• 제목/요약/키워드: Electrical apparatus

검색결과 694건 처리시간 0.03초

Electrical Properties of High Tc Superconductors Using the Pyrolysis Method for Renewed Electric Power Energy

  • Lee Sang-Heon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권5호
    • /
    • pp.217-220
    • /
    • 2005
  • We have fabricated a superconducting YBCO system according to the pyrolysis method and low pressure apparatus. In our experiment, the X-ray diffraction pattern of the non doped YBaCuO layer indicated that the superconductor contained only 90K phase crystal. The critical temperature and critical current density for a thick layer at $650^{\circ}C$ were Tc=90 K and $Jc=6{\times}10^{4}A/cm^2$ at 90K. In low pressure apparatus, the 90 K phase YBaCuO was grown at a lower temperature compared with the normal system. Tc and Jc at $650^{\circ}C$ were Tc = 90 K and $Jc=6{\times}10^{4}A/cm^2$ at 90K.

도로조명용 프로그램과 노면특성 장치의 개발 (Development of the Program Road lighting Road Surface Property Measuring Apparatus)

  • 김기훈;;심상만;김훈
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.133-133
    • /
    • 1999
  • Average illuminance and luminance can be calculated by graphical methods to a certain extent but to calculate for a wide place a suitable software is needed. Softwares suitable for this purpose have been already developed in foreign nations, but the appropriate softwares for domestic use have not been developed. Therefore a program is developed which is executable in Hangul Windows. The softwares LAPRoad, is developed to calculate luminance and illuminance distribution of road surface, as well as average luminance and illuminance, overall uniformity, longitudinal uniformity, threshold increment veilling luminance and glare. And an apparatus that measures road surface reflection properties is developed. Because the road surface reflection properties is very important in luminance calculation, then concrete road surface reflection properties were measured.

건전지의 방전에 의한 폭발성 가스의 점화에 관한 실험적 연구 (Experimental Study on Ignition of Flammable Gas by Spark of Dry Battery)

  • 이춘하;송현직;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1543-1546
    • /
    • 1994
  • Ignitabilility of explosive gas mixture by spark of dry cell in case of short circuit by accident was studied for the purpose of evaluation of intrinsically safe characteristics of dry cell that manufactured in Korea. IEC type spark test apparatus, $21{\pm}2$ Vol% of hydrogen - air mixture, and dry cell that produced in Korea was used for the experiment. The result of this research could be used for design, manufacturing, and using the intrinsically safe electrical apparatus.

  • PDF

대전력시험의 새로운 측정시스템에 대한 불확도 평가 (The estimation of uncertainty in new measuring system used for high-power tests)

  • 서윤택;김맹현;김대원;강영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.540-542
    • /
    • 2003
  • In the high-power tests to be performed on electrical apparatus as circuit-breaker, load switch, fuse, transformers, insulators, cable and so on, the results of tests on these apparatus are extremely important to evaluate the performance of test object. The reliability of the results depends on the reliability of measuring systems used in the laboratories where tests are performed. This paper deals with factors of uncertainty and describes estimation of uncertainty in new measuring system used in high-power testing LAB. 1 in KERI.

  • PDF

동력저장장치가 적용된 복합발전시스템의 개발 (Development of combined generation systems that power storage apparatus is applied)

  • 이정일;서장수;강병복;차인수
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.169-174
    • /
    • 2002
  • The developments of the solar and the wind power energy are neccessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of existing problems, combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

에폭시 경화물 DSC에 의한 유리전이 온도 측정의 분석조건 의존성 (The Effect of DSC Analysis Condition on the Glass Transition Temperature of curred Epoxy This paper studies on the effect of DSC(Differential Scanning Calorimeter) analysis condition on the glass transition temperature of silica filled epoxy network polymer used for ultra-high voltage apparatus. The effects of temperature scanning rate specimen size and gas flow rate on measured glass transition temperature have been studied in order to select optimum thermal analysis condition.)

