누설전류로 인한 전기화재 및 감전사고 예방기법 (Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current)

  • 김동우;임용배;이상익;김재현;강대철
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

일반용 전기설비 안전점검의 전기화재 예방효과에 대한 정량적 분석 (Quantitative Analysis on the Electrical Fire Preventive Effect of Safety Inspection for Electrical Facilities for General Use)

  • 김택희;유재근;전정채
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.45-49
    • /
    • 2015
  • This paper presents a quantitative analysis method to quantitatively indicate a electrical fire preventive effect of safety inspection for electrical facilities for general use. Logic model was developed based on whether enforcement of safety inspection for electrical facilities, and then the developed analysis model was converted to hydraulic model by using mathematical logic. The electrical fire preventive effect of safety inspection for electrical facilities was quantitatively calculated by applying electrical safety inspection results and fire statistics for five years to the developed hydraulic model. The results show that electrical fire preventive effects of 5,542 cases on annual average for five years.

전기화재 통계 및 성과 분석 모델을 이용한 전기안전 긴급출동 고충처리 서비스의 비용 편익 분석 (Cost-Benefit Analysis of Electrical Safety Speed-call Service Using Electrical Fire Statistics Analysis and Outcome Analysis Logic Model)

  • 전정채;유재근
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1943-1947
    • /
    • 2016
  • Korea Electrical Safety Cooperation(KESCO) have provided the electrical safety speed-call service from 2007 year. Purpose of the service is to reduce discomfort of electricity use and to prevent electrical accident like as electrical fire and shock accident by providing emergency treatment service on fault of the residential electrical facilities notified in the specific house like as a lower-income group and a social welfare facility. But efficiency and economic evaluation of the electrical safety speed-call service is impossible because analysis on the quantitative effect of the service is difficult. This paper presents cost-benefit analysis method and result of the electrical safety speed-call service. The presented cost-benefit analysis method has a two-step process: the first step is to measure quantitative electrical fire prevention effect of the service by using electrical accident statistics and developing outcome analysis logic model of the service effect, and the second step is to analysis cost-benefit(B/C)of the service by calculating quantitative benefit analysis on the measured quantitative electrical fire prevention effect. The results showed that cost-benefit(B/C)of the electrical safety speed-call service is over 4 after 2010 year.

전기안전기술 로드맵 설계 연구 (A Study on the Roadmap Design for Electrical Safety Technology)

  • 신흥식;이재천;이병길
    • 대한안전경영과학회지
    • /
    • 제9권3호
    • /
    • pp.1-7
    • /
    • 2007
  • A roadmap for Electrical Safety Technology has been designed based on the study that has been contributed by the specialists, professors and researchers in electral safety field. The roadmap is divided into five major fields including, for instance, the electrical fire accidents roadmap. The other four roadmaps are for electrical shock accidents, electrical facilities accidents, electrical safety policies and electrical safety culture-education, respectively. Each roadmap has a purpose, a scope, and a technical characteristic. Following the roadmaps can result in significant reduction of electrical fire accidents, electrical shock accident victims and so forth. The result can also be utilized in guiding the planning and development of the future electrical safety technology.

전기 절연물의 오염에 따른 누설전류 특성 및 사고위험성 연구 (The Accident Hazard and Properties of the Leakage Current on the Electrical Insulation by Pollution)

  • 김영석;송길목;정진수;정종욱;김선구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.463-467
    • /
    • 2007
  • It is necessary to study the prevention and the management of electrical facilities because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

공연장내 간선설비에 대한 현장실태분석 연구 (A study on the analysis of actual main line systems of entertainment places)

  • 배석명;김한상;길형준;이건호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1765-1767
    • /
    • 2003
  • The standard of living has been getting higher by reason of industrialization and economic growth. It makes people have more cultural desire(wants). Because of reasons mentioned above, a number of entertainment place and performance with high-tech is increased. This has been brought also increasing a number of electrical accident such as electrical shock, electrical fires and accidents of electrical facilities. This paper suggests technical, operational and special precautions of actual electric main line systems in entertainment places and is also written on the purpose of being applied with related provisions to designing electrical facilities, construction, check-up and inspection and maintenance for preventing further electrical disasters in entertainment places.

  • PDF

분수대 전기설비의 국내 적용실태분석 (An investigation on the actual condition of electrical facilities in domestic fountains)

  • 김한상;김종민;황광수;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.44-46
    • /
    • 2005
  • An Electrical facilities of fountain is one of the vulnerable facilities because it is exposed to water. Especially, some children enter the fountain and play in the water in the hot season. For example, death from electrical shock in fountain was reported in domestic and foreign papers. In this paper, we analyzed the riskiness of electrical shock on the basis of a fact-finding survey and comparing the domestic and international standard of electrical facilities in fountains.

  • PDF

외부 오염 환경하에서 고분자 절연재료의 표면 누설전류 측정 및 열화 패턴 분석 (Deterioration Pattern Analysis and Surface Leakage Current of Electrical Insulation in External Pollution)

  • 김영석;송길목;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2080-2081
    • /
    • 2007
  • In this paper, the polymer insulators which had been used for electrical insulation were investigated surface leakage current and deterioration pattern. Because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

전기안전관리대행 제도의 합리적 운영 방안 (Reasonable Operation Method for Electrical Safety Management Agency System)

  • 김두현;김성철;이종호;김선구;황광수;김상철
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.14-19
    • /
    • 2012
  • This study proposes to suggest a direction hereafter which is the most suitable operating system of electrical safety management agency for electrical facilities to enhance electrical safety considering our domestic conditions. It was designed to prevent electrical disasters which are increasing due to environmental changes in the electrical industry, and the diversification and complication of the electrical facilities. And the strategy of this research is based on conditions of safety management agency for the electrical facilities, with the analysis on conditions of electrical disasters, and with a questionnaire investigation for owner of electrical facilities, safety management agency. Results of this research are expected to be used to prevent electric fires and shocks effectively by reinforcing the electrical safety management agency of electrical facilities having danger of large-scaled accidents. It is expected to enhance the nation's competing power against foreign countries by reducing the human and physical loss, resulted from the development of reasonable operating system for electrical safety management agency.