• Title/Summary/Keyword: Electrical potential

Search Result 2,954, Processing Time 0.031 seconds

Effects of Position of Auxiliary Probe on Ground Resistance Measurement Using Fall-of-Potential Method

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance using the fall-of-potential method are described and the testing techniques for minimizing the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error in the measured value of the ground resistance due to the position of the potential probe, the ground resistance was measured for the case in which the distance of the current probe was fixed at 50[m] and the distance of the potential probe was located from 10[m] to 50[m]. Also, the potential probe was located in turn at $30[^{\circ}]$, $45[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$, and $180[^{\circ}]$. As a consequence, relative error decreased with increasing distance of the potential probe and decreasing angle between the current probe and potential probe. The results could help to determine the position of the potential probe during the ground resistance measurement.

Distribution of Potential Rise as a Function of Shape of Grounding Electrodes

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.73-79
    • /
    • 2007
  • In order to analyze the potential rise of grounding systems installed in buildings, a hemispherical grounding simulation system was studied. Potential rise was measured and analyzed regarding the shape and distance of the grounding electrodes by using this system. The system was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured in real time by the horizontal moving probe of be potentiometer. The test grounding electrodes were fabricated through reducing the grounding electrode installed in real buildings such as the ground rod, grounding grid and so on. The potential rise was displayed in a two-dimensional profile and was analyzed regarding the shapes of the ground electrodes. The potential rise of the grounding grid combined with a ground rod was the lowest of every grounding electrode tested. The proposed results can be applicable to evaluating ground potential rise in grounding systems, and the analytical data can be used to stabilize the electrical installations and prevent electrical disasters.

A Simulator for Potential Distribution Analysis

  • Kil, Gyung-Suk;Gil, Hyong-Jun;Park, Dae-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.225-229
    • /
    • 2012
  • This paper proposes a reduced-scale simulator that can replace numerical analytic methods for the estimation of potential distribution caused by ground faults in various grounding systems. The simulator consists of a hemispherical electrolytic tank, a three-dimensional potential probe, a grounding electrode, and a data acquisition module. The potential distribution is measured using a potentiometer with a position-tracing function when a test current flows to the grounding electrode. Using the simulator, we could clearly analyze the potential distribution for a reduced- scale model by one-eightieth of the buried depth and length of the grounding rod and grounding grid. Once both the shape of the grounding electrode and the fault current are known, the actual potential distribution can be estimated.

Analysis of Meridians Potential as Ground Condition for Objectification of Acupuncture Effect (침술 효과의 객관화를 위한 접지조건에 따른 경락전위분석)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.436-441
    • /
    • 2007
  • Background: As patients are positioned at insulated bed and practitioner are positioned at insulated floor or shoes, it could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. Method: We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground, respectively. Result: All ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. practitioner ground only showed negative mean potential $-51.5{\pm}9.3{\mu}V\;and\;367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential as $2.9{\pm}1.3{\mu}V,\;16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential as $1.6{\pm}0.7{\mu}V,\;3.3{\pm}1.9{\mu}V$ of peak to peak potential. respectively.

Influence on Meridians Electric Potential for Electrical Ground and Insulation (-침술효과 객관화를 위한 연구- 접지와 절연조건이 경락전위에 미치는 영향)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2243-2250
    • /
    • 2006
  • When a patient is positioned at insulated bed and practitioner is positioned at insulated floor, that condition could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection and Insulation could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated non-insulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground respectively. Then we used insulated needles and measured same as above. Non-insulated all ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. Practitioner ground only showed negative mean potential of $51.5{\pm}9.3{\mu}V$ and $367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential of $2.9{\pm}1.3{\mu}V$, $16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential of $1.6{\pm}0.7{\mu}V$, $3.3{\pm}1.9{\mu}V$ of peak to peak potential. In case of Insulated condition, there elicited no mean potential. Non ground and Practitioner only showed weak value of peak to peak potential as $7.8{\pm}2.6{\mu}V$ and $8.4{\pm}2.5{\mu}V$ each. But patient only and all ground showed no potential as $4.7{\pm}2.2{\mu}V$, $3.4{\pm}2.2{\mu}V$, respectively. Therefore, Ground connection modulate the energy transfer course between practitioner and patient. Insulation block energy transfer but static electrical impulse between practitioner and patient.

