• 제목/요약/키워드: Electrical power monitoring system

검색결과 723건 처리시간 0.024초

전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발 (Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication)

  • 김상동;박지호;김동완
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

Development of a Multiple SMPS System Controlling Variable Load Based on Wireless Network

  • Ko, Junho;Park, Chul-Won;Kim, Yoon Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1221-1226
    • /
    • 2015
  • This paper proposes a multiple switch mode power supply (SMPS) system based on the wireless network which controls variable load. The system enables power supply of up to 600W using 200W SMPS as a unit module and provides a controlling function of output power based on variable load and a monitoring function based on wireless network. The controlling function for output power measures the variation of output power and facilitates efficient power supply by controlling output power based on the measured variation value. The monitoring function guarantees a stable power supply by observing the multiple SMPS system in real time via wireless network. The performance of the proposed system was examined by various experiments. In addition, it was verified through standardized test of Korea Testing Certification. The results were given and discussed.

공장 전기 설치를 위한 휴대용 전력품질 모니터링 시스템 (Hand-Held Power Quality Monitoring System for Factory Electrical Installation)

  • 최상열
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.113-118
    • /
    • 2015
  • 본 연구에서는 휴대용 계측기기를 이용한 공장 수용가 전력품질 분석시스템을 제시한다. 기존의 전력품질 분석시스템은 주로 대규모 공장 수용가에서 상시 연결 되어, 공장 전력 데이터를 연속적으로 취득, 저장한 후 분석까지 수행하고 있다. 그러나 이러한 시스템의 문제점은 데이터 취득을 위해 설치된 미터에서 수집된 Raw 데이터를 이용하여 공장 수용가의 전체적인 전력 품질을 감시 할 수는 있으나, 비선형 부하의 조합으로 인한 전력품질 저하 발생 시에는 그러한 상황에 대한 구체적인 원인을 파악하는 것은 불가능하다. 따라서 본 연구에서는 공장의 전력품질 저하가 발생되는 경우 의심되는 여러 부하의 전압, 전류를 직접 측정하여 그 원인이 되는 지점을 쉽게 찾아내고 그에 상응하는 조치가 가능하도록, 휴대용 계측기기 기반 공장 수용가 전력품질 분석시스템을 제시함으로써 보다 안정적인 공장 전력 부하 운영이 가능하도록 한다.

발전기 탈락에 따른 주파수의 전파속도 해석에 관한 연구 (A Study on Analysis of Propagation Speed of Power Frequency by Generation Drop)

  • 김학만;박철원
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.295-300
    • /
    • 2014
  • The frequency is an important operating parameter of a power system. There is an increasing importance of constant monitoring of frequency to achieve stable power supply by WAMS(wide area monitoring system) and FNET(Frequency Monitoring Network). This paper is part of development of a network-based frequency monitoring and failure prediction system for wide-area intelligent protection relaying. In this paper, analysis of propagation speed of power frequency by generation drop using the PSS/E was carried out. For dynamic analysis, the 11 metropolitan areas offices of KEPCO divided into five groups of Seoul, Gangwon, Chungcheong, Honam, and Yeongnam group, study was performed.

차단기 트립코일 이상감지 장치 (A Trip Coil Fault Detection of Circuit Breaker)

  • 윤주혁;이종헌;박노식;이동희
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.61-68
    • /
    • 2011
  • The circuit breaker of power distribution board is essential part for the protection of electrical disaster from load short, trouble of power system. For the normal operation of circuit breaker, trip coil of the circuit breaker can cut the mechanical contact of circuit breaker from the detection of power system troubles. This paper presents a design and experimental results of trip coil fault detection system for the real time monitoring of the circuit breaker. The designed system is consisted by the trip coil fault detector which is connected to the each circuit breaker and remote monitoring unit. The trip coil fault detector can detect the impedance and operating voltage of the trip coil, and the detected values are compared with the normal state. And the remote monitoring unit can be connected to the 32 channels of trip coil fault detectors by serial communication. From the designed system, the fault and normal states of the trip coil can be remotely monitored in real time. The designed system is verified by the practical circuit breaker of power distribution board. And the results shows the effectiveness of the designed system.

