• Title/Summary/Keyword: Electrical Installations

Search Result 161, Processing Time 0.026 seconds

Real Time Monitoring and Management Method for Electrical Safety of Customer Electrical Installations Connected to Smart Grids (스마트그리드 연계 고객전기설비 전기안전 실시간 감시 및 관리 방안)

  • Jeon, Jeong-Chay;Park, Chan-Eom;Lim, Young-Bae;Bae, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.340-344
    • /
    • 2010
  • In order to achieve purpose of Smart Grids, which is effective use of electrical energy, the safety of electrical installations must be secured. This paper presented real time monitoring and management method for electrical safety of customer electrical installations connected to Smart Grids. And the direction of electrical safety system for the introduction of real time monitoring and management method was suggested. Efficiency improvement of electrical safety management and new supplementary services related with Smart Girds will be available by introducing the presented method.

A Study on the Present State and Consistent use of Terminologies Concerning Grounding (접지에 관한 용어의 실태와 일관성 있는 사용을 위한 고찰)

  • Lee, Bok-Hee;Lee, Kang-Hee;Kim, Tae-Ki;Kim, Han-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.81-87
    • /
    • 2013
  • A grounding scheme is one of important parts in protection for safety of electrical installations. Terminologies are successively creating and gradually increasing due to diversity and external environments. The declaration and definition of terminologies concerning grounding are in disorder in several KS standards, electrotechnical provisions for electrical installations and electrotechnical guides related to electrical installations. There seem to be serious confusions in use among technicians and experts. In this paper, we proposed a new scheme and system to consistently use the technical terms concerning grounding described in KS standards and technical provisions. Different use examples and the present state of terminologies on grounding described in Korean documents such as KS IEC standards, technical provisions for electrical installations, consumer's electrical installation guide, and etc are investigated. Although the scope of this work is limited to examine the terminologies on grounding, it is expected that the proposed method could be contributed to the consistent use of terminologies in all areas in KS C IEC standards and technical provisions for electrical installations.

A Study on the analysis of actual state and establishment method of the power source installations in the entertainment spaces (공연장 전원설비의 현장실태분석 및 시설방식에 관한 연구)

  • Yi, G.H.;Bae, S.M.;Kim, H.S.;Gil, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1707-1709
    • /
    • 2003
  • This paper deals with the analysis of actual state and establishment method of the power source installations in the entertainment spaces. This paper shows the result that investigate actual state of the power source installations in the entertainment spaces. In this paper, in other to improve the safely and authoritativeness of entertainment spaces, an author propose establishment method of the power source installations in consideration of the special quality of stage equipments.

  • PDF

International Standards of IEC TC64 & TC99 apply to Technical Regulation in Korea Electricity Business Act (전기설비기술기준에 도입되는 IEC TC64 및 TC99 규격)

  • Kim, Kwang-Deok
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.220-222
    • /
    • 2004
  • The IEC standards related to the Technical Regulation in Korea Electricity Business Act are classified into the standards/guides for electrical system and the specifications for electrical equipment/materials. IEC Standard 60364 "Electrical Installations of Buildings" and IEC Standard 61936 "Power Installations Exceeding 1 kV AC" prepared by IEC Technical Committee(TC) 64 and TC 99 respectively, are representative standards for electrical installations of buildings, substations, industrial plants, etc.

  • PDF

Judgement of the need for Over-Voltage Control of the Low-Voltage Electrical Installations (저압 전기설비의 과전압 억제 필요성 판단)

  • Lee, Ju-Cheol;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.91-96
    • /
    • 2015
  • There are provision for risk analysis in IEC standards. It is to determine the need for installation of a surge protection device (SPD) in order to protect the low-voltage electrical installations from overvoltages caused by atmospheric phenomena and the like. However, scattered many related standards, the lack of details are not easy to apply it in the field. We investigated the relevant domestic and international standards for applies to the international standards in domestic. And we proposed the flow chart for determining the need for protection of the low-voltage electrical installations from overvoltage due to atmospheric phenomena and it set the appling target facility.

