respect to distance. The target SNR is defined by the 90 % success ratio for detecting heartbeat signal. With this target SNR value, the performance and link budget of the bio-radar system is simulated using MATLAB. Using this link budget results, the direct conversion receiver is designed and Implemented in 4 layer printed circuit board(PCB). With output power of 0 dBm and 5 Hz bandwidth, 80 % success ratio of 50 cm is measured. Measurement results show a good agreement with simulation results.

Interference Suppression Based on Switching Beamforming for TPMS (스위칭 빔형성기 기반의 TPMS 용 간섭제거 기술)

  • Park, Cheol;Kim, Seong-Min;Hwang, Suk-Seung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.4
    • /
    • pp.436-441
    • /
    • 2011
  • A TPMS is a wireless communication system designed to monitor its condition inside the pneumatic tires on various types of vehicles. These systems report the tire pressure information to the driver of the vehicle. While wireless communications is used to transmit the measurement data from TPMS sensors to a central processing unit in the vehicle, it suffers from the various interferences such as sensors of each tire or outside electrical equipments. Based on the conventional beamformer, a switching beamforming technique is proposed to minimize the interference and efficiently receive valid data. Moreover, in order to minimize the interference and reduce power consumption for communication, a system with unique Gold Code is presented for each tire. The performance of interference suppression is illustrated by computer simulations.

Noise Analysis and Measurement for a CW Bio-Radar System for Non-Contact Measurement of Heart and Respiration Rate (호흡 및 심박수 측정을 위한 비접촉 방식의 CW 바이오 레이더 시스템의 잡음 분석 및 측정)

  • Jang, Byung-Jun;Yook, Jong-Gwan;Na, Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1010-1019
    • /
    • 2008
  • In this paper, we present a noise analysis and measurement results of a bio-radar system that can detect human heartbeat and respiration signals. The noise analysis including various phase noise effects is very important in designing the bio-radar system, since the frequency difference between the received signal and local oscillator is very small and the received power is very low. All of the noise components in a bio-radar system are considered from the point of view of SNR. From this analysis, it can be concluded that the phase noise due to antenna leakage is a dominant factor and is a function of range correlation. Therefore, the phase noise component with range correlation effect, which is the most important noise contribution, is measured using the measurement setup and compared with the calculated results. From the measurement results, our measurement setup can measure a closed-in phase noise of a free-running oscillator. Based on these results, it is possible to design a 2.4 GHz bio-radar system quantitatively which has a detection range of 50 cm and low power of 1 mW without additional PLL circuits.

Design of Simulated Photovoltaic Power Streetlight for Education using Renewable Energy Utilization and Storage Function (신재생에너지 활용 및 저장기능을 이용한 교육용 모의 태양광발전 가로등 설계)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.2
    • /
    • pp.137-142
    • /
    • 2021
  • A Photovoltaic power streetlight is a system that uses solar energy to charge a secondary battery and then uses it for night lighting through a lamp, and can be configured as a standalone or grid-connected type by installing an LED streetlight at the load end. The energy generated through the solar cell module can be charged to the secondary battery through the charge/discharge control device, and then the LED street light can be turned on and off by comparing the power generation voltage and the charging voltage according to the monitoring of solar radiation, or by setting a specific time after sunset or sunrise. Based on these contents, this paper designed and manufactured a simulated solar power streetlight for education using new and renewable energy utilization and storage functions. Using these educational equipment, students can 1) understand the flow of energy change using renewable energy including sunlight as electric energy, 2) understand new and renewable energy, and cultivate basic design and manufacturing application power of related products, 3) The use of new and renewable energy through power conversion and strengthening of practical training and analysis through hardware production can be instilled.

The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital buildings (대형병원에서 마이크로터빈 이용한 열병합시스템 에너지성능 및 경제성 분석)

  • Kim, Byung-Soo;Gil, Young-Wok;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.176-183
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat, and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30[%] after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40[%]. If electricity energy and waste heat in turbine are used, 56[%] of heating energy and 67[%] of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70[%].

Monitoring of the Jamming Environment in the GNSS L5 Band in Korea Region

  • Lee, Hak-beom;Song, Young-Jin;Park, Dong-Hyuk;Lee, Sanguk;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.4
    • /
    • pp.353-361
    • /
    • 2021
  • This paper presents the jamming effect on the L5 band of Global Navigation Satellite System (GNSS) by analyzing real data collected via measurement campaigns in Korea region. In fact, the L5 band is one of the dedicated bands for various satellite navigation systems such as Global Positioning System (GPS), Galileo, BeiDou (BDS), and Quasi Zenith Satellite System (QZSS). And this band is also allocated along with various systems used for aeronautical radio navigation systems (ARNS). Among ARNS, the Distance Measuring Equipment (DME) and the Tactical Air Navigation System (TACAN) are systems that transmit and receive strong power pulse signals, which may cause unintentional jamming in the reception of GNSS signals. In this paper, signals in the main lobe of GPS L5, Galileo E5a, BDS B2a, and QZSS L5 are collected in Korean region to confirm whether the jamming effect exists in the band. And then, the pulse blanking technique, which is a simple signal processing technique capable of responding to pulsed jamming, is applied to analyze the jamming effect of DME/TACAN on the L5 band.

A power loss monitoring system using AMI (지능형 원격검침을 이용한 전력감시.손실 시스템)

  • Myoung, No-Gil;Kim, Young-Hyun;Lee, Sang-Youm
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1828-1829
    • /
    • 2011
  • 본 논문에서는 KEPCO가 사업화중인 AMI(Advanced Metering Infrastructure)시스템을 이용하여 변압기 2차 측에서의 전력공급량 측정과 수용가로부터의 전력사용량 수집하고, 상기 전력사용량의 차이를 비교 분석하여 통상적인 전력 손실 및 도전감시를 수행할 수 있는 방법을 소개하고자 한다. 전력 감시모듈은 전원 공급부, 전류 및 전압 감지부, 수집한 전류 및 전압을 이용하여 각종 정보를 생성하는 엔진부 및 데이터 통신부로 구성된다. 전력손실 및 도전감시 방법은 전자식 전력량계가 생성하는 LP(Load Profile)의 15분 기록주기를 기준으로 전력공급량과 전력 사용량을 비교 분석하여 통상적인 전력 손실률을 산출한다.

  • PDF

A Study on Smart-Plug for Electric Power Monitoring System Based on AMI (AMI 기반 전력 모니터링을 위한 스마트 플러그 연구)

  • Bae, Sun-Ho;Kang, Byung-Kwan;Kim, Seung-Tak;Lee, Hyun-Koo;Park, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.612-613
    • /
    • 2011
  • AMI (Advanced Metering Infrastructure)는 스마트 그리드에서 핵심 시스템이며, 기술 자체가 어렵지 않기 때문에 실현 가능성이 가장 높은 분야라고 할 수 있다. 소비자와 공급자 사이에서 단순한 전기 소비 측정에 그치는 것이 아니라 측정한 정보의 저장과 교환이 실시간으로 이루어지는 스마트 그리드 환경에서 원격으로 실시간 전력 계측기인 스마트 미터의 필요성이 증대되고 있다. 이에 따라 본 논문에서는 스마트 미터를 기존 플러그의 디자인으로 제작하여 어느 기기에도 적용이 가능한 형태인 스마트 플러그의 연구와 성능을 검토한다.

  • PDF