• 제목/요약/키워드: Electrical connector

검색결과 105건 처리시간 0.036초

Complex Permittivity Extraction of Blood Glucose at Microwave Frequency

  • Jeong, You-Chul;Lee, Hee-seok;Kim, Joung-ho
    • Journal of electromagnetic engineering and science
    • /
    • 제1권2호
    • /
    • pp.139-145
    • /
    • 2001
  • In this paper, a coaxial sample holder is proposed with its de-embedding and parameter extraction procedure. The S-parameters were measured up to 1 GHz using network analyzer, HP8753D, and N-type connector together with the de-embedding of N-type connector. The proposed de-embedding procedure is performed to extract electrical parameters of blood glucose, which gives the permittivity of blood glucose. We also analyzed the error of extracted parameters, which are caused by instrument error and geometrical error. Using these error analyses, we reduced the error factors of extracted parameters. We extracted electrical parameters of glucose samples through these all extraction procedure and confirmed the possibility of glucose diagnosis system based on microwave system.

  • PDF

Cu-Ni-Si-P 합금의 기계적 및 전기적 성질에 미치는 첨가원소의 영향 (The Influence of Alloying Elements Addition on the Electrical and Mechanical Properties of Cu-Ni-Si-P Alloy)

  • 김승호;염영진;박동환
    • 열처리공학회지
    • /
    • 제27권1호
    • /
    • pp.1-9
    • /
    • 2014
  • For connector material applications, the influence alloying elements of Mn, Cr, Fe, and Ti and cold rolling reduction on the mechanical property, electrical conductivity and bendiability of Cu-Ni-Si-P alloy was investigated. The hot rolled plates were solution treated at $980^{\circ}C$ for 1.5 h, quenched into water, cold rolled by 10% and 30% reduction in thickness, and then aged at $440{\sim}500^{\circ}C$ for 3, 4, 5 times. respectively. Cu-Ni-Si-P-x alloys cold rolled by 10 reduction before heat treatment have a good bendability compare to cold rolled by 30 reduction. Cu-3.4Ni-0.8Si-0.03P-0.1Ti shows the peak strength value of 759 MPa, an electrical conductivity of 39%IACS, an elongation of 10% and a hardness of 256 Hv aged at $440^{\circ}C$ for 6 hrs. Thus it is suitable for lead frame and connector.

순환전류에 대한 전철설비 보호카바 개선 연구 (A study on better wire protector of equipment on the Circulating Current in Catenary System)

  • 강승욱;김인철;김효진;김대식;백성현;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.375-378
    • /
    • 2007
  • In these days, Korea Railway apply simple catenary system to general lines and high speed lines of Korea Electric Railway. Circulation Current in catenary system frequently bring undesirable consequences. Namely, the Connector wire has many problems according to a flow of excessive circulation (or traction current) and a sudden rise of temperature on catenary when electric car or locomotive is running in high speed. The occurrence of events by the load increasement do considerable damages to peoples, organizations and systems. On a case by case accidents, the reeltype protective cover as part of various methods has some problems. In this project, we proposed the improved changes on the catenary system of a improvement and change of a messenger wire protector, improvement of connector wire's institution angle and of a replacement the connector wire with a dropper. Its tridimensional space limitation dictated the scale of the $32{\times}{\Phi}55$ to be as small as possible. It is easier to install than work by the existing cover on the messenger wire.

  • PDF

5.5kW이하의 소형분쇄기 차단기 접속부의 접촉불량에 의한 전압강하 및 열적 특성 분석 (Analysis of Voltage Drop and Thermal Characteristics for Poor Connections at Electrical Connector of Circuit Breaker of Small Size Pulverizer below 5.5kW)

  • 김상철
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.26-31
    • /
    • 2015
  • This paper describes the characteristics of voltage drop and thermal for poor connection on electrical connector of circuit breaker in control box of small size pulverizer. In order monitor, we did the changes of RMS in voltage and temperature value with video and made normal state over $2.5N{\cdot}m$ and poor connections state below $0.2N{\cdot}m$ by screw gage. In case of voltage signal, the voltage drop was increased when the current was increased due to poor connections. In case of temperature signal, the temperature difference indicates ten times at 5A and fourteen times at 15A in the normal state. According to increase thermal energy, the insulation of electrical wiring and connector of circuit breaker can be carbonized. The results of this study will be useful to the development of preventive devices and system for electric fire by poor connection at small size pulverizer.

커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석 (Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector)

  • 김상철;김두현;강신욱
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.

