• Title/Summary/Keyword: Electrical Installation

Search Result 6,497, Processing Time 0.025 seconds

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.

Leakage Currents Flowing through Lightning Surge Arresters under Various Fault Conditions in Receiving and Distribution Power Systems (수배전계통의 여러 가지 고장조건에서 피뢰기에 흐르는 누설전류)

  • Lee, Bok-Hee;Kil, Hyeong-Joon;Kang, Sung-Man;Choi, Hwee-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.132-139
    • /
    • 2004
  • Unsymmetrical faults are classified into single line-to-ground faults, line-to-line faults, or double line-to-ground faults in receiving and distribution power systems. Many of overhead distribution-line faults are single line-to-ground faults, and lightning surge arresters are stressed by system frequency overvoltages due to unsymmetrical faults. In this work, the unsymmetrical faults in receiving and distribution systems were experimentally simulated, and the characteristics of total leakage current flowing through lightning surge arresters due to various unsymmetrical faults were investigated. As a result, a little variations of the leakage current flowing through Zinc oxide (ZnO) surge arresters in the range of $\pm$10[%] voltage regulations were observed. It could be concluded that the unsymmetrical faults have no effect on the long-term life performance of ZnO surge arresters in effective grounding systems. On the other hand, the magnitude of the leakage current flowing through ZnO surge arrester elements under single line-to-ground faults was more than 140 times as compared with that under normal operating voltages in ineffective grounding systems. But abnormal voltages caused by line-to-line faults and double line-to-ground faults have a little effect on total leakage current of ZnO surge arrester elements.

Sensibility Evaluation on the Correlated Color Temperature in White LED Lighting (백색 LED 조명의 색온도에 관한 감성평가)

  • Jee, Soon-Duk;Lee, Sang-Hyuk;Choi, Kyoung-Jae;Park, Joung-Kyu;Kim, Chang-Hae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.1-12
    • /
    • 2008
  • The aim of this study is to investigate the sensitivity evaluation of human beings in reacting to the correlated color temperature of the optical properties of white LED lighting. For the sake of this study, white light-emitting diode modules have been fabricated their correlated color temperature have been measured, test cabinets for the sensitivity evaluation have been constructed with the white LED modules, and their sensitivity reactions on the test cabinets have been evaluated and analyzed. The sensitivity reaction has been evaluated by the semantic differential method with 15 selected questions, and the reliability and the content validity of their lighting have been analyzed to 3 factors which foe the activity as the first factor, the stability as the second one, the potency as the third one, respectively. For the data analysis on the sensitivity reaction, the dependent variable is the score of the sensitivity evaluation and the independent one is the correlated color temperature of the test module. The results of this study is as follows: In the case of the sensitive evaluation on the activity and the potency in the white LED lighting compared with the fluorescent lamp, the subjects have made higher mark on $MA_3$ with 8,300[K], and in the factor of the stability, they have made higher mark on $MA_1$ with 3,800[K].

A Development of on Instrument for Measuring Glare Sensation in the Visual Field (시야내의 글레어감각 측정용 기기의 개발)

  • Park, Sung-Ryul;Kim, Jeong-Tai;Kim, Won-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2009
  • Discomfort Glare from the artificial light sources is an important issue in assessment of lighting quality for healthy buildings. Glare, as a factor of the characteristics of brightness, which has been defined as the sensation produced by contrast and luminance within an entire field view, unfavorably influences the occupants who performs visual tasks. It may cause annoyance and discomfort by interruption of visibility. In the whole visual field, glare can be determined by effects of the position, the luminance and the size of the light source and brightness of the surroundings. Therefore, experimental equipment is required to maintain a constant visual lighting environment. Recent studies have been developed and used the instrument for glare sensation evaluation but the instruments showed some difficulties to verify the correlation of glare indicators. The instrument have been developed with reference to former studies. It is called the Glare Tester. This is consist of 2[m]-diameter vertical dome screen painted with white flat paint, and light sources installed inside the screen. These light sources can provide various range of brightness at any inner surface of the screen. 2 Glare light sources can provide the value of luminance within the range of $0{\sim}150,000[cd/m^2]$. Moreover, 12 light sources are used for background luminance and it can perform the value of luminance within the range of $0{\sim}350[cd/m^2]$. Several experiments have been conducted using this Glare Tester to evaluate the range of the visibility, the values of BCD and the glare sensation in lower and upper visual field.

Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP (T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석)

  • Lim, Geon-Gyu;Lee, Hyang-Beom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.159-165
    • /
    • 2008
  • In this paper the signal analysis of eddy current test using transmit-receive(T/R) pancake coil of ECT array probe using electromagnetic finite element method(FEM) is performed. For characteristics analysis, the notch defect is used. The depth of defect is 40[%] of steam generator tube thickness, and inside defect and outside defect are used as simulation examples. The signal analysis is performed according to the variation of receive coil position. The receive coil is positioned $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$ of circumferential position of transmit coil. To obtain e electromagnetic characteristics of robes, the governing equation is derived from Maxwell's equations, and the problem is solved using the 3-dimensional finite element method. The signal magnitude of inside defect is bigger than that of outside defect, and the signal difference can be seen according to the variation of position of receive coil. The experimental signal and numerical signal of ASME standard tube show similar results. The results in this paper can be helpful when the ECT signals from ECT array probe are evaluated and analyzed.