The Analysis of Field Condition for Power Receiving System and Patch and Panel Boards at Construction Sites (건설현장의 수전설비 및 배.분전반의 현장실태 분석)

  • Gil, Hyoung-Jun;Han, Woon-Ki;Kim, Hyang-Kon;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.335-340
    • /
    • 2004
  • To analyze risk factors of temporary power installations, the investigation was carried out for power receiving system and pack and panel boards at construction sites. The subject was variable such as an airport, an apartment, a municipal playground. There are many risk factors caused by inadequate working environments and the deterioration of temporary power installations using equipment with minimum safety devices at construction sites. There, it is intended to present problems and preventive measures against electrical shock accidents, through analyzing risk factors of real field condition and investigating temporary power installations all over the country.

  • PDF

The Investigation and Analysis of Field Condition on the Electrical Shock Hazard of Electrical Facilities Used for Temporary Power Supply at Construction Site (임시전력 건설현장에 사용되는 전기설비의 감전위험에 관한 현장실태 조사 및 분석)

  • Gil, Hyoung-Jun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.197-204
    • /
    • 2004
  • The temporary power installations are to be used for temporarily supplying power during work at construction sites and have a minimum of protective devices to differ from permanent installations. There are many risk factors caused by loose working environments, deterioration of installations at construction sites. To analyze risk factors of temporary power installations, the investigation and the questionnaire were carried out side by side for power receiving system patch and panel boards, and were performed by researcher, the related expert, engineer of Korea Electrical Safety Corporation all over the country. The objects were variable such as an airport, an apartment, a municipal playground As a result, there are many problems such as a bad lock, poor protection of charging department. Solvable methods are improvement of the related regulation safety education, safety check and so on. In the future, the analytical data can be applied to prevent the electrical shock at construction site, and can be used to stabilize electrical installations.

Performance based Construction Specifications and Design Criteria Development Plan of Electrical Installations (건축전기설비분야의 성능중심 건설기술기준 작성 지침 개발)

  • Kim, Se-Dong;Lee, Kwang-Sik;Choi, Eun-Hyeok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.209-212
    • /
    • 2007
  • It is increased electrical energy consumption with the development of intelligence society in buildings and thus an energy conservation through efficient use of electricity and reliability, safety, etc became more important. This research paper intensively investigated performance based construction specifications and design criteria of electrical installations in domestic and foreign country. It is necessary to analyze the key features based on performance and general trend about contractor guarantee, warranty method, performance design criteria from the investigated data. This paper shows a reasonable performance based construction specifications and design criteria of electrical installations.

  • PDF

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

Assessment and Management Method of Flicker Emission Level Based on IEC 61000-3-7 for Domestic Extra-high Voltage Customers (국내 특고압 고객에 대한 IEC 61000-3-7 기반의 플리커 방출한계 평가 및 관리 방안 연구)

  • Han, Su-Kyoung;Shin, Hoon-Chul;Park, Sang-Ho;Kim, Kern-Joong;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • IEC 61000-3-7 provides guidance for limiting flicker and enabling the connection of fluctuating load installations, that is, producing flicker in MV, HV and EHV power systems. In Korea, the flicker have been restricted by Japanese standard of ${\Delta}V_{10}$ method. ${\Delta}V_{10}$ was developed only for arc furnaces in 1960's. And now it is revealed that it is not suitable for application to other fluctuating load installations through many researches. $P_{st}$ which is a flicker index used in IEC 61000-3-7, indicates visual inconvenience due to voltage fluctuation across large range of frequency and can be applied to fluctuating load installations as well as arc furnaces. In this paper, we introduce how to calculate and assess flicker emission level for the individual fluctuating load installations connected in EHV system and how to manage the emission levels in the power system according to IEC 61000-3-7.