• Title/Summary/Keyword: Electric-Shock

Search Result 408, Processing Time 0.028 seconds

A Study on the Properties Analysis and Estimation of Odor Detection System (향 검지 시스템의 특성 해석 및 평가에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.1-5
    • /
    • 2009
  • We studies wish to investigated establishment form of cabinet board, and confirm possibility of electrical disaster prevention through reappearance experiment of odor detection system. Established breaker consists of MCCB, RCD order in cabinet board for house, but industry is used together with. When imposed shock using shaker to terminal block that contact becomes in appropriate, flame was made sure. According to result that experiment attaching odor capsule in terminal block, capsule commissioned exactly by occurred heat. According to establishment position of sensor, difference of inspection time was about 10 seconds. Estimate odor inspection system by thing which electrical device accident prevention is available. When there is abnormal generated heat in connection of electric wire, accident prevention estimates that is possible by giving an alarm state of overheat to administrator.

A Study on the Improving Direction of Container Housing through Field Survey - Based on the Analysis of 12 cases in the Urban Area - (국내 컨테이너 하우징의 실태조사를 통한 개선방향연구 - 수도권 지역의 12개 사례를 중심으로 -)

  • Yoo, Hae-Yeon;Park, Yeon-Jeong;Yoon, Jung-Yeon
    • Journal of the Korean housing association
    • /
    • v.23 no.6
    • /
    • pp.21-30
    • /
    • 2012
  • In foreign countries, the use of containers has already been stabilized with their advantages utilized in various forms. Containers are also utilized in Korea as various forms of architecture, but domestic container buildings have poor public consciousness so as to be limitedly utilized as temporary structures based on economic efficiency. Besides, there is the lack of research and development on them. Particularly, despite the advantages of containers as housing facilities, the use of containers as short- or middle-term temporary housing is limited and does not spread. Also, compared to general housing, containers have lower quality of physical environment and even frequently bring about negligent accidents such as fire and electric shock. Thus, this study intends to identify the actual condition of using container houses, the problems in using them, and the direction of improving their residential environment. For this purpose, it analyzes the present condition and characteristics of domestic container housing, and derives conclusions from the focus group interview with 23 residents who have lived in Seoul and Gyeonggi-do for over a year about such survey items as daylighting, ventilation, privacy condition, water service and sewerage, insulation, soundproofing, view, and room scale.

COMPUTATIONAL MODELING AND SIMULATION OF METAL PLASMA GENERATION BETWEEN CYLINDRICAL ELECTRODES USING PULSED POWER (펄스파워를 이용한 실린더형 전극간 금속 플라즈마 생성현상의 전산유동해석)

  • Kim, K.;Kwak, H.S.;Park, J.Y.
    • Journal of computational fluids engineering
    • /
    • v.19 no.4
    • /
    • pp.68-74
    • /
    • 2014
  • This computational study features the transient compressible and inviscid flow analysis on a metallic plasma discharge from the opposing composite electrodes which is subjected to pulsed electric power. The computations have been performed using the flux corrected transport algorithm on the axisymmetric two-dimensional domain of electrode gap and outer space along with the calculation of plasma compositions and thermophysical properties such as plasma electrical conductivity. The mass ablation from aluminum electrode surfaces are modeled with radiative flux from plasma column experiencing intense Joule heating. The computational results shows the highly ionized and highly under-expanded supersonic plasma discharge with strong shock structure of Mach disk and blast wave propagation, which is very similar to muzzle blast or axial plasma jet flows. Also, the geometrical effects of composite electrodes are investigated to compare the amount of mass ablation and penetration depth of plasma discharge.