  • 오무원;권혁삼
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.30-33
    • /
    • 1994
  • This paper studies on the effect of DSC(Differential Scanning Calorimeter) analysis condition on the glass transition temperature of silica filled epoxy network polymer used for ultra-high voltage apparatus. The effects of temperature scanning rate specimen size and gas flow rate on measured glass transition temperature have been studied in order to select optimum thermal analysis condition.

  • PDF

옥내용 에폭시 수지의 열화 특성 (Degradation Properties of Epoxy Resin Used in Indoor)

  • 남기동;정중일;연복희;허창수;박영두
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2000
  • In this paper, study on the properties of the thermal degradated epoxy resin which is used in indoor insulation apparatus is performed to investigate the problems of the decreasing insulation characteristics and crack in the indoor insulation apparatus. As a parameter of variation, SEM, contact angle, surface resistivity, relative dielectric constant and weight loss are measured. As the results of the above measurements, the contact angle and surface resistivity of the epoxy resin has increased to 200$^{\circ}C$ in but at the above 200$^{\circ}C$ the values have decreased. The relative dielectric constants the thermal treated samples have increased on with the temperature increase. We find the volatile components of the epoxy resin compound has disappeared during thermal degradation by SEM. The insulation properties of the epoxy resin have increased by the 200$^{\circ}C$ but decreased in the above 200$^{\circ}C$.

  • PDF

지하철과 전력선의 누설전류 측정을 위한 저장형 데이터 계측장치 (DATA LOGGER APPARATUS FOR MEASUREMENT STRAY CURRENT OF SUBWAY AND POWER LINE)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.731-734
    • /
    • 2003
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.

  • PDF

초음파 기술을 이용한 실리콘 이방성 식각 공정에서의 표면 평탄화 향상 연구 (Surface Flatness Improvement in Si Anisotropy Etching Process Utilizing Ultrasonic Wave Technology)

  • 윤의중;김좌연;이강원;이석태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.416-417
    • /
    • 2005
  • In this study, we optimized the process of Si anisotropy etching by combing tetramethyl ammonium hydroxide (TMAH) etching process with ultrasonic wave technology. New ultrasonic TMAH etching apparatus was developed and it was used for fabricating a $20{\mu}m$ thick diaphragm for Si piezoresistive pressure sensors. Based on comparison study on etch rate and surface flatness, it was observed that the Si anisotropy etching methode with new ultrasonic TMAH etching apparatus (at 40 kHz/ 500 watt) was superior to conventional etching methods with TMAH or TMAH+ammonium persulfate(AP) solutions.

  • PDF

Electrical Properties of the Epoxy Nano-composites according to Additive

  • Shin, Jong-Yeol;Park, Hee-Doo;Choi, Kwang-Jin;Lee, Kang-Won;Lee, Jong-Yong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권3호
    • /
    • pp.97-101
    • /
    • 2009
  • The use of a filler material in epoxy composite materials is an essential condition for reducing the unit cost of production and reinforcing mechanical strength. However, the dielectric strength of insulators decreases rapidly due to interactions between the epoxy resin and filler particles. In contrast to existing composite materials, nano-composite materials have superior dielectric strength, mechanical strength, and enduring chemical properties due to an increase in the bond strength of the polymer and nano material, It is reported that nano-fillers provide new characteristics different from the properties of the polymer material. This study is to improve the insulation capability of epoxy resins used in the insulation of a power transformer apparatus and many electronic devices mold. To accomplish this, the additional amount of nano-$SiO_2$ to epoxy resin was changed and the epoxy/$SiO_2$ nano composite materials were made, and the fundamental electrical properties were investigated using a physical properties and an analysis breakdown test. Using allowable breakdown probability, the optimum breakdown strength for designing an electrical apparatus was determined. The results found that the electrical characteristics of the nano-$SiO_2$ content specimens were superior to the virgin specimens. The 0.4 wt% specimens showed the highest electrical properties among the specimens examined with an allowable breakdown probability of 20 %, which indicates stable breakdown strength in insulating machinery design.