• Title/Summary/Keyword: Electrical Fire Hazard

Search Result 43, Processing Time 0.02 seconds

Trends in safety improvement technologies for an electric propulsion system of eco-friendly ships (친환경 선박용 전기추진시스템 안전성 향상 기술개발 동향)

  • Kim, Sehwan;Choi, Gilsu;Lee, Jae Suk
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.556-564
    • /
    • 2021
  • This paper presents trends of safety improvement technologies for an electric propulsion system of eco-friendly ships. As an effort to reduce a green house effect, demands for eco-friendly ships have been increased. An energy storage system (ESS) is one of key systems in an eco-friendly ship and a lithium-ion battery generally used in an ESS system due to its high power density and efficiency. However, a lithium-ion battery is considered as one of reasons for ESS fire hazard. Since a fire extinguishing facility is especially limited in the ocean, safety issue in an eco-friendly ship is important. In this paper, recent safety improvement technologies for traction motors, ESS batteries and structures for eco-friendly ships are presented.

Measurement of the Size Distribution of Smoke Particles with Plastic Types Under Various Fire Conditions (다양한 화재조건에서 플라스틱 종류에 따른 연기입자의 크기분포 변화 측정)

  • Goo, Jaehark;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.8-15
    • /
    • 2017
  • Most fire victims succumb to smoke inhalation, and fire smoke toxicity from interior materials is increasing with increased use of plastics. Large amounts of hazardous effects of smoke are related to deposition of smoke particles in respiratory tracts, and deposition characteristics are influenced by size distribution of particles. Thus, it is essential to know the size distribution of smoke particles from plastics for hazard analysis of fire smoke. In a recent study, it has been shown that size distributions of smoke particles from PP are different from wood in many aspects. In order to know whether other plastics show the same characteristics as PP, size distributions of smoke particles from four plastic materials (LDPE, PA66, PMMA, and PVC) were measured in real time under each fire type with various temperature and oxygen supply. In this study, smoke particles from different plastics were generated uniformly by using steady-state tube furnace method provided in ISO/TS 19700. Their size distributions were measured by using an electrical low pressure impactor (ELPI). Results of measurements showed that size distributions of smoke particles from these four plastic materials were similar to those from PP in many aspects. However, they were distinctively different from those of wood.

A Study on the Ignition Hazards of Flammable Mixtures by Radio Frequency Radiation (고주파 방사에 의한 가연성가스의 점화 위험성 고찰)

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1749-1751
    • /
    • 1998
  • Close to high power radio/radar transmitters there is a possibility that sparks may be occur at discontinuities in metallic structures. If these structures are in an area in which a flammable mixture may be present, there is a possibility that a fire or explosion may be caused by the sparking. A number of assessment procedures for quantification of the hazard have been produced. This paper reviews the bases of the British Standard covering ignition hazards by radio-frequency radiation and presents some ignition test apparatus to access these hazards.

  • PDF

Fault Detection and Classification of Hi9h Impedance Fault using Wavelet Transform (웨이브렛 변환을 이용한 고저항 지락사고 검출 및 판별)

  • Ko, Y.H.;Kim, C.H.;Kim, H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1373-1375
    • /
    • 1999
  • High impedance fault (HIF) is defined as fault the general overcurrent relay can not detect or interrupt. Especially when HIF occur in residential areas, energized high voltage conductor results in fire hazard, equiment damage or personal threat. This paper proposes the model of HIF in transmission line using the ZnO arrester and resistance to be implemented within EMTP. Wavelet transform is efficient and useful for the detection of HIF in power system, because it uses variable windows according to frequency. HIF detection method using wavelet transform can distinguish HIF from similar phenomena like arcfurance load, capacitor bank switching and line switching.

  • PDF

Biomedical Laboratory: Its Safety and Risk Management

  • Tun, Tin
    • Biomedical Science Letters
    • /
    • v.23 no.3
    • /
    • pp.155-160
    • /
    • 2017
  • Biomedical laboratory is full of risks. Risk could be biological, chemical, radioactive, mechanical, physical, fire and electrical. All possible risks need to be identified, evaluated and controlled. A risk management system must be in place to prevent accident or loss of lives and to improve overall workplace safety and productivity. Safety in laboratory is a combination of appropriate risk management system, engineering controls and technical facilities, administrative controls and safety procedures and practices. Laboratory safety culture must be developed so that exposure to hazards for laboratory personnel, community and environment will be minimized or eliminated. In this review, importance of safety in a biomedical laboratory and risk management will be discussed.

