• 제목/요약/키워드: Electric utility

검색결과 338건 처리시간 0.028초

적응 뉴로 퍼지 추론 시스템을 이용한 고임피던스 고장검출 (Detection of High Impedance Fault Using Adaptive Neuro-Fuzzy Inference System)

  • 유창완
    • 한국지능시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.426-435
    • /
    • 1999
  • A high impedance fault(HIF) is one of the serious problems facing the electric utility industry today. Because of the high impedance of a downed conductor under some conditions these faults are not easily detected by over-current based protection devices and can cause fires and personal hazard. In this paper a new method for detection of HIF which uses adaptive neuro-fuzzy inference system (ANFIS) is proposed. Since arcing fault current shows different changes during high and low voltage portion of conductor voltage waveform we firstly divided one cycle of fault current into equal spanned four data windows according to the mangnitude of conductor voltage. Fast fourier transform(FFT) is applied to each data window and the frequency spectrum of current waveform are chosen asinputs of ANFIS after input selection method is preprocessed. Using staged fault and normal data ANFIS is trained to discriminate between normal and HIF status by hybrid learning algorithm. This algorithm adapted gradient descent and least square method and shows rapid convergence speed and improved convergence error. The proposed method represent good performance when applied to staged fault data and HIFLL(high impedance like load)such as arc-welder.

  • PDF

탄소강배관 다중 UT 측정두께를 활용한 감육여부 판별법 개발 (Development of Wall Thinning Distinction Method using the Multi-inspecting UT Data of Carbon Steel Piping)

  • 황경모;윤훈;이찬규
    • Corrosion Science and Technology
    • /
    • 제11권5호
    • /
    • pp.173-178
    • /
    • 2012
  • To manage the wall thinning of carbon steel piping in nuclear power plants, the utility of Korea has performed thickness inspection for some quantity of pipe components during refueling outages and determined whether repair or replacement after evaluating UT (Ultrasonic Test) data. When the existing UT data evaluation methods, such as Band, Blanket, PTP (Point to Point) Methods, are applied to a certain pipe component, unnecessary re-inspecting situations may be generated even though the component does not thinned. In those cases, economical loss caused by repeated inspection and problems of maintaining the pipe integrity followed by decreasing of newly inspected components may be generated. EPRI (Electric Power Research Institute) in USA has suggested several statistical methods, TPM (Total Point Method), LSS (Least Square Slope) Method, etc. to distinguish whether multiple inspecting components have thinned or not. This paper presents the analysis results for multiple inspecting components over three times based on both NAM (Near Area of Minimum) Method developed by KEPCO-E&C and the other methods suggested by EPRI.

건물용 열병합발전 시스템의 적정규모 산정을 위한 최적 투자모형 (Optimal Sizing Evaluation Model of Building Cogeneration System)

  • 박종성;원선재;김정훈;박승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.117-119
    • /
    • 1995
  • For an effective application of the cogeneration system for commercial and industrial buildings, we need to develop a relevant model to determine the long-term based optimal sizing of the cogeneration system considering electrical and thermal load demands, buy and sell contracts with electric utility and the annual production cost. In assessing the optimal sizing of cogeneration, we have to consider both economic parameters and their capacity expansion for the increased electrical and thermals demand in the future. In this paper, we propose a mathematical model for the optimal sizing of cogeneration systems considering annual production costs and other economic parameter such as, lifetime of the equipment, time value of the capital, etc. In the case study, we thoroughly examine the effects of the economic parameters and determine the optimal size of the sample system. In addition, we calculate the payback period of the cogeneration investment.