Configuration of a Module for Monitoring Voltages Between Power Lines and Hull Onboard Vessels Based on the Vector Diagram at 3 Phase Ungrounded Power Distribution System (비접지 선박 3상 배전선로의 대지전압 벡터 모니터링 장치의 구성)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1111-1116
    • /
    • 2011
  • Power distribution systems onboard vessels are typically configured without any live line connected to hulls for earthing purpose, where the line to hull voltages are affected and deformed depending on the impedances consisting of insulation resistances and distributed capacitances between power lines and hull. An insulation fault at power lines causes the line to hull voltages to increase to a higher level which brings more possibilities to electric shock and deterioration of insulation material. This study focuses on how to configure a module which enables to continuously monitor the voltages between power line and hull based on the vector diagram by analyzing the neutral point of 3 phase voltages and the algorithm for plotting method on the PC monitors.

Pharmacological Actions of $\imath$--Muscone on Cerebral Ischemia and Central Nervous System ($\imath$-Muscone의 뇌허혈 및 중추신경계에 관한 약효연구)

  • 조태순;이선미;이은방;조성익;김용기;신대희;박대규
    • Biomolecules & Therapeutics
    • /
    • v.5 no.3
    • /
    • pp.306-315
    • /
    • 1997
  • In order to investigate pharmacological properties of ι -muscone, effects of ι-muscone and musk on cerebral ischemia and central nervous system were compared. Cerebral ischemia insult was performed using unilateral carotid artery occlusion in Mongolian gerbils. The histological observations showed a preventive effect of the ι-muscone treatment with ischemia-induced brain damage. The ATP in brain tissue was decreased in vehicle-treated ischemic gerbils. This decrease was prevented by the ι-muscone treatment. In contrast to what was seen with ATP, the lactate and lipid peroxide were both elevated in vehicle-treated ischemic gerbils.˙ This elevation was prevented by the ι-muscone treatment. While ι-muscone had no effects on the hexobarbital-induced sleeping time and the convulsions induced by electric shock, pentetrazol and strychnine, it had effect on rotarod test and spontaneous activity test. Respiration rate and depth were increased by the ι-muscone treatment. Furthermore, ι-muscone showed anti-stress effect. Our findings suggest that the pharmacological profile of ι-muscone on cerebral ischemia and central nervous system are similar to that of musk.

  • PDF

The status of parents' education and their perception for young children's safety (유아안전을 위한 부모교육의 경험 및 부모의 인식도)

  • Hong, Myoung-Hee;Chong, Young-Sook;Jang, Hye-Ja
    • Korean Journal of Human Ecology
    • /
    • v.13 no.5
    • /
    • pp.741-749
    • /
    • 2004
  • The purpose of this study was parents' perception on young children's safety life, safety accident, and safety education and provided basic data of administrating parent education for young children's safety. Subjects of this study were 620 parents (310 fathers and 310 mothers) of young children attending at four public kindergartens and two day care centers located in C city and D county. The results of the study were as follows: First, regarding parents' perception on young children's safety life, parents thought that their perception and attitude would mostly affect young children' safety life. Second, with regard to parents' perception on safety accident, half of parents experienced such safety accident as accident during play, traffic accident, accident in dangerous places, accident from dangerous matters, accident in sport activities, fire, and electric shock. Third, most parents looked upon safety education as very important one, and fathers were more satisfied with the safety education administered by kindergartens. Fourth, with regard to parents' perception on parent education for young children's safety, most parents thought that parent education for safety would be necessary. They ranked traffic and play accidents as the most important contents of safety education.

  • PDF

An Analysis of the Ground Potential Rises and Dangerous Voltages Associated with the Frequency of Ground Currents (접지전류의 주파수에 따른 대지표면전위 상승 및 위험전압의 분석)