The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer (345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발)

  • An, Y.H.;Park, J.B.;Song, T.S.;Han, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

Fire Hazard Analysis of MCCB Terminals in Resistance Load by Connection Failure (저항부하에서 배선용 차단기 접속단자부의 접속결함에 의한 화재위험성 분석)

  • Kim, Dong-Woo;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.88-90
    • /
    • 2007
  • 본 논문에서는 배선용 차단기 단자와 전선간의 접속결함에 의한 아크발생 및 화재위험성을 분석하였다. 실험 및 분석에 사용된 배선용 차단기는 단상 2선식의 국내외 제품으로 외형분석결과 단자구조는 제품마다 상이하였으며, 단자와 전선간의 접촉저항 측정결과 국내 제품은 접속방식에 따라 접촉저항의 편차가 컸다. 배선용 차단기 단자와 전선간 접속결함에 의한 접촉불량 발생시 단자구조에 따른 아크 및 화염의 특성 실험의 부하조건으로는 저항부하를 사용하였으며, 가진기의 축에 배선용차단기를 설치하여 진동에 의한 영향을 받도록 하였다. 인가시간은 10[분]으로 하였으며, 접촉불량이 진전됨에 따라 배선용 차단기 단자에 아크가 지속적으로 발생하였다. 대략 수분이 경과한 후 차단기가 차단되는 경우도 있었으며, 차단되지 않는 경우도 있었다. 또한 4개사의 제품 중 1개사의 제품은 접속단자 주변 절연재료로 아크에 의한 화염전이가 용이하였다.

  • PDF

Simulation of Fault-Arc using EMTP (EMTP를 이용한 아크 사고의 모의)

  • Byun, S.H.;Choi, H.S.;Chae, J.B.;Kim, C.H.;Han, K.N.;Kim, I.D.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.850-852
    • /
    • 1996
  • High impedance fault (HIF) is defined as fault that general overcurrent relay can't detect or interrupt, Especially when HIF occur under 15 kV, energized high voltage conductor results in fire hazard, equipment damage or personal threat. Because most HIF occur arc, HIF detection using arc is to increase. Numerical arc model can be applied in an electromagnetic transients program (EMTP) to reproduce the dynamic and random characteristic of arcs for any insulator arrangement, current and system voltage. It allows the representation of any network configuration to be investigated, so the digital simulation of arc faults through air can be substitute for demanding power arc test.

  • PDF

High Voltage Wiring System Evaluation Methode of FCEV (Fuel Cell Electric Vehicle) (수소연료전지 자동차용 고전압 배선 시스템 평가 기술 개발)

  • Lim, Ji-Seon;Lee, Jeong-Hun;Lee, Hyo-Jeong;Na, Joo-Ran
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.330-336
    • /
    • 2012
  • FCEV uses 250 ~ 450 V instead of using 12 V battery. High voltage vehicle can cause electric shock, fire and explosion accident. Therefore, it has potential factors that can cause hazard of safety for users. United states of America and Europe legislate regulations such as ECE R100, FMVSS 305 for regulating electrical safety during driving or after collision. The company manufacturing high voltage components must do advanced R&D about Method for improving and confirming the safety of high voltage. We develop the specific hardware components of high voltage wiring system for the power train system and power supply system of Hyundai Motors FCEV. This paper shows test method of insulative performance for securing the electrical safety of high voltage components such as power cable, connectors and buss-bar, and proposals the guide line value for human safety of FCEV according to the test result of our development components.

A Risk Assessment in According to Spot Measures and Analysis in Dust Generation Area (분진발생지역의 현장실측과 분석을 통한 위험성 평가)

  • Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.103-110
    • /
    • 2008
  • In terms of electrical safety, environmental impact assessment and revision of domestic regulation are needed for the electric facilities. In this paper, risk of electric facilities is assessed by the spot measures and analysis in dust generation area. Adhesion dust in a surface of insulated materials cause electrical accidents. In a mechanism of these accidents, when the dust lie on electric facilities, a leakage current is flowed and the surface of insulated material is carbonized. Hereafter, electrical fire is generated due to Joule's heat. As the results, dusts are found in protection devices or panel board and sampled dusts vary in sampled amounts and conductivity severally. For the most part, sodium is detected but zinc and calcium are detected in case of reclaimed rubber factory by the ICP-AES(Inductively Coupled Plasma-Atomic Emission Spectroscopy). In a sewerage, the ingredients such as sodium, magnesium, iron, calcium, aluminium, etc are detected uniformly. So that, results of the spot measures and analysis of dusts are become the important data for the assessment of electrical hazard in dust generation area.