• 제목/요약/키워드: Electrical Control

검색결과 19,215건 처리시간 0.04초

An Improvement on Robust $H{\infty}$ Control for Uncertain Continuous-Time Descriptor Systems

  • Lee Hung-Jen;Kau Shih-Wei;Liu Yung-Sheng;Fang Chun-Hsiung;Chen Jian-Liung;Tsai Ming-Hung;Lee Li
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권3호
    • /
    • pp.271-280
    • /
    • 2006
  • This paper proposes a new approach to solve robust $H{\infty}$ control problems for uncertain continuous-time descriptor systems. Necessary and sufficient conditions for robust $H{\infty}$ control analysis and design are derived and expressed in terms of a set of LMIs. In the proposed approach, the uncertainties are allowed to appear in all system matrices. Furthermore, a couple of assumptions that are required in earlier design methods are not needed anymore in the present one. The derived conditions also include several interesting results existing in the literature as special cases.

개선된 De-loading기법을 이용한 해상풍력 연계용 HVDC의 DC 전압의 제어방안 (DC-link Voltage Control of HVDC for Offshore Wind Farm using Improved De-loading Method)

  • 허재선;문원식;박상인;김두희;김재철
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.399-404
    • /
    • 2015
  • This paper presents the DC voltage control method in DC link of High Voltage Direct Current(HVDC) for an offshore wind farm in Low Voltage Ride Through(LVRT) situation. Wind generators in an offshore wind farm are connected to onshore network via HVDC transmission. Due to LVRT control of grid side inverter in HVDC, power imbalancing in DC link is generated and this consequentially causes rising of DC voltage. A de-loading scheme is one of the method to protect the wind power system DC link capacitors from over voltage. But the flaw of this method is slow control response time and that it needs long recovery time to pre-fault condition after fault clear. Thus, this paper proposes improved de-loading method and we analyze control performance for DC voltage in LVRT control of HVDC for an offshore wind farm.

엔진발전기와 연계된 BESS의 무순단 모드 전환 기법 (Seamless Transfer Method of BESS Connected by Engine Generator)

  • 신은석;김현준;김교민;유승영;한병문
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1709-1717
    • /
    • 2015
  • In remote islands PV (Photo Voltaic) panel with BESS (Battery Energy Storage System) supplies electric power to the customers in parallel operation with EG (Engine Generator) to save fuel consumption and to mitigate environmental load. BESS operates in voltage control mode when it supplies power to the load alone, while it operates in current control mode when it supplies power to the load in parallel with EG. This paper proposes a smooth mode change scheme from current control to voltage control of BESS by adding proper initial value to the integral part of voltage control, and a smooth mode change scheme from voltage control to current control by tracking the EG output voltage to the BESS output voltage using PLL (Phase-Locked Loop). The feasibility of proposed schemes was verified through computer simulations with PSCAD/EMTDC, and the feasibility of actual hardware system was verified by experiments with scaled prototype. It was confirmed that the proposed schemes offer a seamless operation in the stand-alone power system in remote islands.

A Novel Control Algorithm of a Three-phase Four-wire PV Inverter with Imbalance Load Compensation Function

  • Le, Dinh-Vuong;Kim, Chang-Soon;Go, Byeong-Soo;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1131-1137
    • /
    • 2018
  • In this paper, the authors suggest a new control algorithm for a three-phase four-wire photovoltaic (PV) inverter with imbalance load compensation function using conventional proportional-integral (PI) controllers. The maximum power of PV panel is calculated by the MPPT control loop. The reference varying signals of current controllers are transformed to two different rotating frames where they become constant signals. Then simple PI controllers are applied to achieve zero steady-state error of the controllers. The proposed control algorithm are modeled and simulated with imbalance load configuration to verify its performance. The simulation results show that the maximum PV power is transferred to the grid and the imbalance power is compensated successfully by the proposed control algorithm. The inverter has a fast response (~4 cycles) during the transient period. The proposed control algorithm can be effectively utilized to the three-phase four-wire inverter with imbalance load compensation function.

Sliding Mode Control Based DTC of Sensorless Parallel-Connected Two Five-Phase PMSM Drive System

  • Kamel, Tounsi;Abdelkader, Djahbar;Said, Barkat;Al-Hitmi, M.;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1185-1201
    • /
    • 2018
  • This paper presents a sensorless direct torque control (DTC) combined with sliding mode approach (SM) and space vector modulation (SVM) to achieve mainly a high performance and reduce torque and flux ripples of a parallel-connected two five-phase permanent magnet synchronous machine (PMSM) drive system. In order to increase the proposed drive robustness and decrease its complexity and cost, the rotor speeds, rotor positions, fluxes as well as torques are estimated by using a sliding mode observer (SMO) scheme. The effectiveness of the proposed sliding mode observer in conjunction with the sliding mode control based DTC is confirmed through the application of different load torques for wide speed range operation. Comparison between sliding mode control and proportional integral (PI) control based DTC of the proposed two-motor drive is provided. The obtained speeds, torques and fluxes responses follow their references; even in low and reverse speed operations, load torques changes, and machines parameters variations. Simulation results confirm also that, the ripples of the torques and fluxes are reduced more than 3.33% and 16.66 %, respectively, and the speed overshoots and speed drops are reduced about 99.85% and 92.24%, respectively.

