• 제목/요약/키워드: Electrical Connector

검색결과 105건 처리시간 0.027초

CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구 (A study on the Grounding method for reduce an interference by CATV Transmission Line)

  • 황종선;연제진;박성진;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구 (A study on the Grounding method for reduce an interference by CATV Transmission Line)

  • 황종선;연제진;박성진;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

전차선로 전기적 특성 평가 시스템 구현 (Implementation of Electrical Property Assessment System for Overhead Contact Lines)

  • 오석용;박영;조용현;이기원;송준태
    • 한국전기전자재료학회논문지
    • /
    • 제24권6호
    • /
    • pp.497-503
    • /
    • 2011
  • Currently in Korea, the simple catenary type overhead contact line system is being applied to both conventional lines and high speed lines of electric railway, and circulation current flowing into the catenary system frequently bring undesirable consequences. Namely, the connector wire has many problems according to a flow of excessive circulation current and arc current on catenary when an electric train runs at high speed. This paper presents the development and application of a real-time data acquisition system designed to measure the electrical characteristics of an overhead catenary system in electric railways. The developed system is capable of storing data of a 25 kV power source in a live wire state through a telemetry environment. The field test results show that the proposed technique and the developed system can be practically applied to measure characteristics of current of an overhead catenary system.

매설지선 방식을 적용한 에너지 자립마을용 수상 태양광 발전 시스템의 접지저항 분석 (Analysis of Grounding Resistance for Zero Energy Town Floating PV System Using Underground Wiring)

  • 고재우;임종록;;차혜림;김시한;이창구;안형근
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.303-306
    • /
    • 2016
  • Floating PV system is installed on the water such as artificial lake, reservoir, river for the purposes of zero energy town and/or large scale of PV station. There are electrical gains from cooling effect by water and reflection of water surface. Particularly, floating PV power station with high efficiency solar cell modules receives a lot of attention recently. Floating PV system is installed on the water, which means grounding method to the frame of solar cell and electrical box such as connector band and distribution panelboard should be applied in different way from grounding method of PV system on land. The grounding resistance should be 10[${\Omega}$] in case the voltage is over 400[V] in accordance with Korean Standard. The applicable parameters are the resistivity of water in various circumstances, depth of water, and length of electrode in order to meet 10[${\Omega}$] of grounding resistance. We calculated appropriate length of the electrode on the basis of theoretical equation of grounding resistance and analyzed the relation between each parameters through MATLAB simulation. This paper explains grounding system of floating PV power station and presents considerations on grounding design according to the resistivity of water.

반도체 공정 칠러 장비의 히터 접속부 전기배선에 대한 열적 특성 분석 (Analysis of Thermal Characteristic for Wiring at Heater Connector of Semiconductor Chiller Equipment)

  • 김규빈;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.27-34
    • /
    • 2023
  • With the technological development of the semiconductor industry, the roles of electrical and thermal energy supply and control of semiconductor equipment in ultrafine processes have become very important. However, instances of electrical fires in the chiller heater, which is used for cooling in the semiconductor manufacturing process, are increasing. A fire occurs in combustibles due to high heat at the connection part of the chiller heater, that is, when the number of electrical wires in the connection part is reduced or when the wires are completely disconnected. In this study, the temperature characteristics were compared and analyzed through experiments and 3D simulations. The number of electrical wires, which is the connection part of the chiller heater, was reduced by 90%, 50%, 30%, 10%, and 5%, and the wires were completely disconnected. When the number of electrical wires was reduced by 5%, heat of up to 80℃ was generated, which is a relatively high temperature but insufficient to cause a fire in combustibles. Complete disconnection occurred due to the vibration of the motor and other components, and sparks and arcs were generated, resulting in a rapid increase in temperature to up to 680℃. When completely disconnected, the temperature increase was sufficient to cause a fire in the combustibles covering the terminal block. Therefore, in this study, the causes of electrical fires in chiller heaters were investigated and preventive measures were proposed by analyzing abnormal signals and thermal characteristics caused by the electrical wiring being reduced and completely disconnected.

