• Title/Summary/Keyword: Electric utilities

Search Result 160, Processing Time 0.026 seconds

The Study of the Automation Systems using Satellite Communications (위성통신을 이용한 자동화 감시 시스템 구축 연구)

  • Kim, Myong-Soo;Hyun, Duck-Hwa;Cho, Seon-Ku;Kim, Choong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2540-2542
    • /
    • 2002
  • In recent years, it is a worldwide trend that many power utilities focus their attention to employ up-to-date communication technology to the automation of their power plants and distribution systems. Automation Systems in Korea was installed using twisted pair cable(TPC), power line carrier(PLC), coaxial cable(CA), wireless network(wireless data, TRS and PCS). Among the communication media only Satellite Communication guarantees the reliable communication in case of emergency such as a flood, a heavy snow and an earthquake. It can integrate two-way satellite systems to existent nationwide SCADA controlling points of electric power transmission & distribution system that enables real time remote monitoring and controlling automatically. This paper presents some of design efforts for the satellite communication network as the media of Automation Systems.

  • PDF

Impact Assessment of Plug-in Hybrid Electric Vehicles on Electric Utilities (플러그인 하이브리드 자동차의 시장 형성 시의 전력망에의 영향 분석)

  • Roh, Chul-Woo;Kim, Min-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2001-2006
    • /
    • 2008
  • The most concerning issue of these days is the energy crisis by increasing threat of dependency on foreign oil and its volatility itself. In the situations, the PHEV is drawing attention for the next generation's car which could give a chance to decrease the dependency on foreign oil. As well as, the Korean electric power infrastructure is a strategic national asset that is under utilized most of the time. With the proper changes in the operational paradigm, it could generate and deliver necessary energy to charge the PHEVs which could penetrate the market within few years. In doing so, it would reduce greenhouse gas emissions, improve the economics of the electricity industry, and reduce the energy dependency. This paper investigate the technical potential and impacts of using the existing idle capacity of the electric infrastructure in conjunction with the emerging PHEVs technology to meet the majority of daily energy needs of the Korean LDV fleet.

  • PDF

Power Quality Index and Cost based on Load-Voltage Characteristics (부하의 전압특성을 고려한 모선별 전력품질 지표 및 가격 산정기법)

  • 이근준
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.213-218
    • /
    • 2003
  • In front of the opening of electric distribution market in 2004, it is indispensable to have a proper estimation of power quality index and rower quality cost calculation mechanism which are indispensable to stabilize highly industrialized society and to vitalize the Investment lot electric power system. However, there were not enough measures to reflect the voltage characteristics such as voltage sags and Interruptions which make electric load in unstable operation. This paper suggests power quality index and power quality cost which translate various kinds of voltage records into bus load drop index(BLDI) and bus power quality cost(BPQC) based on aggregated load CBEMA curve. A sample calculation result shows that this method can produces the acceptable power Quality index and costs for utilities and customers requirements.

NSE-Sponsored Faculty Workshops on Teaching of Power Electronics and Electric Drives

  • Ned Mohan;Jain, Amit-Kumar
    • Journal of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.231-239
    • /
    • 2002
  • This paper describes the restructuring of power electronics and electric drives courses, sponsored by NSF, EPRI, NASA and the local utilities, which has significantly increased student enthusiasm, and the undergraduate enrollment in these courses at the University of Minnesota has tripled since 1997. The developed leaching approaches have been the subject of NSF-sponsored faculty workshops in 1994, 1997, 1998,2002, and 2003. In power electronics, the power-pole based building-block approach unifies analysis and control aspects of all converters. PSpice-based simulations aid in analysis and design, supported by a hardware laboratory. For electric drives, an integrative approach addressing all three aspects of electric drives - machines, power converters and control is being. used. Space vectors, introduced on a physical basis rather than purely mathematical ions, are used fur analysis of ac machines. This leads to a more physical understanding of machine operation and also makes it easier to address control aspects in the advanced course. The lecture materials are supported by a DSP-based laboratory.

A Research to Minimizing the Effect of Voltage Disturbances on Sensitive Electrical and Electronic Equipment (민감한 전기전자기기의 전압외란에 대한 영향 최소화 연구)

  • 윤갑구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.2
    • /
    • pp.10-20
    • /
    • 1986
  • This paper describes a countermeasure of electric utilities and customer equipment in order to minimize an effect of sensitive electrical and electronic equipment on the voltage disturbances. After being studied, some schemes to solve were discovered. Firstly, in the electric utilities, the reduction of frequency and influence of voltage drop's time are not easy to realize because of the standpoint of effect and economy. Secondly, in the customer equipment, there are some equipment to minimize the voltage disturbances, Such as an UPSs, a noise suppressors and a power conditioners. One of them should be established on the computer control and automated systems, the electromagnetic switch of delay-release type should be adopted on the electromagnetic switch, the controlling circuit should be adopted on the variable speed motors which is being considered a countermeasure for a momentary under-voltage drops, the luminaire adhering a instantaneous restrike device should be adopted on the HID lamp. And also, the scheme of extending a setting time of relay on the undervoltage relay and the forming method of sequence which is automatic reclosing at this time of instantaneous suspension of an electric supply have been studied.

