• Title/Summary/Keyword: Electrical Conductivity (EC)

Search Result 385, Processing Time 0.031 seconds

Son Conduction Properties of PVDF/PAN based for Lithium Polymer Battery (리튬 폴리머전지용 PVDF/PAN계 전해질의 이온 전도 특성)

  • 이재안;김종욱;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.374-377
    • /
    • 1999
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. This paper describes temperature dependence of conductivity, impedance spectroscopy, electrochemical properties of PVDF/PAN electrolytes as a function of a mixed ratio. PVDF/PAN based polymer electrolyte films were prepared by thermal gellification method of preweighed PVDF/PAN, plasticizer and Li salt. The conductivity of PVDF/PAN electrolytes was 10-3S/cm. 20PVDF5PANLiCIO$_4$PC$\sub$10//EC$\sub$10/ electrolyte shows the better conductivity of the others. 20P7DF5PANLiCI$_4$PC$\sub$10//EC$\sub$10/ electrolyte remains stable up to 5V vs. Li/Li$\^$+/. Steady state current method and ac impedance used for the determination of transference numbers in PVDF/PAN electrolyte film. The transference number of 20PVDF5ANLICIO$_4$/PC $\sub$10//EC$\sub$10/ electrolyte is 0.48

  • PDF

EC or TDS as a Water Pollution Criteria in Water Education Program (물환경 체험 및 탐구 활동에서 수질오염지표로서 전기전도도(EC) 혹은 총용존고형물질(TDS)의 활용에 대한 고찰)

  • Ahn, Samyoung
    • Journal of Environmental Science International
    • /
    • v.31 no.4
    • /
    • pp.341-356
    • /
    • 2022
  • Electrical Conductivity (EC) or Total Dissolved Solids (TDS) has been often used to evaluate the water quality in some water education program for children and youth. This study attempted to find out whether EC (or TDS) can be used as a water pollution criteria in water education program. To clarify it, we used the water analysis data of July 2019 and January 2020 from Water Environment Information System. Data from 332 points in Han-river were used to investigate correlation between the parameters, such as BOD, COD, TN, TP vs EC. Correlation(r) for all data of BOD vs. EC was 0.347 for July 2019 and 0.483 for January 2020. No correlation was observed for BOD Ia and BOD Ib for July 2019 (r=-0.041, -0.030, respectively) and BOD Ia for January 2020 (r=0.041). Better correlation for all data of COD vs. EC was obtained (r=0.543 for July 2019 and r=0.610 for January 2020). However, no correlation was observed for COD Ia for January 2020. High vlaue of EC or TDS does not always mean water pollution, especially for clean water environment. Thus, EC (or TDS) alone can not be used as a water pollution criteria.

Conductivity of PAN/PVDF based Polymer Electrolyte as a Function of Plasticizer Mixed Ratio (가소제 혼합비에 따른 PAN/PVDF계 고분자 전해질의 이온 전도 특성)

  • Lee, Jae-An;Kim, Jong-Uk;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.261-264
    • /
    • 2000
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. This paper describes temperature dependence of conductivity, impedance spectroscopy, electrochemical properties of PAN/PVDF electrolytes as a function of a mixed ratio. PAN/PVDF based polymer electrolyte films were prepared by thermal gellification method of preweighed PAN/PVDF, plasticizer and Li salt. By adding PVDF and as a function of plasticizer mixed ratio to PAN-LiClO4 electrolyte, its conductivity was higher than that of PAN-$LiClO4_4$ electrolyte. The conductivity of PAN/PVDF electrolytes was $10^{-3}S/cm$. $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte shows the better conductivity of the others. Steady state current method and ac impedance used for the determination of transference numbers in PAN/PVDF electrolyte film. The transference number of $10PAN10PVDFLiClO_4PC_5EC_5$ electrolyte is 0.45.

