• Title/Summary/Keyword: Electrical power monitoring system

Search Result 723, Processing Time 0.031 seconds

Practical Applications of Multi-Agent Transformer Condition Monitoring (다수 변압기의 온라인 모니터링을 위한 실제 적용)

  • Yun, Ju-Ho;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.96-99
    • /
    • 2008
  • On-line condition monitoring is a useful tool for maintaining and extending the longevity of power transformers. An intelligent diagnostic system is desirable for operational safety and reliability. Bringing these concepts together results in a powerful support tool for engineers, reducing the volume of data to deal with, and making the data more meaningful. This paper describes how a multi-agent system for diagnosing the cause of transformer partial discharge activity was coupled with a method of UHF partial discharge monitoring, creating an on-line condition monitoring system. The challenges presented by the on-site environment are discussed, along with the implications for the complete system.

  • PDF

A study on the Monitoring System for Apartment Power Apparatus (공동주택에서 전력설비 감시에 관한 연구)

  • 김정태;이기홍;홍규장;유건수
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.68-78
    • /
    • 1995
  • Until now, the electrical monitoring system had been used of the Graphic-Mosaic panel, which is located to the cellar at the apartment complex. it was inappropriated to man-power and system-organization at apartment complex. for that reason, in this paper IMS is presented. An Intelligent Monitoring System can provide and explanation of real-time opera- state of an electric power apparatus to its operators in apartment complex. IMS is proposed as a model for integration supervisory system whose primary tasks are to communicate line data with host-computer and slave-controller it is based on a generalized version of use-career and a trouble shoot knowledge base for diagnostic problem solving. to operate it, both of controller and its operator-view is deigned by the real-tune O.S TREND 940.

  • PDF

A study Improvement Direction for Arc Interruption Equipment and On-line Monitoring System of Consumer Low Voltage Facilities (수용가 저압 전기설비의 원격 감시시스템 및 아크차단 장치 활성화 방안에 관한 연구)

  • Kim, Gi-Hyun;Park, Chee-Hyun;Lim, Young-Bai;Choi, Myeong-Il;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.79-86
    • /
    • 2008
  • Domestic and foreign follows the trend which is that safety checkup of electrical facilities is serviced by on-line system with joining information technology. This paper research improvement of what kind of system and law for market environment of electric power value added service. For improvement of market environment of electric power value added service, this paper researches improvement of on-line monitoring system and necessity of arc interruption and revision of arc related law.

Development of Monitoring System for Interconnection of Distributed Generation with Power Grid (분산전원 계통 연계를 위한 모니터링 시스템의 개발)

  • Oh, Sung-Nam;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.714-716
    • /
    • 2004
  • Owing to the environmental problems as well as increasing energy prices and power plant construction costs, many researches have been made for the safe operation of distributed generations. In order to be more popularly used in parallel with the distribution network, the distributed generation and its correlation with the power system should be exactly monitored at any time. This paper presents a monitoring system which displays the important states of the distributed generation in operation and stores various measurements of the system. The proposed system constructs a data-base for developing algorithms against any faults of the interconnected system, and monitors efficiently at any place with the communication network function.

  • PDF

An Improved Interval AHP Method for Assessment of Cloud Platform-based Electrical Safety Monitoring System

  • Wang, Shou-Xiang;Ge, Lei-Jiao;Cai, Sheng-Xia;Zhang, Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.959-968
    • /
    • 2017
  • Electrical safety monitoring System (ESMS) is a critical component in modern power systems, which is characterized by large-scale access points, massive users and versatile requirements. For convenience of the information integration and analysis, the software development, maintenance, and application in the system, the cloud platform based ESMS is established and assessed in this paper. Firstly the framework of the system is proposed, and then the assessment scheme with a set of evaluation indices are presented, by which the appropriate cloud product can be chosen to meet the requirements of a specific application. Moreover, to calculate the weights of the evaluation indices under uncertainty, an improved interval AHP method is adopted to take into consideration of the fuzziness of expert scoring, the qualitative consistency test, and the two normalizations in the process of eigenvectors. Case studies have been made to verify the feasibility of the assessment approach for ESMS.

Development of Single Phase Cabinet Panel with Electrical Safety Monitoring System by Mobile (모바일 이용 가능형 ESMS 기능의 단상 분전반 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.92-96
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the ESMS(electrical safety monitoring system) which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment are able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the ESMS and obtained certification. And we tested the over current, leakage current and arc under the normal condition.

BILBO Network: a proposal for communications in aircraft Structural Health Monitoring sensor networks

  • Monje, Pedro M.;Aranguren, Gerardo
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.3
    • /
    • pp.293-308
    • /
    • 2014
  • In the aeronautical environment, numerous regulatory and communication protocols exist that cover interconnection of on-board equipment inside the aircraft. Developed and implemented by the airlines since the 1960s, these communication systems are reliable, strong, certified and able to contact different sensors distributed throughout the aircraft. However, the scenario is slightly different in the structural health monitoring (SHM) field as the requirements and specifications that a global SHM communication system must fulfill are distinct. The number of SHM sensors installed in the aircraft rises into the thousands, and it is impossible to maintain all of the SHM sensors in operation simultaneously because the overall power consumption would be of thousands of Watts. This design of a new communication system must consider aspects as management of the electrical power supply, topology of the network for thousands of nodes, sampling frequency for SHM analysis, data rates, selected real-time considerations, and total cable weight. The goal of the research presented in this paper is to describe and present a possible integration scheme for the large number of SHM sensors installed on-board an aircraft with low power consumption. This paper presents a new communications system for SHM sensors known as the Bi-Instruction Link Bi-Operator (BILBO).

Development of a Remote Central Monitoring System of Street Lights (가로등 원격감시 중앙관제시스템 개발)

  • Ha, Kwan-Yong;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.43-45
    • /
    • 2004
  • A remote monitoring system was developed to improve inconveniences of manual work such as monitoring street lights by using current sensors, microprocessor and RF communication system. In order to control the street lights on the roads effectively and monitor them in real time, we can attach current sensor to the street lights which monitors Lamp, the broken part and state of the Balast, and the amount of an electric leak precisely we developed a system which makes it possible to transmit the data on monitoring results in breakdown of street lights and Balasts to the central monitoring computer without setting up extra data transmission line. The system we devised can transmit data through Power Line Modem and RF communication using relay method to the central controlling computer without any loss of data.

  • PDF

On-Line Condition Monitoring and Diagnostics of Distribution Equipment (배전반 설비의 온라인 모니터링 및 진단)

  • Yun, Ju-Ho;Im, Wan-Su;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.525-526
    • /
    • 2007
  • Continuous on-line temperature monitoring provides the means to evaluate current condition of equipment and detect abnormality. It allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Study Tendency of Cyber Security in Power IT Area (전력 IT Cyber Security 연구 동향)

  • Kim, Hak-Man;Park, Jae-Sae;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.205-206
    • /
    • 2008
  • Electrical Power System is very important infrastructure in the country. The functions of control, monitoring and so on in the electrical power system are implemented by information technologies(IT) through cyber space. Recently, many activities for enhancing cyber security in the world. In this paper, we introduce the study tendency of cyber security in power IT areas.

  • PDF