  • PDF

Design of CIM(Common Information Model) Profile for Smart City Energy Monitoring (스마트시티 에너지 감시를 위한 CIM(Common Information Model) 프로파일 설계)

  • Youngil, Kim;Changhun, Chae;Yeri, Kim;Jihoon, Lee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.127-135
    • /
    • 2022
  • With the advent of high technologies such as the 4th Industrial Revolution and artificial intelligence and big data, efforts are being made to solve urban problems and improve the quality of life by applying new technologies in the smart city field. In addition, as carbon neutrality has emerged as an important issue due to global warming, smart city energy platform technologies such as urban energy management, efficiency improvement, and carbon reduction are in the spotlight. In order to effectively manage urban energy, energy resource information such as electricity, water, gas, hot water, heating, etc. must be collected from the management system of various energy utilities and managed on the central platform. The centrally integrated data is delivered to external city management systems that require city energy information through an energy platform. This study developed a CIM profile for smart city energy monitoring required to provide energy data to external systems. Electric data model were designed using the CIM class of IEC 61970, and water, gas, and heat data model were designed in compliance with the UML-based design ideas of IEC 61970.

RNN NARX Model Based Demand Management for Smart Grid

  • Lee, Sang-Hyun;Park, Dae-Won;Moon, Kyung-Il
    • International Journal of Advanced Culture Technology
    • /
    • v.2 no.2
    • /
    • pp.11-14
    • /
    • 2014
  • In the smart grid, it will be possible to communicate with the consumers for the purposes of monitoring and controlling their power consumption without disturbing their business or comfort. This will bring easier administration capabilities for the utilities. On the other hand, consumers will require more advanced home automation tools which can be implemented by using advanced sensor technologies. For instance, consumers may need to adapt their consumption according to the dynamically varying electricity prices which necessitates home automation tools. This paper tries to combine neural network and nonlinear autoregressive with exogenous variable (NARX) class for next week electric load forecasting. The suitability of the proposed approach is illustrated through an application to electric load consumption data. The suggested system provides a useful and suitable tool especially for the load forecasting.

Investigation on the Commercialization Issues of Resistive Type Superconducting Fault Current Limiters for Electric Networks

  • Park, Tae-Gun;Lee, Sang-Hwa;Lee, Bang-Wook
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • Among the various types of fault current limiters, superconducting fault current limiters could be the most preferable choice for high voltage electric power systems owing to the remarkable current limiting characteristics of superconductors. But, there have been no commercial superconducting fault current limiters which were installed into actual electric power systems until these days due to some remained technical and economical problems. Thus, in order to promote the development and application of the superconducting fault current limiters into real field, it is essential to understand the power utilities’ requirements for their networks and also suitable test method and some specifications should be prepared. This paper focuses on the matters of test requirements and standardization issues that should be prepared for commercialization of superconducting fault current limiters. The unique current limiting characteristics of superconducting fault current limiters were investigated and related other standards including circuit breakers, transformers, reactors, power fuse, and fused circuit breakers were compared to setup the basis of novel specification of superconducting fault current limiters. Furthermore, required essential test procedures for superconducting fault current limiters were suggested.

  • PDF

POWER LOAD MANAGEMENT FOR PEAK LOAD CLIPPING (POWER LOAD DIRECT CONTROL METHOD) (Peak부하(負荷) 억제(抑制)를 위한 전력부하관리(電力負荷管理) (전력부하(電力負荷) 직접제어방식(直接制御方式)))

  • Kim, Yeong-Han;Lee, Hyo-Sang;Kim, Jai-Young
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.246-250
    • /
    • 1989
  • Owing to the rapid development of economy and the higher living standard of people, electricity demands have growth and the peak load has been increased rapidly. To cope with this impacts and to reduce the cost of service,utilities are conserned about power load management program. This paper shows a scheme of power load control and the basic structure of direct load control system. And also radio control method using the public pager which is one of the best economical and serviceable method in techniques will be introduced briefly.

  • PDF

The Study on the Distribution Automation System using Optical Network (배전자동화 시스템용 광네트워크 구성 및 운용방안에 관한 연구)

  • Kim, Myong-Soo;Ko, Sang-Chon;Kim, Yong-Pal
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.558-560
    • /
    • 1997
  • In recent years, it becomes a worldwide trend that the power utilities focus their attention to the automation of their power plants and distribution systems, employing recent developed communication technologies. Following this trend, KEPCO has installed optical communication links along its power distribution lines and at the same time, has exhausted much efforts to implement its own Distribution Automation Systems(DAS) in possible early date. This paper presents some of initial design efforts toward KEPCO's DAS at KEPRI.

  • PDF