  • PDF

Towards Cyber Security Risks Assessment in Electric Utility SCADA Systems

  • Woo, Pil Sung;Kim, Balho H.;Hur, Don
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.888-894
    • /
    • 2015
  • This paper presents a unified model based assessment framework to quantify threats and vulnerabilities associated with control systems, especially in the SCADA (Supervisory Control and Data Acquisition) system. In the past, this system was primarily utilized as an isolated facility on a local basis, and then it started to be integrated with wide-area networks as the communication technology would make rapid progress. The introduction of smart grid, which is an innovative application of digital processing and communications to the power grid, might lead to more and more cyber threats originated from IT systems. However, an up-to-date power system often requires the real-time operations, which clearly implies that the cyber security would turn out to be a complicated but also crucial issue for the power system. In short, the purpose of this paper is to streamline a comprehensive approach to prioritizing cyber security risks which are expressed by the combination of threats, vulnerabilities, and values in the SCADA components.

전류 벡터 포텐셜을 이용한 와류분포의 유한요소 해석에 관한 연구 (A Study on the finite Element Analysis of Eddy Current Distributions using Current Vector Potential)

  • 임달호;김민수;신흥교
    • 대한전기학회논문지
    • /
    • 제37권12호
    • /
    • pp.839-846
    • /
    • 1988
  • 전기기기의 와류분포를 해석하고자 항때 자기벡터포텐셜을 이용한 2차원적 해석법을 적용하면 해석영성내의 와류의 크기는 구할수 있지만 그 분포 양상은 알 수 없다. 이러한 문제점을 해결하기 위해 전류 벡터포텐셜을 도입하여 지배방정식을 유도하였으며 이에 유한요소법을 적용하여 2차원적 와류분포해석을 시도하였다. 그리도 시간술분항의 취급에는 시간영성가중계산법을 적용하였으며 이에 따른 알고리즘을 도출하였다. 또한 위에 방법을 해석해가 좌우하는 모델 및 와류에 의해 구동토오크가 발생하는 군상적산전력계 의 알루미늄 원판에 적용하여 해석한 결과 그 타당성 및 유용성을 입증할 수 있었다.

바이오에너지로의 전환을 위한 캘리포니아 식품가공공장 오.폐수 특성 조사 및 경제성 분석 (Survey and Economic Analysis of Food Industry Residues for Biomass-to-energy Conversion in Merced and Stanislaus Counties, California, USA)

  • 김대현
    • Journal of Biosystems Engineering
    • /
    • 제34권4호
    • /
    • pp.243-253
    • /
    • 2009
  • This research expands investigations into the biomass resource potential associated with California's food processing industry by surveying industries within a two county region in the San Joaquin Valley, California, USA. A previous survey conducted in 2005 for the Sacramento Municipal Utility District (SMUD) quantified residue and waste generation from food processors and food preparation businesses in the Sacramento region. The present survey investigates residue and waste streams from food processors located in Merced and Stanislaus Counties. Sixty food processors were identified to participate in the survey, of which 49 responded (82%) and data were acquired for 38 (63%) (6 facilities closed or moved, 8 decided not to participate). Within the two counties, total annual waste among survey respondents amounted to 24,044 dry tons of high moisture (${\geq}$60%) food residuals, 5,358 dry tons of low moisture (<60%) food residuals; and 23.7 million $m^3$ of wastewater containing 38,814 tons of biochemical oxygen demand ($BOD_5$). The total potential electric power generation from these food residues was estimated at approximately $7\;MW_e$. Total solid waste resource included in the survey response was estimated at about 10% of statewide residue generation for processors falling within the Standard Industrial Classification (SIC) System Major Group 20 (Food and Kindred Products) categories.

CO2 sequestration and heavy metal stabilization by carbonation process in bottom ash samples from coal power plant

  • Ramakrishna., CH;Thriveni., T;Nam, Seong Young;kim, Chunsik;Ahn, Ji Whan
    • 에너지공학
    • /
    • 제26권4호
    • /
    • pp.74-83
    • /
    • 2017
  • Coal-fired power plants supply roughly 50 percent of the nation's electricity but produce a disproportionate share of electric utility-related air pollution. Coal combustion technology can facilitate volume reduction of up to 90%, with the inorganic contaminants being captured in furnace bottom ash and fly ash residues. These disposal coal ash residues are however governed by the potential release of constituent contaminants into the environment. Accelerated carbonation process has been shown to have a potential for improving the chemical stability and leaching behavior of bottom ash residues. The aim of this work was to quantify the volume of $CO_2$ that could be sequestrated with a view to reducing greenhouse gas emissions and stabilize the contaminated heavy metals from bottom ash samples. In this study, we used PC boiler bottom ash, Kanvera reactor (KR) slag and calcined waste lime for measuring chemical analysis and heavy metals leaching tests were performed and also the formation of calcite resulting from accelerated carbonation process was investigated by thermo gravimetric and differential thermal analysis (TG/DTA).

