• 제목/요약/키워드: Electrical impedance analysis

검색결과 657건 처리시간 0.027초

Grid-friendly Characteristics Analysis and Implementation of a Single-phase Voltage-controlled Inverter

  • Zhang, Shuaitao;Zhao, Jinbin;Chen, Yang;He, Chaojie
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1278-1287
    • /
    • 2017
  • Inverters are widely used in distributed power generation and other applications. However, their lack of inertia and variable impedance may cause system instability and power transfer inaccuracy. This paper proposes a control scheme for a single phase voltage-controlled inverter with some grid-friendly characteristics. The proposed control algorithm enables the inverter to function as a voltage source with an inner output impedance in both the islanded and grid-connected modes. Virtual inertia and rotor equations are embedded in the PLL part. Thus, the frequency stability can remain. The inner output impedance can be adjusted freely, which helps to accurately decouple and transmit the output active and reactive power. The proposed inverter operates like a traditional synchronous generator. Simulations and experiments are designed and carried out to verify the proposed control strategy.

An Improved Control Method for Power Conversion System under a Weak Grid by the Adoption of Virtual Resistors

  • Gao, Ning;Sang, Shun;Li, Rui;Cai, Xu
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.756-765
    • /
    • 2017
  • The control of the power conversion system (PCS) in a battery energy storage system has a challenge due to the existence of grid impedance. This paper studies an impedance model of an LCL-based PCS in the d-q domain. The feature of a PCS connected to a weak grid is unveiled by use of an impedance model and a generalized Nyquist criterion. It is shown that the interaction between grid impedance and the PCS destabilizes the cascaded system in certain cases. Therefore, this paper proposes a novel control method that adopts virtual resistors to overcome this issue. The improvement in the control loop leads the PCS to a more stable condition than the conventional method. Impedance measurement is implemented to verify the correctness of the theoretical analysis. Experimental results obtained from a down-scaled prototype indicate that the proposed control method can improve the performance of the PCS under a weak grid.

가정용 연료전지 스택의 EIS 평가 기법 개발 (Development of EIS Evaluation Method about PEMFC 1kW STACK)

  • 박찬엄;한운기;정진수;고원식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.100.1-100.1
    • /
    • 2011
  • Electrochemical impedance spectroscopy(EIS) are using widely as a useful technique mainly in the field of electrochemical for the analysis of electrode reactions or characteristics of the composites. The response analysis of the systems technique provides comprehensive informations about the characteristic and structure of complex and internal reaction. The EIS is the method to measure impedance of the measurement target classified by the frequency, it select the equivalent impedance model to give same response from the result and it calculate the parameter. Therefore, the chemical reaction inside the fuel cell is to modeling to electrical impedance. And as repeating the same experiment in each of the operating point, we can get each different parameter. As a result, we can establish the equivalent impedance model in each operating point. Therefore, if we use these models, we can evaluate the fuel cell without the internal design parameter of the fuel cell as required in existing modeling. The EIS is used typically technique for distinguish status of fuel cell called SOH(State Of Health). When the fuel cell is degradation, Efficiency and health of the fuel cell is reduced because internal impedance is increase. As usage of these principles, we can evaluate state of fuel cell through the impedance analysis of fuel cells. In this study, we are presents EIS distinction system and algorithm for residential fuel cell systems. At the time of the fuel cell installation in the fields, the EIS system and proposed algorithm will be able to apply as technique for efficiency and performance evaluation about fuel cell system.

  • PDF

임피던스 위상각제어를 적용한 초음파모터의 구동을 위한 새로운 제어방식에 대한 연구 (A Study on the Novel Control Method to Drive the Traveling Wave Type Ultrasonic Motor adapting the Impedance Angle Control)

  • 이을재;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권6호
    • /
    • pp.450-456
    • /
    • 2000
  • In this paper, we proposed a novel control method which uses the internal impedance angles as a control parameter to drive traveling wave type ultrasonic motor. An impedance characteristic of the ultrasonic motor is obtained by analysis of the equivalent circuits including the external inductor used to generate the coupled resonance. The phase angle of internal impedance to achieve optimal control performance is derived. For the tracking of impedance angle, an information of phase difference is obtained from the applied voltage and current. The high speed phase difference detector is designed to monitor the phases of ultrasonic motor. The effectiveness of the proposed control scheme is clarified by experiments.