CAN을 이용한 발전계통의 제어 및 모니터링 기법 연구 (A Study on the Power System Control and Monitoring Technique Using CAN)

  • 정준홍;최수영;박기헌
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.268-276
    • /
    • 2003
  • In this paper, we present a new control and monitoring technique for a power system using CAN(Controller Area Network). Feedback control systems having co'ntrol loops closed through a network(i.e. Ethernet, ControlNet, CAN) are called NCSs(Networked Control Systems). The major problem of NCSs is the variation of stability property according to time delay including network-induced delay and computation delay in nodes. We present a new stability analysis method of NCSs with time delay exploiting a state-space model of LTI(Linear Time Invariant) interconnected systems. The proposed method can determine a proper sampling period of NCSs that preserves stability performance even in NCSs with a dynamic controller. We design CAN nodes which can transmit control and monitoring data through CAN bus and apply these to NCSs for a power system. The results of the experiment validate effectiveness of our control and monitoring technique for a power system.

익일 빌딩 부하 예측 기능을 갖는 빌딩에너지관리시스템 (Building Energy Management System with Next Day Demand Forecasting of Building Load)

  • 최상열
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.119-123
    • /
    • 2014
  • 본 연구에서는 익일부하예측 기능을 갖는 빌딩에너지관리시스템을 제시한다. 기존의 빌딩에너지 관리시스템은 빌딩내의 다양한 인프라를 이용하여 에너지를 감시 한다 그러나 이러한 시스템을 구현하기 위해서는 많은 인프라 구축비용이 소요 되어, 에너지 절감을 위한 인프라 구축비용과 실제 절감된 전기 요금을 비교 할 경우, 에너지 절감을 위해 투자한 비용을 전기 요금 절약으로 회수하는데 수년이 걸리고, 또한 인프라 설비 유지 보수를 고려할 경우, 결과적으로 에너지 절약 효과가 미비하다. 따라서 본 연구에서는 보다 저렴하고 합리적인 방법으로 빌딩의 에너지 소비를 억제할 수 있도록, 기상청데이터와 한전의 ISmart 데이터를 기반으로 데이터마이닝기법을 이용하여 빌딩의 익일 부하 사용량을 예측하고 이를 기반으로 빌딩 부하의 On/Off를 수행하도록 빌딩에너지관리시스템을 구현함으로써 상대적으로 저렴한 비용으로 빌딩에너지 사용의 합리화를 이루도록 하였다.

중대규모 계통연계형 PV시스템의 성능결과 (Performance monitoring results of large-scale PV system)

  • 소정훈;유권종;정영석;유병규;황혜미;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1165-1166
    • /
    • 2006
  • This paper presents performance monitoring results of large scale photovoltaic (PV) system supported by general dissemination & regional energy program in korea government polices for new and renewable energy resources. 80kW PV system and monitoring system is constructed and monitored PV system performance to observe the overall effect of environmental conditions on their operation characteristics. The PV system performance has been evaluated and analyzed for component perspective (PV array and power conditioning unit) and global perspective (system efficiency, capacity factor, and electrical power energy and power quality etc.) for six month monitoring periods.

  • PDF

풍력발전 시스템의 계통연계에 따른 전력품질 모니터링 및 진단 (Power Quality Monitoring and Diagnosis for the Distribution System Interconn of Wind Turbine)

  • 장석명;이성호;윤인기;조한욱;윤기갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.251-253
    • /
    • 2002
  • Various measures of power quality are addressed, specifically power factor, power variability, electrical transients, flicker and harmonics. This paper presents the measurement criteria for monitoring and diagnosis of power quality according to the distribution system interconnection of wind turbine.

  • PDF