ABS 모듈의 접속부 및 전원배선 손상으로 인한 차량화재 사고사례 분석 (Analysis on the Fire Accident of Vehicle Due to Damage of Connector and wiring on an Anti-lock Brake System(ABS) Module)

  • 박남규;김진표;남정우;박종택;송재용
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.13-19
    • /
    • 2017
  • In this paper, study of vehicle fire cases caused by connector and power wiring of anti-lock brake system(ABS) module damage is presented. The purpose of ABS module is to improve braking and steering ability under sudden stop of the vehicle by repeatedly activating and releasing the brake with electric signal via electric control unit. The electric control unit for ABS may experience incomplete contact between power line and signal line or electrical breakdown on the printed circuit board by undergoing repetitive signal change which would consequently result in electrical heat and spark, eventually leading to automotive fire. Therefore, the purpose of this paper is to provide fundamental data by analyzing connector and power wiring of ABS module damage conducive to the precise investigation on the cause of vehicle fire.

Connector용 Cu-Ni-Si-P합금의 특성에 미치는 Ni및 Si의 영향에 관한연구 (A Study on the Influence of Ni and Si Content on the Characteristics of Cu-Ni-Si-P Alloy for Connector Materials)

  • 노한신;이병우;이광학;김홍식
    • 한국재료학회지
    • /
    • 제4권8호
    • /
    • pp.877-887
    • /
    • 1994
  • 강도, 소전율, 스프링성, 내열성 및 굽힘 가공성등의 적절한 조화를 갖는 콘넥팅재료를 개발하기 위하여 Cu-Ni-Si-P합금에 대하여 연구하였다. Ni와 Si의 조성을 달리한 3종류의 합금을 용해, 주조하여 약 $900^{\circ}C$에 열간압연 후 수냉하고, 그 후 냉간압연하여 $450^{\circ}C$. $500^{\circ}C$$550^{\circ}C$에서 시효처리한 후 기계적 성질 변화와 도전율 등을 조사하였다. 고강도와 고존도율의 적절한 조화를 나타내는 Cu-2.7%Ni-0.53% Si-0.029%P 합금을 만들었다. 합금 1을 0.5mm두께의 콘넥팅재료로 가공한 후 여러가지 특성은 인청동(C 5210R-H)과 황동(C2600R-EH)에 비해 우수한 것으로 평가되었다.

  • PDF

시효 열처리에 따른 Cu-Be 합금의 전기.기계적 특성 고찰 (The Influence of Aging Treatment on the Mechanical and Electrical Properties of Cu-Be Alloy)

  • 류민;이병수;정봉용;김명호
    • 한국주조공학회지
    • /
    • 제31권6호
    • /
    • pp.366-370
    • /
    • 2011
  • The influence of aging treatment on the microstructure, mechanical and electrical properties of Cu-Be alloy for connector material applications was investigated. The properties of mechanical strength and electrical conductivity were found to increase with increasing aging temperature. By the way, SEM/EDS and TEM analysis exhibited that beryllides precipitation (CoBe and NiBe) with a size of 50 nm were distributed in grains. It was, therefore concluded that these beryllide precipitates improved the mechanical strength and also it was favor in increasing of electrical conductivity.

궤도차량 변속오류 예방을 위한 품질개선 (Quality Improvement to Prevent Shifting Error of Tracked Vehicles)

  • 윤성현;백현무;박동민;오동교
    • 품질경영학회지
    • /
    • 제51권2호
    • /
    • pp.297-313
    • /
    • 2023
  • Purpose: The purpose of this study is to investigate the causes of shifting errors reported in military tracked vehicles and to improve related quality to prevent recurrence. Methods: A systematic disassembly and inspection of the transmission is carried out and an experimental simulation is conducted to reproduce the shifting error phenomenon. Electrical characteristic tests are subsequently performed and microscopic observation is also carried out on the disassembled connector parts such as pins and fractured surfaces. Results: Oil contamination and swelling deformation are observed in the connector to the vehicle due to oil leakage of its counterpart connector to the transmission. This causes electrical contact failure between both connectors in the fastened state, and it is found that shifting error of the tracked vehicle could occur subsequently. To prevent the recurrence of this phenomenon, comprehensive quality improvement is conducted including product improvement of the wiring harness assembly and strengthening activities for quality control and preventive maintenance. Conclusion: This study is expected to be helpful as a prior case study for cause analysis and recurrence prevention in the event of similar cases in the future.

금구류 히트사이클 시험용 자동 저항측정 시스템 개발 (Development of Automatic Resistance Measuring System for Aluminum Connector)

  • 박성균;손화영;류재남;김경환;박병락;박충열;김언석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.161-163
    • /
    • 1997
  • Heatcycle testing for aluminum connector is very important. But because of connecting or disconnecting the test circuit, measuring resistance is difficult. Also the previous measuring resistance instrument is analog type. So measuring method is difficult. And four measuring points for one test circuit cause difficulty in automation. In this paper we developed the automatic system for measuring resistance. Automation will allow more information to be gathered, which will lead to the connector aging process being better understood and controlled.

  • PDF