The Effect of Drinking Alcohol on Bio-electrical Potential at Twelve Source Points : A Cross-over Study (음주(飮酒)가 십이원혈(十二原穴)의 체표전위에 미치는 영향 : 교차대조연구)

  • Kim, Jung-Wan;Kim, Jae-Hong;Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.39 no.1
    • /
    • pp.44-54
    • /
    • 2018
  • Objectives: The objective of this study is to investigate the effects of drinking alcohol on bio-electrical potential at twelve source points. Methods: Twenty healthy adults were assigned to alcohol and water groups by a random cross-over design. Bio-electrical potential at twelve source points were measured before and after drinking alcohol or water and the change of bio-electrical potential was analyzed and compared between the alcohol and the water groups. Results: Bio-electrical potential at LI4, ST42, KI3, PC7, TE4, GB40, LR3 in the alcohol group was significantly increased compared to those in the water group. Conclusions: Drinking alcohol increased bio-electrical potential at source points of LI, ST, KI, PC, TE, GB and LR in healthy human subjects.

Grounding Characteristic Analysis of Plate Electrodes

  • Kim, Sung-Sam;Kim, Ju-Chan;Koh, Hee-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.53-60
    • /
    • 2007
  • In this study, an experiment on the efficient construction method of plate electrodes, the influence of electric potential interference in plate electrodes, and building foundations were explored. The experimental result of the electric potential measurement was taken on the basis of the direction of movement and the condition in which the plate electrodes are laid underground in building foundations. It shows that the construction method of laying the plate electrodes vertically exhibits a more efficient reduction of electric potential in a diagonal direction and on an X axis than laying plates horizontally. For plate electrode construction in an area that has uniform conditions, the parallel joint construction method is more effective than a single construction to reduce earth electrical potential and ground resistance. In addition, a straight arrangement performs well in ground efficiency, compared to the parallel arrangement.

Comparison of Individual and Common Grounding Method for Potential Rise (전위상승에 대한 독립접지방식과 공통접지방식의 비교)

  • Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yeon;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.41-43
    • /
    • 2006
  • This paper deals with a comparison of individual and common grounding method for potential rise. When a test current flowed through grounding electrode, potential rise was measured and analyzed for grounding method using a electrolytic tank in real time. The grounding electrodes were designed and fabricated with ground rods on a scale of one-eightieth. Potential rises of individual grounding method were higher than those of common grounding method. The distributions of surface potential are dependent on the distance from grounding electrode.

  • PDF

Research on Assessment of Potential Interference between Individual Grounding Electrodes Using an Electrolytic Tank Modeling Method

  • Gil, Hyoung-Jun;Kim, Dong-Ook;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.27-33
    • /
    • 2008
  • This paper deals with the assessment of potential interference between individual grounding electrodes using an Electrolytic Tank Modeling method. When a test current was passed through a grounding electrode, potential rise was measured and analyzed using an electrolytic tank in real time. In order to analyze the potential interference between grounding electrodes, a reduced scale modeling method was studied. Potential interference between isolated grounding electrodes was evaluated as a function of the separation distance between grounding electrodes and the configuration of grounding electrode to be induced. It was found that the separation distance between grounding electrodes was a major factor in reducing the potential interference.

Path Planning of Mobile Robot using Weighted Potential Function with Obstacle Avoidance (가중화된 포텐셜 함수를 이용한 이동 로봇의 장애물 회피 경로 계획)

  • Kim, Jin-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.15-19
    • /
    • 2009
  • This paper presents the potential field for mobile robot path planning. The proposed repulsive potential has weighted parts, which consists of conventional repulsive potential and goals nonreachable with obstacles nearby repulsive potential. It ensures the global minimum of the total potential when the robot approaches goals near obstacle and the robot passes the adjacent obstacles. Simulation results shows that the proposed potential is better than conventional potentials.