온도와 풍속에 따른 태양광발전 효율 실증분석 연구 (A Study on Solar Power Generation Efficiency Empirical Analysis according to Temperature and Wind speed)

  • 차왕철;박정호;조욱래;김재철
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.1-6
    • /
    • 2015
  • Factors that have influence on solar power generation are specified into three aspects such as meteorological, geographical factors as well as equipment installation. Meteorological factors influence the most among the three. Insolation, sunshine hours, and cloud directly influence on solar power generation, whereas temperature and wind speed have impacts on equipment installation. This paper provides explanation over temperature-wind speed equation by calculating influence of temperature and wind speed on equipment installation. In order to conduct a research, pyranometer, anemometer, air thermometer, module thermometer are installed in 2MWp solar power plant located in South Cholla province, so that real-time meteorological data and generating amount can be analyzed through monitoring system. Besides, if existing and new methods are applied together, accuracy of prediction for generating amount is improved.

고속 UHF RFID 태그 검사 장비를 위한 전용 리더 (A Specialized Reader for High Speed UHF RFID Tag Inlay Inspection Equipment)

  • 배성우;박준석;성영락;오하령
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.63-69
    • /
    • 2014
  • RFIDs have not become widespread as expected partly due to the cost, size, read range, and reliability problems of tags. The success rate of reading must be improved in order for RFIDs to be widely adopted. Quality control of tags is crucial to meet this requirement. In this study, we designed and implemented a high-performance reader used in inspection equipment that conducts prior inspection of tags. To improve performance of the developed reader, the baseband modem and command processor (CP) were designed using H/W logic and implemented with FPGA. The inspection of small pitch inlays was made possible through the antenna shielding device and H/W command processor function. This equipment enables accurate evaluation of performance and identification of tags satisfying a given read range. By contributing to sort out defective tags, the results can ultimately lead to more stable RFID services.

Two Factors Failure Model of Oil-Paper Insulation Aging under Electrical and Thermal Multistress

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.957-963
    • /
    • 2014
  • Converter transformers play important roles in high-voltage direct current transmission systems. This paper presents experimental and analysis results of the combined electrical and thermal aging of oil-impregnated paper at pulsating DC voltages. Breakdown voltages and time-to-breakdown of oil-paper specimens were measured by using short-time and constant-stress tests. The breakdown characteristics of combined electrical and thermal aging on insulation system were discussed. According to the relationship between failure time and aging temperature, the two-parameter Weibull model was improved. On the basis of the competing risk algorithm and the improved Weibull model, the two factors failure model was calculated. And the influence of temperature in the insulation system has been analyzed. This model performs better than the two-parameter Weibull model when both time and temperature are considered as variables in estimating the lifetime of oil-paper insulation.

PI 관측기 기반 반도체 장비 모터의 궤적 추종 제어기 설계 (Trajectory Tracking Controller for Semiconductor Equipment Motors based on PI Observer)

  • 조윤성;최현준;전상민;신지훈;이재영;이범주;손영익
    • 반도체디스플레이기술학회지
    • /
    • 제22권2호
    • /
    • pp.96-103
    • /
    • 2023
  • This paper presents a robust position tracking controller for a motor used in semiconductor equipment, utilizing the motor angle measurement. Precise position control is challenging due to the presence of uncertainties in various motor applications. The proposed controller consists of a PD (Proportional-Derivative) controller and a PIO (Proportional-Integral Observer) to estimate the system's state and equivalent disturbance compensating for the uncertainties. Since the stability alternates as the observer gain increases, we have investigated it through the closedloop root locus under the system parameters change. The analysis has showed that the inertia of the motor is the main parameter that affects it, and by adjusting the control gain appropriately, the system can be rendered to be stable even when the inertia of the motor changes. The effectiveness of the proposed control algorithm is validated through computer simulations, followed by a comparison of its performance with the results of a previous study.

  • PDF

모바일 이용 가능형 ESMS 기능의 단상 분전반 개발 연구 (Development of Single Phase Cabinet Panel with Electrical Safety Monitoring System by Mobile)

  • 김기현;이상익;신성수;배석명
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.92-96
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the ESMS(electrical safety monitoring system) which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment are able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the ESMS and obtained certification. And we tested the over current, leakage current and arc under the normal condition.

