• Title/Summary/Keyword: Electrical Door System

Search Result 75, Processing Time 0.029 seconds

Development of High Reliability Monitoring and Control System for Platform Screen Door (승강장 스크린 도어(PSD)에 대한 고 신뢰성의 감시 및 제어 시스템 개발)

  • Kim, Jin-Sik;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.158-162
    • /
    • 2010
  • PSD is automatically opened and closed when subway train arrive on the station. This system was designed to control electric automatic system. These doors will provide passenger safety, energy saving and a good environment in subway. The monitoring and control systems of PSD are configured so that they can be operated in automatic mode in connection with ATO through the composite control panel in the station control room. The objective of this paper is to obtain high reliability that is essential for monitoring and control systems of PSD. The power supply is based on protection circuit using DC power bridge from two UPS. Also, stable communication system consists of CAN communication line redundancy and RF cross protection algorithm. Monitoring state display results show the validity of the proposed high reliability monitoring and control systems of PSD.

Reliable Digital Door Lock Control System using Face Recognition (얼굴 인식을 통한 신뢰성 있는 디지털 도어록 제어 시스템)

  • Lim, Jimin;Kim, Chan;Cha, Wonsuk;Han, Taemoon;Huh, Guewon;Song, Sanggeun;Lee, Sangjun
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.499-504
    • /
    • 2013
  • Automation is being progressed rapidly in various fields with the advancement of IT technology. Home automation is a typical application and is being used in a variety of ways now. Most of digital door lock systems simply support to open and close a door using the methods of password and a particular magnetic key. In this paper, we propose a intelligent digital door lock system using face recognition technology. Our proposed system can control the locking device opening and closing from a remote location after confirming the identification of the visitor via a smart device, and support the reliable and secure control of door systems.

IoT Open-Source and AI based Automatic Door Lock Access Control Solution

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Mariappan, Vinayagam;Young, Ko Eun;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.8-14
    • /
    • 2020
  • Recently, there was an increasing demand for an integrated access control system which is capable of user recognition, door control, and facility operations control for smart buildings automation. The market available door lock access control solutions need to be improved from the current level security of door locks operations where security is compromised when a password or digital keys are exposed to the strangers. At present, the access control system solution providers focusing on developing an automatic access control system using (RF) based technologies like bluetooth, WiFi, etc. All the existing automatic door access control technologies required an additional hardware interface and always vulnerable security threads. This paper proposes the user identification and authentication solution for automatic door lock control operations using camera based visible light communication (VLC) technology. This proposed approach use the cameras installed in building facility, user smart devices and IoT open source controller based LED light sensors installed in buildings infrastructure. The building facility installed IoT LED light sensors transmit the authorized user and facility information color grid code and the smart device camera decode the user informations and verify with stored user information then indicate the authentication status to the user and send authentication acknowledgement to facility door lock integrated camera to control the door lock operations. The camera based VLC receiver uses the artificial intelligence (AI) methods to decode VLC data to improve the VLC performance. This paper implements the testbed model using IoT open-source based LED light sensor with CCTV camera and user smartphone devices. The experiment results are verified with custom made convolutional neural network (CNN) based AI techniques for VLC deciding method on smart devices and PC based CCTV monitoring solutions. The archived experiment results confirm that proposed door access control solution is effective and robust for automatic door access control.

Real-time Streaming and Remote Control for the Smart Door-Lock System based on Internet of Things (스마트 도어록 시스템을 위한 IoT 기반의 실시간 스트리밍 및 원격 제어)

  • Lee, Sung-Won;Yu, Je-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.6
    • /
    • pp.565-570
    • /
    • 2015
  • In this paper, we implemented the smart door lock system that control remotely devices using the concept of internet of things. Internet of things is intelligent system that can help devices to communicate with people and devices. And recently internet of things is getting attention because of advance of hardware technology and big data. The smart doorlock system based on internet of things used raspberry pi, sensor and doorlock. Using the smart phone, doorlock can be controlled from the raspberry pi server. And the user can identify some people that is in front of doorlock. also user can check around of doorlock in realtime using the raspberry pi camera.

Allocation of Safety Integrity Level for Railway Platform Screen Door System considering Semi-Quantitative Risk Reduction Factor (반 정량적 리스크 저감 요소를 고려한 철도 승강장 스크린 도어시스템의 안전 무결성 수준 할당)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.156-163
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, the theoretical and practical study for safety integrity level is barely under way in the domestic railway industry. This research studied not only the global process of SIL allocation to guarantee safety in accordance with international standards for safety related equipment and system, but the quantitative methodology based on international standard and the semi-quantitative methodology as alternative way for SIL allocation. Specifically, the systematic SIL allocation for platform screen door system of railway is studied applying the semi-quantitative methodology in order to save much time and effort compared to quantitative method.