  • PDF

Discussion on Dilution Factor for Electrical Conductivity Measured by Saturation-paste Extract and 1:5 Soil to Water Extract, and CEC of Korean Soils (한국 토양에 대한 포화침출액법과 1:5 법에 의한 전기전도도 간의 희석배수와 CEC의 관계에 대한 고찰)

  • Jung, Yeong-Sang;Joo, Jin-Ho;Hong, Sun-Dal;Lee, In-Bog;Ro, Hee-Myong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.1
    • /
    • pp.71-75
    • /
    • 2001
  • Linear regression analyses between the electrical conductivity of the saturation-paste extract. ECe, and the electrical conductivity of the 1:5 soil extract, EC1:5, for different soils yielded different dilution factors, or slopes with significant $r^2$ values from 0.842 to 0.905. The dilution factor was inversely proportional to the cation exchange capacity of soil which reflected textural difference. The dilution factors recommended for different textural classes ranged from 6.44 for clay soil to 12.29 for sandy soil based on the CEC's of the textural classes among 350 surface soils recorded in the Taxonomical Classification of Korean Soils except volcanic ash derived soils. Though saturation percentage of the saturation-paste of the soils in this study, CEC should be taken into account for dilution factor between ECe and EC1:5, and the suggested dilution factors might be reasonable estimate for the soil textural classes.

  • PDF

Analysis of Electrical Conductivity during the Growing Period in Saemangum Recaliamed Tidal Lands (새만금 간척지토양의 벼생육과정중 전기전도도 분석)

  • Son, Jae-Gwon;Choi, Jin-Kyu;Koo, Ja-Woong;Song, Jae-Do;Kim, Young-Joo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.79-82
    • /
    • 2003
  • This study was performed in order to analyze the changes of electrical conductivity during the growing period in Saemangum reclaimed tidal lands soils. According to USDA Salinity Laboratory classification system of salt affected soils, the reclaimed tidal land soils used in this study were saline-sodic soils. As the results obtained from analying the changes of electrical conductivity(EC) during the growing period in reclaimed tidal land soils, EC of irrigation water and soils were no difference among the fertilization quanity, fertilization method and fertilization times.

  • PDF

Effects of Electrical Conductivity on the Soil Microbial Community in a Controled Horticultural Land for Strawberry Cultivation (시설딸기재배지 토양에서 염류농도가 미생물 생태에 미치는 영향)

  • Lee, Young-Han;Ahn, Byung-Koo;Sonn, Yeon-Kyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.830-835
    • /
    • 2011
  • Total soil microbial activities have great impact to soil management for organic farming. This study was evaluated in the soil microbial community by fatty acid methyl ester (FAME) in a controlled horticultural field for strawberry organic farm. Experimental plots were prepared with a high level of soil electrical conductivity (EC) and a optimum level of soil EC. Soil microbial biomasses and communities of total bacteria, Gram-negative bacteria, Gram-positive bacteria, actinomycetes, fungi, and arbuscular mycorrhizal fungi in the high level of soil EC were significantly larger than those in the optimum level of soil EC. Lower ratios of cy17:0 to 16:$1{\omega}7c$ and cy19:0 to 18:$1{\omega}7c$ were found in the optimum level of soil EC than those in the high level of soil EC, indicating that microbial stress decreased.

Ion Conduction Properties of PVDF/PAN based Polymer Electrolyte for Lithium Polymer Battery (리튬 폴리머전지용 PVDF/PAN계 고분자 전해질의 이온 전도 특성)

  • 이재안;김종욱;구할본
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.306-311
    • /
    • 2000
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li polymer battery. The temperature dependence of conductivity impedance spectroscopy and electrochemical properties of PDF/PAN electrolytes as a function of a mixed ratio were reported for PVDF/PAN based polymer electrolyte films which were prepared by thermal gellification method of preweighed PVDF/PAN plasticizer and Li salt. The conductivity of PVDF/PAN electrolytes was 10$\^$-3/S/cm. 20PVDF5PEN LiCiO$\_$4//PC$\_$10//EC$\_$10/ electrolyte has the better conductivity compared to others. 20PVDF5PANLICIO$\_$4//PC$\_$10//EC$\_$10/ electroylte remains stable up to 5V vs. Li/Li$\^$+/. Steady state current method and ac impedance were used for the determination of transference numbers in PVDF/PAN electrolyte film. The transference number of 20PVDF5PANLiCO$\^$4//PC$\_$10//EC$\_$10/ electrolyte is 0.48.