TECHNICAL REVIEW ON THE LOCALIZED DIGITAL INSTRUMENTATION AND CONTROL SYSTEMS

  • Kwon, Kee-Choon;Lee, Myeong-Soo
    • Nuclear Engineering and Technology
    • /
    • 제41권4호
    • /
    • pp.447-454
    • /
    • 2009
  • This paper is a technical review of the research and development results of the Korea Nuclear Instrumentation and Control System (KNICS) project and Nu-Tech 2012 program. In these projects man-machine interface system architecture, two digital platforms, and several control and protection systems were developed. One platform is a Programmable Logic Controller (PLC) for a digital safety system and another platform is a Distributed Control System (DCS) for a non-safety control system. With the safety-grade platform PLC, a reactor protection system, an engineered safety feature-component control system, and reactor core protection system were developed. A power control system was developed based on the DCS. A logic alarm cause tracking system was developed as a man-machine interface for APR1400. Also, Integrated Performance Validation Facility (IPVF) was developed for the evaluation of the function and performance of developed I&C systems. The safety-grade platform PLC and the digital safety system obtained approval for the topical report from the Korean regulatory body in February of 2009. A utility and vendor company will determine the suitability of the KNICS and Nu- Tech 2012 products to apply them to the planned nuclear power plants.

SVPWM 방식 마이크로소스로 구성된 마이크로그리드 모델링 및 해석 (Modeling and Analysis of the Micro-Grid with SVPWM Micro-Sources)

  • 손광명;이계병;김영섭
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.12-19
    • /
    • 2006
  • 마이크로소스는 1[kW]${\sim}$수[MW] 사이의 전력을 공급하고, 기존의 대규모 발전설비보다 높은 신뢰도와 에너지 효율을 가지는 고품질의 전력을 공급할 수 있다. 본 논문에서는 마이크로소스의 스위칭레벨 모델을 개발하였으며, 다수의 마이크로소스가 전력시스템과 연계되어 마이크로그리드를 형성할 경우의 특성에 대하여 연구하였다. 마이크로소스는 인버터의 효율을 극대화 할 수 있도록 공간벡터 펄스폭변조(Space Vector PWM, SVPWM) 기법을 채용하였으며, 마이크로소스의 제어시스템 파라미터 특성 및 마이크로소스 상호작용에 관하여 연구하였다. 마이크로소스는 PSCAD/EMTDC를 이용하여 구현하였으며 이를 이용해 마이크로그리드를 구성하여 시뮬레이션하였다. 사례 연구를 통하여 제안된 모델의 효용성을 확인하였다.

Development of Customer Oriented Load Management Software for Savings on Utility Bills in the Electricity Market

  • Chung, Koo-Hyung;Lee, Chan-Joo;Kim, Jin-Ho;Hur, Don;Kim, Balho-H.;Park, Jong-Bae
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.42-49
    • /
    • 2007
  • For electricity markets to function in a truly competitive and efficient manner, it is not enough to focus solely on improving the efficiencies of power supply. To recognize price-responsive load as a reliability resource, the customer must be provided with price signals and an instrument to respond to these signals, preferably automatically. This paper attempts to develop the Windows-based load management system in competitive electricity markets, allowing the user to monitor the current energy consumption or billing information, to analyze the historical data, and to implement the consumption strategy for cost savings with nine possible scenarios adopted. Finally, this modeling framework will serve as a template containing the basic concepts that any load management system should address.