  • Choi, Jong-Hyuk;Cho, Yong-Sung;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.97-103
    • /
    • 2011
  • The most important object of grounding systems is to protect human being from electric shock. Touch and step voltages are measured to evaluate the performances of grounding systems. Dangerous voltages have been largely studied by the power frequency fault currents, on the other hand, the ground current containing the high frequency components and surge currents haven't been considered. Many attempts about the grounding impedances reported in these days show that the performance of the grounding systems in high frequency range is very different with the ground resistance. It is necessary to analyze the dangerous voltages formed by the ground currents containing high frequency components. In this paper, the ground surface potential rises near the vertical and horizontal grounding electrodes are measured at the frequency of 100[Hz], 30[kHz], and 100[kHz]. Dangerous voltages are investigated with the frequency-dependent grounding impedance. As a result, the ground surface potential rise is increased as the grounding impedance increases. Touch and step voltages near the grounding electrode whose impedance increases with the frequency are sharply raised.

Study to Analyze the Grounding System in the 20 kHz Power Installation (20 kHz 전력설비 접지시스템 분석에 관한 연구)

  • Jung, Jin-Soo;Han, Woon-Ki;Park, Chan-Urm;Song, Young-Sang;Lim, Hyun-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1308-1312
    • /
    • 2013
  • In this paper, carried out for optimal ground system for ensuring safety for electricity used to power equipment in the 20 kHz frequency. Now the grounding system of the mesh electrode, electrode rods are installed for power plant safety and protection against electric shock. However, the electrical equipment grounding system in the 20 kHz were considering the increasing grounding impedance due to the high frequency and the magnetic shielding. But until now, there has been little research on the grounding system. To solve this problem, In this paper was proposed optimal grounding system due to the experiment using a mesh electrode, rod electrode, aluminum plate electrodes. Measurement results, grounding resistance was depending on the material of the electrode grounding resistance. In addition, the leakage current (induced) appeared to be affected depending on the type of electrode.

Study on Theoretical Research to Reduce Fire Risk of Solar Power System (태양광 발전 시스템의 화재 위험 감소 방안에 관한 이론적 연구)

  • Park, Kyong-Jin;Lee, Guen-Cull;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.219-224
    • /
    • 2020
  • This study is based on the principle of solar power system and fire breakout. The result of the survey indicates that a solar power system is vulnerable to fire due to lack of maintenance after the installation. Currently the national fire safety agency does not have standards and legal provisions for the installation and maintenance of solar power facilities. Therefore, it increases the risk of fire breakouts as well as possibility of electric shock for the firefighters during fire fighting. This results possible damages to the human and equipments. In this study is proposing an automatic fire extinguishing system to reduce the power generation of solar panels during fire breakouts. Also, propose an over load current alarm system and fire prevention measures for fire fighters. The results of this study will be used as basic data for further fire testing of solar power systems.

The auditory thresholds and fish behaviors to the underwater sounds for luring of target secies at the set-net in the coast of Cheju(II) -Critical ratios of the yellow tail(Seriola quinqueradiata)- (연안정치망 주요대상어종의 청각역치와 유집방음에 대한 행동반응(II) -방어(Seriola quinqueradiata)의 임계비)

  • 안장영
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.1
    • /
    • pp.19-24
    • /
    • 1999
  • This paper is second part on the auditory thresholds and fish behaviors to the underwater sounds for luring of target species at the set-net in the coast of Cheju. In order to obtain the critical ratio of yellow tails(Seriola quinqueradiata) and the emission level of underwater sound for luring of them, we make experiments to measure the auditory threshold of them using conditioning with electric shock. In state that the white noise with 10dB higher sound pressure level than ambient noise is emitted, the auditory thresholds of yellow tails are measured with 100~116.5dB and they are higher than those in state of no emission of white noise by the masking effects of it. Although sound pressure level of background noise go down, the auditory thresholds go up with frequency above than 300Hz.The critical ratio of yellow-tails in frequency of 80Hz, 100Hz, 200Hz, 500Hz, 800Hz are 46dB, 40dB, 50dB, 52dB, 60dB, 70dB respectively. The sound pressure level of which the signal sound is recognized by yellow tails under the ambient noise is above 100dB and the critical ratio of them is above 40dB.

  • PDF