구조 목적에 적용 가능한 보행가능 드론에 대한 연구 (A Study on Walking Dron available for a rescue Purpose)

  • 전진성;이지빈;백종환;봉대근;이지현;박명숙;김상훈
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 추계학술발표대회
    • /
    • pp.1772-1775
    • /
    • 2015
  • 본 논문에서는 쿼드콥터와 4족이동 로봇을 결합 하여 임베디드 보드를 이용한 실시간 영상처리를 활용하고 환경 탐지용 센서를 부착하여 재난극복 및 재난현장에서의 인명구조, 신원확인을 하는 지능로봇을 제안한다. 쿼드콥터는 비행이동을 하면서 임무를 수행하고 4족이동 로봇은 지상 임무수행을 하는 로봇이다. 본 논문에서는 쿼드콥터와 4족 이동로봇의 결합으로 인해 로봇의 무게 고려를 하여 설계를 하여, 비행과 지상을 이동하며 영상처리를 이용하여 임무를 수행 할 수 있는 로봇을 제작 했다.

물리적 요인 분석을 통한 벽면 이동 로봇의 성능 개선 연구 (A Study on the Performance Improvement of Wall Climbing Robot using Physical Variable Analysis)

  • 이지빈;정명수;전진성;백종환;봉대근;이지현;김상훈
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 춘계학술발표대회
    • /
    • pp.1071-1074
    • /
    • 2015
  • 본 논문은 진공을 이용한 흡착방식과 바퀴형 이동방식을 이용하고 환경 탐지용 센서를 부착한 벽면 이동형 로봇의 물리적 해석을 통한 이동 성능 개선에 관한 연구로서, 대형 구조물의 안전 검사 및 위험한 시설물의 보수 작업등을 보조하기 위한 목적이 있다. 로봇의 무게에 따른 중력을 견딜 수 있는 강력한 진공흡착방식과 고성능 모터 제어에 의한 바퀴 이동방식을 혼합하고 효율적으로 평형을 유지 또는 제어하기 위하여 로봇에 미치는 다양한 힘과 모멘트를 분석하고 수식화 하였으며 기존의 수직이동 속도를 개선하기 위한 로봇의 물리적 변수를 추출하여 변수와 이동력간의 관계를 고찰하였다.

Active Disturbance Rejection Control for Single-Phase PWM Rectifier with Current Decoupling Control

  • Yan, Ruitao;Wang, Ping
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2354-2363
    • /
    • 2018
  • This paper proposed a novel double closed control strategy for single-phase voltage source pulse width modulation (PWM) rectifier based on active disturbance rejection control (ADRC) and dq current decoupling control. First, the mathematical model of the single-phase PWM rectifier in the d-q axis synchronous rotating reference frame is established by constructing a virtual component using a second-order generalized integrator (SOGI). Then, the mathematical model is simplified according to the active power conservation, and the first-order equation of single-phase PWM rectifier voltage outer loop is acquired. A linear auto-disturbance rejection controller is used to design the voltage outer loop according to the first-order equation. Finally, the proposed control strategy and the traditional PI control are compared and verified by simulation and physical experiments. Both simulation and experimental results confirm that the proposed control strategy has excellent dynamic performance and strong rejection ability to disturbances.

외란 관측기를 이용한 모형 자율 주행 자동차의 강인 속도 제어 (Robust Speed Control of an Autonomous Vehicle Using Disturbance Observer)

  • 고영준;김영준;김정수
    • 제어로봇시스템학회논문지
    • /
    • 제22권5호
    • /
    • pp.339-345
    • /
    • 2016
  • This paper presents a robust speed control of an autonomous vehicle using a disturbance observer. For the purpose, the transfer function of speed dynamics of an autonomous vehicle is identified using step response data. Based on the identified transfer function, model based PID (Proportional-Integral-Derivative) control is designed. In order to design a robust control against load variations on the vehicle, a disturbance observer (DOB) based control is devised. The performance of the designed DOB based control is demonstrated by real experiments.

Tracking Control Method of a Step Motor for a Bilateral Symmetric Trainer

  • Kim, Young-Tae
    • 조명전기설비학회논문지
    • /
    • 제23권11호
    • /
    • pp.94-101
    • /
    • 2009
  • This paper poses tracking control and torque control methods to reduce torque ripple for bilateral symmetric trainers. As opposed to the conventional method, the torque control method for active joint movement is proposed. Using a step motor (PK296-03b, step angle: $1.8^{\circ}$), a simulator for a bilateral symmetric trainer is created, and the effectiveness of the proposed control method is verified through experiment results.