The Study of the Optical Current Sensor Using Magneto-Optic Effects (자기광학효과를 이용한 광전류센서에 관한 연구)

  • 전재일;이정수;송시준;정철우;박원주;이광식;김정배;김민수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.47-53
    • /
    • 2003
  • In this paper, we described the laboratory layout of the optical CT in connection with the measurement of large current based on Magneto-Optic Effects. It was used He-Ne laser for light source and was used PIN-Photodiode for light receiver. The sensing section was organized by winding optical fiber around conductor on the concept that the rotation angle of polarizing axis by Faraday Effect is proportional to the applied current in to conduction. The optical signal passed through optical fiber sensor was induced to analyzer arranged in the direction of $\theta$ for input polarization, and then analyzed its rotation angle and researched on operating characteristics of optical CT for 60[Hz] AC current measurement from l00[A] to 1000[A] was carried out. In this results, the output signals induced linearly with the current and proved that the intensity is increased with increasing turns of fiber through output differences which in accordance with turns of fiber and we verified that there is not only difference of the output with the medium between electric field and optical fiber, but also the lineality. Measuring the references and output intensities of the optical CT, ratio errors were within $\pm$7%. This confirmed that error rate will be improved by each medium and turns.

A Study on the Application of the DVR in AC Electric Traction System (전기철도계통에 순간전압강하 보상장치 적용에 관한 연구)

  • 최준호;김태수;김재철;문승일;남해곤;정일엽;박성우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.95-104
    • /
    • 2003
  • The electric traction systems are quite differ from general power systems which is single-phase and heavy load. Therefore, there are inevitably power quality problems such as steady state or transient voltage drop, voltage imbalance and harmonic distortion. Among these problems, since steady-state volatge drop is the one of most important factor in electric power quality, many researches about on the compensation of volatge drop by using SVC(Static Var Compensator) and/or STACOM(Static Compensator) have been studied and proposed Also, it is expected that transient voltage drop(voltage sag) could affect the control and safety of high speed traction load. In this paper, voltage sag compensation of AT(Auto Transformer) feeding system are studied The detailed transient models of utility source, scott transformer, AT, and traction load are estabilished. The application of DVR(Dynamic Voltage Restorer) in electric traction system is proposed to compensate the voltage sag of traction network which is occured by the fault of utility source. It can be shown that application of the DVR in electric traction system is very useful to compensate the volatge sag from the result of related simulation works.

The Fundamental Research for Discomfort Glare Evaluation of Building Interior Artificial Illumination (건축실내 인공조명의 불쾌글레어 평가를 위한 기초적 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.27-33
    • /
    • 2006
  • Evaluating comfort of illumination environment of building interior is recognizing the degree of glare causing discomfort. Currently, to use the experimental formula for discomfort glare studied abroad it would be not appropriate because each races feel about the degree of glare differently. Therefore, this study aim to make up prediction formula for evaluating discomfort glare reasonably from Koreans' vision and it proceeded with 4 stages as follows: First, after reviewing the existing discomfort glare evaluation formula, I selected experimental variables. Second, I made a mock-up that I can control experimental variables and conditions according to the purpose of this study. Third, 1 conducted discomfort glare evaluation experiment. Finally, compared with UGR evaluation method suggested for Westerner in prior studies. In conclusion, 1) it's proved that discomfort glare is influenced highly by a light source luminance, background luminance and location of testee and the line of vision. 2) In interior discomfort glare experiment whether the glare light source is placed within range of vision or not has more significant influence than the distance between the light source and testee. 3) I compared and analyzed with UGR, the most representative discomfort glare evaluation system and I found there is a little difference in the results. This shows discomfort glare of Koreans and Westerners are different.

The Development of Portable Digital X-ray Power Supply Unit for Emergency Medical Services (응급의료에서 이용될 휴대용 디지털 X-ray 전원장치 개발)

  • Cho, Dong-Heon;Koo, Kyung-Wan;Yong, Hae-Sool
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.125-131
    • /
    • 2006
  • The existing X-ray generators are either ones which are settled at fixed places or ones which are movable to sick rum. Movable generators can be very useful according to the circumstances of patients, but there remains a restraint that AC220[V] in the hospitals must be provided. When examining a first-aid patient who stays distant from the hospital or when grouping patients caused by disaster, the services of doctors at emergency centers should be very restrictive. Hence, this study developed a portable digital X-ray power supply unit that are utilizable at the accident spot or in a moving ambulance. By using the nit, the information of patients can be transmitted to the emergency center on the spot and thereby doctors can make a correct diagnosis. The properties of the unit are as follows: First, portable batteries(DCl2[V]) are utilized as electric source for the wit. Second PIC16F84A is utilized as control circuit in order to guarantee considerable reliance and to provide various functions. This portable digital X-ray power supply unit is expected to contribute to the emergency medical service system to be more advanced.

Implementation of Evolving Neural Network Controller for Inverted Pendulum System (도립진자 시스템을 위한 진화형 신경회로망 제어기의 실현)

  • 심영진;김태우;최우진;이준탁
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.68-76
    • /
    • 2000
  • The stabilization control of Inverted Pendulum(IP) system is difficult because of its nonlinearity and structural unstability. Futhermore, a series of conventional techniques such as the pole placement and the optimal control based on the local linearizations have narrow stabilizable regions. At the same time, the fine tunings of their gain parameters are also troublesome. Thus, in this paper, an Evolving Neural Network Controller(ENNC) which its structure and its connection weights are optimized simultaneously by Real Variable Elitist Genetic Algorithm(RVEGA) was presented for stabilization of an IP system with nonlinearity. This proposed ENNC was described by a simple genetic chromosome. And the deletion of neuron, the according to the various flag types. Therefore, the connection weights, its structure and the neuron types in the given ENNC can be optimized by the proposed evolution strategy. And the proposed ENNC was implemented successfully on the ADA-2310 data acquisition board and the 80586 microprocessor in order to stabilize the IP system. Through the simulation and experimental results, we showed that the finally acquired optimal ENNC was very useful in the stabilization control of IP system.

  • PDF