캘리포니아 표준테스트 방법을 사용한 전기냉방기기의 가스냉방기기 대체에 따른 편익비용분석 (Benefit-Cost Analysis in Accordance with Replacement of Electrical Cooling System by Gas Cooling System using the California Standard Test)

  • 박래준;송경빈;원종률
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1774-1781
    • /
    • 2012
  • There are some efforts to improve the performance of electrical heat pump(EHP) and replace it with an alternative cooling equipment such as gas engine-driven heat pump(GHP), a gas cooling equipment, in order to solve the problem of summer electricity supply through reducing the summer electricity peak. This paper analyzes cost-benefit in accordance with replacement of electrical cooling system by gas cooling system using california standard test and sensitivity analysis of some scenarios.

시스 순환전류 저감장치의 과도특성 및 보호방식에 관한 연구 (A Study on the Transient Characteristic and Protection Schemes of Sheath Circulating Current Reduction Equipment)

  • 강지원;한용희;정채균;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권7호
    • /
    • pp.421-428
    • /
    • 2003
  • After the cable is installed, many geometric factors, such as bowing types of the cable and the length difference of the cable between each minor section will cause the impedance unbalance between cables. The impedance unbalance will increase or decrease the sheath circulating currents, which are critical to human safety and sustaining the capabilities of electric power. Accordingly, in this paper, a new method is also proposed to reduce the sheath circulating currents and an reduction equipment according to the theory of the new method is developed. The reduction equipment is tested when the cable is on service. The test results show that it can reduce the sheath circulating currents by up to 97.8[%]. This confirms the validation of the new method and the reduction equipment, and assures the safe operation of the transmission cables. In order to illustrate the safe operation of the cable with new current reduction equipment at transient state due to lightning and single line-to-ground fault, extensive simulations have been made. Then the protection scheme of sheath circulating currents reduction equipment is proposed by adopting the new device of RDP(Reduction Device Protector).

배전계통 기기 유지보수를 위한 RCM 모델 (Reliability-Centered Maintenance Model for Maintenance of Electric Power Distribution System Equipment)

  • 문종필;손진근
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.410-415
    • /
    • 2009
  • With the implementation of electric power industry reform, the utilities are looking for effective ways to improve the economic efficiency. One area in particular, the equipment maintenance, is being scrutinized for reducing costs while keeping a reasonable level of the reliability in the overall system. Here the conventional RCM requires the tradeoff between the upfront maintenance costs and the potential costs of losing loads. In this paper we describe the issues related to applying so-called the "Reliability-centered Maintenance" (RCM) method in managing electric power distribution equipment. The RCM method is especially useful as it explicitly incorporates the cost-tradeoff of interest, i.e. the upfront maintenance costs and the potential interruption costs, in determining which equipment to be maintained and how often. In comparison, the "Time-based Maintenance" (TBM) method, the traditional method widely used, only takes the lifetime of equipment into consideration. In this paper, the modified Markov model for maintenance is developed. First, the existing Markov model for maintenance is explained and analyzed about transformer and circuit breaker, so on. Second, developed model is introduced and described. This model has two different points compared with existing model: TVFR and nonlinear customer interruption cost (CIC). That is, normal stage at the middle of bathtub curve has not CFR but the gradual increasing failure rate and the unit cost of CIC is increasing as the interruption time is increasing. The results of case studies represent the optimal maintenance interval to maintain the equipment with minimum costs. A numerical example is presented for illustration purposes.

전력품질로 인한 아파트 수용가 승강기의 전기적 설비 영향에 관한 연구 (A Study on electrical equipment effect of apartment customer elevator by power quality)

  • 이희태;김재철;강장규;김기현;설규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.304-305
    • /
    • 2006
  • Now there is utilization of elevator increasing continuously, it is one of electrical facilities taking a serious view safety. However, elevator comfortable ride is researched generally Recently aging condition, equipment life, malfunction, other applicancies of power electronics and equipment disturbance effect on power quality and prevention measures are much researches in advanced nation. but awareness is lacking real condition up to now in domestic. Voltage sag, swell, harmonics, surge etc of elevator system is important problem about human safety. and there are many quality compensation to solve these problem of elevator. So to evaluate these problem, in this paper, displayed result through computer simulation for converter of problem, and inverter part by power quality problem in power distribution system.

  • PDF

PQ데이터를 이용한 예상 유지보수방안의 소개 (Concept of the Advanced Predictive Maintenance Using PQ Data)

  • 조수환;장길수;권세혁;전영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.396-398
    • /
    • 2006
  • Predictive maintenance is not an unfamiliar concept because it has been used to predict the failures of electrical equipment such as transformers, motors and so on. By thoroughly monitoring the status of individual equipment and tracing how the various characteristics change over time, we can be aware of its exact condition and prevent the impending failure by taking appropriate actions. In this paper, I will extend the concept of predictive maintenance for individual electrical equipment to the power distribution system and show how to use the data obtained from power quality monitors to improve the power system.

  • PDF