• 제목/요약/키워드: Electrical Linear Generator

검색결과 165건 처리시간 0.02초

Free-Piston 엔진용 평판형 선형 발전기를 이용한 기동모드 해석 (Starting Mode Analysis of Flat-type Linear Generator for Free-Piston Engine)

  • 김영욱;임재원;정현교
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.966-971
    • /
    • 2008
  • Free-piston engine system is a new type energy converter which uses a linear motion of piston by using linear generator. In free-piston engine system, the piston is not connected to a crank-shaft. The major advantages of free-piston engine system are high efficiency and low mechanical loss from the absence of motion conversion devices. Linear generator of free-piston engine system is used as generator and starting motor. In design step, considering of back-emf and detent force characteristics for generating mode and thrust and control characteristics for starting mode is needed. In this research, generating mode of flat-type linear generator and tubular-type linear generator is analyzed by finite element analysis method and starting mode of both type linear generators is analyzed by using capability curve. Capability curve is plotted from electrical parameters of both type linear generator and motion profile is calculated from mechanical parameters.

Analysis and Experiments of the Linear Electrical Generator in Wave Energy Farm utilizing Resonance Power Buoy System

  • Park, Sang-Shin;Park, Se Myung;Jung, Jongkyo;Kim, Jin Ho
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.250-254
    • /
    • 2013
  • In this research, the linear electrical generator in wave energy farm utilizing resonance power buoy system is studied. The mechanical resonance characteristics of the buoy and the wave are analyzed to maximize the kinetic energy in a relatively small wave energy area where WRPS is operated. In this research, we chose an analog model of the linear electrical generator of which size is one-hundredth of an actual size of it in WPRS (Wave energy farm utilizing Resonance Power buoy System) prior to verifying the characteristics of actual model of linear electrical generator in WRPS. In addition, the finite element analysis is conducted using commercial electromagnetic analysis software named MAXWELL to examine the electric characteristic of linear generator. Finally, for the verification of dynamic and electric characteristics of linear generator, the prototype was manufactured and the experiments to measure the displacement and the output electric power were performed.

Optimization and Thrust force Calculation of Linear Generator in Starting Mode for Free-Piston Engine Applications

  • Lee, Hyun-Woo;Eid Ahmad M.;Sugimura Hisayuki;Choi, Kwang-Ju;Nakaoka Mutsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.395-398
    • /
    • 2006
  • this paper provides a novel method to start the linear engine coupled linear generator from dead stop to its final steady state operation. This method depends mainly to use the linear generator mounted on the shaft of the linear engine to provide the required thrust force to move and oscillate the linear engine from bottom to top dead centers. It is a cost effective approach to start the internal linear combustion engine using its coupled tubular permanent magnet linear generator proposed here. This linear generator operates in this case in motoring mode, providing the required thrust force by feeding this linear generator phases with currents by using a three phase PWM inverter controlled by position feedback scheme. In order to provide the desired thrust force with specific value and direction, a position feedback is required to control the free piston engine motion through controlling the inverter switches using PWM control scheme.

  • PDF

수소연소 선형 발전기의 초기 기동 (Starting operation of a linear generator driven by a hydrogen engine)

  • 정승기;김경수;최준영;오시덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.110-112
    • /
    • 2008
  • A linear generator driven by a hydrogen combustion engine has been developed. Unlike rotary engine-generator systems, the linear counterpart is inherently unable to start by itself unless external force is provided for initial compression/ignition cycle. When the generator is connected to utility power lines through a bidirectional power conversion system, however, the self start-up can be done by driving the generator as a motor. This paper introduces a prototype 1kW linear hydrogen engine-generator system being developed and shows the self start-up is possible with proper motoring mode.

  • PDF

수소연소 리니어 발전기의 초기 구동방안 (Starting of a Linear Generator Driven by a Hydrogen Engine)

  • 정승기;김경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.198-200
    • /
    • 2007
  • A linear generator driven by hydrogen (or other kind of fuel) combustion engine requires special consideration for starting because of its none-conventional way of operation. This study investigates the possibility of replacing mechanical (hydraulic) start-up with electrical motoring. Simulation study based on 1 kW prototype system shows that the mover position of a linear generator can be controlled with a proper current control of power converter.