Allocation of Safety Integrity Level for Railway Platform Screen Door System based on Consequence Severity and Risk Graph (결과 심각도 및 리스크 그래프에 기반한 철도 승강장 도어시스템의 안전 무결성 수준 할당)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.164-173
    • /
    • 2015
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, application standard differs from every industry in domestic or international for application on mythology for allocation and demonstration of SIL. Application or assessment is not easy since absence on clear criteria or common definition. This research studied not only fundamental concept of SIL required to guarantee safety in accordance with international standards for safety related equipment and system, but different types of methodologies for SIL allocation. Specifically, SIL allocation for Platform Screen Door system of railway is studied applying methodology of severity of accidents and risk graph among different methodologies for SIL allocation.

Operating Characteristics of Actuator System for Automatic Door Operated by Temperature Detecting Sensor (온도 감지 센서가 구비된 도어 자동 개폐기 구동용 액추에이터 시스템의 동작 특성 해석)

  • Kim Y. H.;Son W. T.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.815-817
    • /
    • 2004
  • This paper deals with the characteristics analysis and experiments of operating actuator for automatic door operated by fire detecting sensor. The dynamic characteristics of operating actuator system are analyzed on the structure of the operating actuator model. Simulation and experimental result have been performed for the verification of the proposed system and dynamic characteristics applied to a actuator by electromechanical energy conversion theory. The experimental result have been compared with proposed theoretical predictions. In this experimental result represented the temperature T1 and T2 which remarks T1 is a circumstance of operating actuator system, and T2 is a fire detecting sensor part.

  • PDF

A Study Of Developing Control Network based Fingerprint Recognition Door Controller (제어 네트워크 기반의 지문인식 도어 컨트롤러 개발에 관한 연구)

  • Yang, Jae-Won;Park, Jin-Seok;Yoon, Seok-Hyun;Shim, Il-Joo;Park, Gwi-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.313-316
    • /
    • 2002
  • The need to protect a main information and control a personal access using Biometrics in the intelligent building system is extended with growing the information and communication technologies in recent years. The fingerprint recognition technology is one of the biometrics methods available that has been widely used in various applications. But the present architecture of fingerprint recognition system has many of the problems because of centralized control network architecture. But we can solve the problems with distributed control network architecture. In this paper, the fingerprint recognition system uses the merit of the LonWorks. it is able to easily modularize the system and make up for the weak points in the typical fingerprint recognition system.

  • PDF

Study of Electrical and Mechanical Characteristic of Support Insulator for Out Door Sealing End Using Extra High Voltage Power Cable System (초고압 전력케이블 시스템의 Out Door Sealing End용 Support Insulator의 재질에 따른 전기적 기계적 특성에 관한 연구)

  • Ryu, Jeong-Hyun;Kim, Woo-Jin;Kim, Young-Bum;Han, Bong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1412_1413
    • /
    • 2009
  • 초고압 전력케이블용 기중 종단접속재에 사용되는 지지애자의 전기적 고절연 성능과 기계적 Compact화된 제품개발을 목적으로 Simulation Tool을 활용하여 전계해석을 수행하였고, 해석된 결과를 기초로 지지애자를 설계, 개발 하였다. 개발된 지지애자의 Sample을 채취하고 전기적, 기계적 시험을 통하여 신뢰성을 검증 하였다. 전계해석에 있어서는 Epoxy와 Porcelain 재료, Old type과 New type으로 구분하여 재료별, 구조별로 해석을 진행 하였다. 지지애자의 설계기준과 전기적, 기계적 시험 결과를 비교하여 개발된 제품의 특성에 있어서 얼마만큼의 안전율을 확보 할 수 있는지 알 수 있었고, Porcelain 지지애자와 비교하여 약 40%의 크기를 축소할 수 있는 전기적, 기계적 신뢰성이 확보된 지지애자를 개발 할 수 있었다.

  • PDF

Design and Implementation of a Sensor Node for Out-Door Environmental Monitoring (옥외 환경 모니터링을 위한 센서노드 설계 및 구현)

  • Son, Jae-Hyun;Cho, Yang-Haeng;Kim, Je-Hong;Joo, Young-Suk;So, Sun-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.117-122
    • /
    • 2007
  • In this paper, we described a design and implementation of a sensor node for environmental monitoring. The main focus of design for sensor nodes is to isolate MCU for treating sensors from the RF module for considering various communication environment. The second is to make the interface between MCU and varity of sensor. In addition, we choose a narrow band communication module, cc1020, for the admittance of Korea government communication law. We also use a uC/OS-II as an operating system which is famous for 8bit MCUs. We showed that the communication performance is sufficient to use the communication module in a out-door environment through several experiments in that it is possible to transmit between 100m distance through experiments in a mountain.