  • PDF

Determination of Refreshing Time of Natural Zeolite Used for Livestock Waste Water Clearing Based on Electrical Conductivity (축산폐수(畜産廢水) 처리시(處理時) 전기전도도(電氣傳導度)를 기준(基準)한 천연(天然) Zeolite의 교환시기(交換時期) 결정(決定))

  • Choi, Jyung;Seo, Young-Jin;Lee, Dong-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.2
    • /
    • pp.130-136
    • /
    • 1996
  • This study was carried out easily to determine the refreshing time of natural Zeolite used for the clearing of Livestock waste water and to investigate the relationship between EC of solution and adsorption amount on Zeolite. During the adsorption reaction, EC of supernatant solution decreased till the equilibrium was reached and kept a constant level after it. EC was greatly decreased with the concentration of solution and the magnitude of adsorbent. Decrease in EC of suspension was found to be lesser in addition of Na-Zeolite than Ca-Zeolite. EC change of Livestock waste water was shown to be similar tendency to that of the simulated waste water. On the cumulative adsorption isotherm, the EC of suspension increased until the EC value of the initial solution as the increase in treatment times. Therefore, it is apparent that the exchange point of natural zeolite should be in the vicinity of the EC value of initial waste water.

  • PDF

Assessment of Electrical Conductivity of Saturated Soil Paste from 1:5 Soil-Water Extracts for Reclaimed Tideland Soils in South-Western Coastal Area of Korea

  • Park, Hyun-Jin;Yang, Hye In;Park, Se-In;Seo, Bo-Seong;Lee, Dong-Hwan;Kim, Han-Yong;Choi, Woo-Jung
    • Korean Journal of Environmental Agriculture
    • /
    • v.38 no.2
    • /
    • pp.69-75
    • /
    • 2019
  • BACKGROUND: Measurement of electrical conductivity of saturated soil paste ($EC_e$) for assessment of soil salinity is time-consuming, and thus conversion of EC of 1:5 soil-water extract ($EC_{1:5}$) to $EC_e$ using a dilution factor may be of help to monitor salinity of huge number of soil samples. This study was conducted to evaluate the dilution factor for reclaimed tideland (RTL) soils of South Korea. METHODS AND RESULTS: Soil samples (n=40) were collected from four RTLs, and analyzed for $EC_{1:5}$, $EC_e$, and cation compositions of 1:5 soil-water extract. The dilution factor (8.70) was estimated by regression analysis between $EC_{1:5}$ and $EC_e$, and the obtained dilution factor was validated by applying to an independent data set (n=96) of $EC_{1:5}$ and $EC_e$. The $EC_e$ measured and predicted was strongly correlated ($r^2=0.74$, P<0.001), but $EC_e$ was overestimated by 16% particularly for the soils with high clay content and low sodium adsorption ratio (SAR). CONCLUSION: This study suggests that using the dilution factor to convert $EC_{1:5}$ to $EC_e$ is feasible method to monitor changes in the soil salinity of the study RTL. However, overestimation of $EC_e$ should be cautioned for the soils with high clay content and low SAR.

Analysis of Saltwater Intrusion Effects into Coastal Aquifers in Korea considering Climate Change Effects (기후변화의 영향을 고려한 한반도 해안지역 대수층의 해수침투 영향 분석)

  • Yang, Jeong-Seok;Nam, Jae-Joon;Park, In-Bo;Kim, Sangdan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1B
    • /
    • pp.71-85
    • /
    • 2011
  • Saltwater intrusion effects of coastal aquifers in Korea peninsula were analyzed through trend analysis with groundwater level, seawater level, seawater temperature, and electrical resistivity(EC) data sets. Groundwater level and EC data sets from 27 coastal regions were collected and analyzed. Groundwater level was stable for all the regions however EC data showed stable or changing trends (9 increasing, 10 stable, and 8 decreasing regions). Seawater temperature was collected and analyzed for 14 regions and they are increasing for most regions (12 increasing and 2 stable regions). Seawater level was also collected and analyzed for 24 regions and is rising for most regions (18 rising, 3 stable, and 3 falling regions). Especially, west cost regions have stronger increasing tendencies of seawater level, seawater temperature, and EC than eastern and southern coastal regions. Therefore the saltwater intrusion problem can be serious for west cost regions in Korea peninsula and it is necessary to establish a plan to minimize the damages from saltwater intrusion.