  • PDF

정수장 마이크로 소수력 발전기 적용에 대한 연구 (A Study on the Application of Micro Hydro Power Generator at the Water Treatment Plant)

  • 김종겸;박영진;김일중
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.67-72
    • /
    • 2014
  • Inflow or outflow from the water treatment plant and the sewage water has potential energy. If this potential energy can be converted into electrical energy by water turbine generator, it can help to save energy because of the high capacity utilization. So recently, micro hydro power plant is reviewed in the water treatment facility. If generation capacity is low, induction generator is primarily used. If output capacity is low, generated power is supplied to the inside load. Induction generator can cause voltage drop by the inrush current at a start-up and requires reactive power for magnetization. In this study, we analyzed the flow of power and voltage variation against inrush current that occurs when the induction generator starts under the terms that loads of linear and non-linear of the water purification plant are used. Analysis results are that the voltage drop is within an allowable range and the power factor is slightly reduced by the need of reactive power.

PERFORMANCE AND DESIGN OF A SINGLE-PHASE LINEAR SYNCHRONOUS GENERATOR USING FINITE ELEMENT METHOD

  • Eid, Ahmad M.;Kim, Sung-Jun;Kang, Ju-Sung;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.95-99
    • /
    • 2005
  • This paper presents a general proposal to design and calculate the performance of a tubular permanent magnet linear generator treated here on the basis of the Finite Element Method. Optimizing the linear generator dimensions reduces the cogging force, which occurs due to the interaction between stator teeth and the permanent magnets. The generated AC voltage is analyzed and evaluated for both no load and load cases to take the armature reaction effects on the air gap flux density. A repetitive routine is followed to calculate the output AC voltage from the change of flux and the speed of the single-phase linear generator. The AC output voltage is calculated for different resistive loads, and hence, the linear generator load characteristic is obtained. The designed linear generator is capable to generate an output power of 5.3kW with AC output voltage of 222V with an efficiency of 96.8% at full load of 23.8A. The full load current is chosen based on the thermal properties of the coil wire insulations.

  • PDF

Design Rules of Hybrid Stepping Machine for Free Piston Engine

  • Jeong, Sung-In
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1219-1226
    • /
    • 2017
  • This paper presents the hybrid stepping machine for linear oscillating generators. The focus of the work is the suggestion of the improved model through the comparison of proposed models ; new flux concentrating PMs mover of the hybrid stepping generator is proposed based on the symmetrical and non-symmetrical stator cores of the surface mounted PMs mover, and non-slanted PMs and slanted PMs of the flux concentrating PMs mover. It is achieved using equivalent magnetic circuit considering leakage elements. Finally, this study suggests new hybrid stepping structure of linear oscillating generator.

전력계통 동기발전기의 T-S Fuzzy 모델링 (T-S Fuzzy Modeling of Synchronous Generator in a Power System)

  • 이희진;백승묵;박정욱
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1642-1651
    • /
    • 2008
  • The dynamic behavior of power systems is affected by the interactions between linear and nonlinear components. To analyze those complicated power systems, the linear approaches have been widely used so far. Especially, a synchronous generator has been designed by using linear models and traditional techniques. However, due to its wide operating range, complex dynamics, transient performances, and its nonlinearities, it cannot be accurately modeled as linear methods based on small-signal analysis. This paper describes an application of the Takaki-Sugeno (T-S) fuzzy method to model the synchronous generator in a single-machine infinite bus (SMIB) system. The T-S fuzzy model can provide a highly nonlinear functional relation with a comparatively small number of fuzzy rules. The simulation results show that the proposed T-S fuzzy modeling captures all dynamic characteristics for the synchronous generator, which are exactly same as those by the conventional modeling method.

3상 집중권 권선을 갖는 코어리스/코어드 타입 리니어 발전기의 공간고조파 해석법을 이용한 전기자 반작용 자계특성 해석 (Comparison and Analysis of Armature Reaction Magnetic Field of Linear Generator with Coreless/Cored Type Three Phases Concentrated Winding by using Space Harmonic Analytical Method)

  • 서성원;구민모;강한빛;최장영
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.64-71
    • /
    • 2015
  • This paper deals with analysis of armature reaction magnetic field of linear generator with three phases coreless/cored type concentrated winding. On the basis of a magnetic vector potential and Maxwell's equations, governing equations to predict armature reaction field are derived, and current density modeling is also performed analytically by using the Fourier series expansion. The analytical method used in this paper is confirmed by comparing with finite element analysis results.