  • PDF

양손 임피던스법에 의한 SV 측정의 정확도 향상을 위한 연구 (A Study on Improvement of the Accuracy of SV Measurement obtained by Hand to Hand Impedance.)

  • 윤찬솔;염호준
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1251-1255
    • /
    • 2015
  • The purpose of this study is to measurement the cardiac output using hand to hand impedance method to provide convenience to user when measuring SV(stroke volume) with the use of ICG(Impedance Cardiography). We suggest the optimized modified formula, which can be applied when using impedance with the use of hand to hand Impedance. To verify this formula, a SV from transthoracic approach and hand to hand approach are compared for the 36 subjects, respectively. The acquired data was analyzed by using LabVIEW 8.6, analysis was implemented by SPSS 12.0. Fine difference was shown by individual. We showed that as a result of analyzing the ICG measurement value on thoracic and hand to hand, the correlation with SV was r=0.716, thereby having indicated the results of regression model in relatively high correlation.

bioimpedance 신호를 이용한 하지동작 분석 (Analysis of leg movements using bioimpedance bignal)

  • 송철규;윤대영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.940-942
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot, and two potential electrodes are applied to the lateral aspect, medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

전위간섭을 기초로 한 병렬 접지봉의 합성접지임피던스의 분석 (An Analysis on Resultant Ground Impedance Based on the Potential Interference Of Parallel Ground Rods)

  • 이복희;성창훈;양순만
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.107-112
    • /
    • 2011
  • Multiple ground rods are commonly used to obtain the low ground impedance, but they will not reduce the ground impedance unless the spacings between the ground rods are sufficient. This paper presents the experimental results of frequency-dependent resultant ground impedance of two ground rods in parallel. The resultant ground impedance of two ground rods in parallel were measured as functions of the spacing and length of ground rods and the frequency of test currents and were discussed based on the potential interferences. As a consequence, the frequency-dependent ground impedance of single ground rod and two combined ground rods give capacitive. It was found that the effect of potential interference on the ground impedance is directly associated with the frequency-dependent ground impedance and is strong in low frequency. Also, in order to reduce the increasing rate of resultant ground impedance of two ground rods due to potential interference to within 10(%), two ground rods in parallel will be placed over one rod length apart.

전극길이 및 펄스반복율에 대한 부하임피던스 특성변화에 관한 연구 (A Study on the Characteristics of Corona Critical Voltage on Increasing Load Impedance)

  • 정종한;송우정;전진안;이유수;김휘영;김희제
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.184-186
    • /
    • 2002
  • In this paper, we studies EMTP analysis and characteristics of critical voltage of pulse corona and load impedance on variable electrode length. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a result, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

  • PDF

과도현상 해석을 위한 시간 영역에서의 등가축약법 :프로니 해석기법을 이용한 등가 구동점 임피던스 모델의 구성 (Time domain Reduction Method for Electromagnetic Transients Study: Equivalent Driving-Point Impedance Model using Prony Analysis)

  • 홍준희;박종근
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.687-690
    • /
    • 1994
  • This paper presents a method of obtaining transmission network equivalents from the network's response to the pulse excitation signal. Proposed method is base on Prony signal analysis and jtransfer function identification technique. As a result Thevenin-type of discrete-time filter model can be generated. It can reproduce the driving point impedance characteristic of the network.

  • PDF

Wavelet 변환을 이용한 고저항 지락사고 고장점 추정 (Fault Location Estimation for High Impedance Fault using Wavelet Transform)

  • 김현;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.369-373
    • /
    • 2000
  • High impedance fault(HIF) is defined as a fault that the general overcurrent relay can not detect or interrupt. Especially when HIF occurs in residential areas, energized high voltage conductor results in fire hazard, equipment damage or personal threat. This paper proposes a fault location estimation algorithm for high impedance fault using wavelet transform. The algorithm is based on the wavelet analysis of the fault voltage and current signals. The performance of the proposed algorithm is tested on a typical 154kV korean transmission line system under various fault conditions. From the tests presented in this paper it can be concluded that a fault location estimation algorithm using wavelet transform can precisely calculate the fault point for HIF.

  • PDF