심해 압력용기 덮개판의 수중 커넥터홀 배치 최적설계 (Optimum Design of Underwater Connector Hole Arrangement for Deep-sea Pressure Vessel Cover Plate)

  • 이민욱;박성재;여태경;김형우;홍섭;조수길;장준용;이태희;최종수
    • 대한기계학회논문집A
    • /
    • 제36권12호
    • /
    • pp.1627-1633
    • /
    • 2012
  • 심해저 장비에 사용되는 압력용기는 내장된 전자장비를 대기압 상태로 보호할 수 있도록 설계되어야 한다. 따라서 해수에 노출되지 않도록 수밀성과 심해의 높은 압력을 견딜 수 있는 구조적 안전성을 확보해야 한다. 본 연구의 압력용기는 원통형이며, 중앙부의 원통형 용기와 양 끝단의 평판형 덮개부로 이루어져있다. 일반적으로 압력용기 내부 전자장비와의 통신 및 전력전송을 위해 압력용기 덮개판에 다양한 수중 커넥터를 배치 한다. 그러나 한정된 덮개판 공간에 다수의 홀이 배치되면 응력집중을 유발하여 압력용기 덮개판의 구조적 안전성에 영향을 줄 수 있다. 본 논문에서는 구조적 안전성을 고려한 압력용기 덮개판의 홀 배치 최적화 기법에 대한 연구를 수행하였다.

지지애자의 표면오염 모니터링 기술 및 장치 (Monitoring Technique and Device of Surface Contamination for Line-Post Insulator)

  • 길경석;박대원;정광석;김선재;서동환
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.413-417
    • /
    • 2010
  • Line to ground faults by deterioration of insulators has frequently occurred in power system, and the main cause is surface contamination of the insulators. The contamination of insulator is analyzed by monitoring the surface leakage current flowing them. The suspension insulator is monitored by installation of a zero-phase current sensor(ZCT), but the line-post insulator is impossible to apply the same method because of its large diameter structure. This paper proposed a detection method of surface leakage current for a line-post insulator, and it can easily be applied to new and/or built insulators. The leakage current is indirectly calculated from the potential difference between the metal electrode attached on the surface of insulator and the ground connector. To evaluate the performance of the proposed method, the leakage current is compared as a function of contamination condition controlled by the density of NaCl solution. The leakage current is proportioned to the density of NaCl solution, and the voltage detected by the electrode showed the same trend. From the experimental results, we designed and fabricated a monitoring device which is composed of a detection electrode, signal converter, microprocessor, and ZigBee, and its measurement range is $10{\mu}A{\sim}5mA$.

활선상의 부분방전 측정 방법 (On-line Measurement of Partial Discharge)

  • 백광현;최용성;박대희;이창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1936-1938
    • /
    • 2004
  • In this paper, we discussed measurement method of PD (Partial Discharge) of 22.9[kV] cable. Cable rail track laying portable detector that can detect partial discharge of cable connection ashes by on-line done spot way to detect Lemke equipment and high broadcasting CT sensor that use antenna sensor using ICM mounting was explained. Because measurement corona signal is very big, analysis of partial discharge is difficult state, we used connector. It could be attenuated by 2 times. We found out that corona signal which generated on B phase is flowed on A phase and C phase. It could measure that partial discharge of A phase happens actually. We could confirm that partial discharge of about 250 ${\sim}$ 300 [pC] on A phase is dangerous.

  • PDF

사건수목분석을 통한 수배전설비의 전기화재위험성 분석 (Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis)

  • 박영호;김두현;김성철
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

편중 시공된 직선 슬리브의 장력 및 열적 특성 분석 연구 (The Study on Tension and Thermal Properties of Baised Installed Sleeve)

  • 안상현;김병걸;김상수;손홍관;박인표;김성규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1209-1210
    • /
    • 2008
  • According to previous report, aged sleeves for old transmission lines have variable defects such as biased installed case or corrosion of steel sleeve. Biased installed sleeve occupied 20 percent among the investigated aged sleeves. This defect must cause local heating of splice connector and limit power transmission capacity. It even inspire falling out of overhead conductor from sleeves. This paper studies thermal properties and tension for ACSR conductor in case of biased installed sleeve model. The detailed results were presented in the text.

  • PDF