• Title/Summary/Keyword: Electric spring

Search Result 162, Processing Time 0.026 seconds

Comparative Study on the Runoff Process of Granite Drainage Basins in Korea and Mongolia

  • Tanaka, Yukiya;Matsukura, Yukinori
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.79-84
    • /
    • 2003
  • This study revealed the differences in runoff processes of granite drainage basins in Korea and Mongolia by hydrological measurements in the field. The experimental drainage basins are chosen in Korea (K-basin) and Mongolia (M-basin). Occurrence of intermittent flow in K-basin possibly implies that very quick discharge dominates. The very high runoff coefficient implies that most of effective rainfall quickly discharge by throughflow or pipeflow. The Hortonian overlandflow is thought to almost not occur because of high infiltration capacity originated by coarse grain sized soils of K- basin. Very little baseflow and high runoff coefficient also suggest that rainfall almost does not infiltrate into bedrocks in K-basin. Flood runoff coefficient in M-basin shows less than 1 %. This means that most of rainfall infiltrates or evaporates in M-basin. Runoff characteristics of constant and gradually increasing discharge imply that most of rainfall infiltrates into joint planes of bedrock and flow out from spring very slowly. The hydrograph peaks are sharp and their recession limbs steep. Very short time flood with less than 1-hour lag time in M-basin means that overland flow occurs only associating with rainfall intensity of more than 10 mm/hr. When peak lag time shows less than 1 hour for the size of drainage area of 1 to 10 km2, Hortonian overland flow causes peak discharge (Jones, 1997). The results of electric conductivity suggest that residence time in soils or weathered mantles of M-basin is longer than that of K-basin. Qucik discharge caused by throughflow and pipeflow occurs dominantly in K-basin, whereas baseflow more dominantly occur than quick discharge in M-basin. Quick discharge caused by Hortonian overlandflow only associating with rainfall intensity of more than 10 mm/hr in M-basin.

  • PDF

A study on economic evaluation when renewable energy system is introduced in public buildings inside of Daegu Sin-seo innovation city (대구신서혁신도시 내 공공건축물의 신재생에너지 시스템 도입시 경제성 평가에 관한 연구)

  • Kim, Bo-Ra;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.175-180
    • /
    • 2009
  • According to an increasing demand of political support and development on renewable energy as a solution for the energy problem in Korea, the government has established a goal to raise renewable energy supply from 2.27% to 5% until 2011. Especially in the case of public building in which energy use is in great demand, it would bring a great advantage to develop and utilize the Photovoltaic System as an electric energy and Geothermal Heat Pump System as a thermal energy. On the occasion of Photovoltaic System, Photovoltaic module can be used as an architectural material so that it can reduce construction cost and when we use solar energy, it is possible to make building's own power supply. As for Geothermal Heat Pump System, It can be used infinitely as long as the solar energy exist and operation cost is cheap and yearly efficiency is stable. However, we need to make a plan to reduce early investment expanses for these two renewable energy systems and to expand a diffusion rate as we develop a competitive domestic technology level. So in this study, we are going to perform evaluation of economical efficiency according to the introduction of Photovoltaic System and Geothermal Heat Pump System in public buildings which will be built up inside of Daegu Sin-seo innovation city. As a first step, we will investigate present installation condition of these two renewable energy systems and based upon that, will seek efficient introduction program of renewal energy systems that can be applied in public buildings.

  • PDF

Perception on Residential Environment Planning for Seniors among University Students visited Aging Simulation Center (노인을 위한 주거환경계획 의식에 관한 연구 - 노인생애체험센터를 방문한 예비디자이너를 중심으로 -)

  • Shin, Hwa-Kyung;Lee, Yun-Hee;Kim, Young-Joo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.322-326
    • /
    • 2008
  • Due to the rapid increasing in the aged population, it calls for social countermeasures urgently. Especially, there are increasing needs of space environment to support physical and spiritual characteristics of elderly. When designing space environment including house, there are growing consideration for elderly and extending appreciation of aging. The purpose of this study is to investigate the perception on environment planning for the seniors among university students who majoring in Housing & Interior Design and who visited the Aging Simulation Center located in Seoul. The Aging Simulation Center gives a chance of space design to support the elderly based on the experiences of daily living for the designers who design environment for elderly. Questionnaire survey was conducted to obtain data from 93 university students in their 20s majoring in housing and interior design who visited the Aging Simulation Center. The research findings showed that the recognition for design elements of residential environment for the elderly of respondents was changed toward positive way after visiting the Aging Simulation Center. The Aging Simulation Center was an effective educational environment for the preliminary designers to understand aging and the importance of appropriate design for users' needs. That is, aging simulation space can improve recognition of necessity of universally designed environment to support the elderly. Handrails around bathtub and wash basin, stair slope, electric auto-level controlled kitchen counter and kitchen cabinet were especially perceived for the respondents as very essential design elements to support the aged.

  • PDF

Analysis of Irradiation and Power per Each Seasons of Photovoltaic Systems (태양광 발전시스템의 계절별 일사량과 전력량 분석)

  • Kim, Seok-Gon;Hwang, Jun-Won;Lee, Ying;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.43-45
    • /
    • 2009
  • In case of favourable irradiation conditions, the ratio of irradiation to the total irradiation went up and then the irradiation increased in the area with high angle of inclination. The study showed that on a clear day with the irradiation of more than 80$[W/m^2]$, the pattern of alternating current power change in the fixed system was similar with that in the single-axis tracker. On the contrary, in case of unfavourable irradiation conditions, the ratio of diffuse irradiation to the total irradiation went up and then the horizontal irradiation increased. In the demo system, the fixed system, the single-axis tracker and the dual-axis tracker all had low generation power and similar generation pattern with each other. The study showed the generation power varied with the irradiation in the fixed system, while in the single-axis tracker and the dual-axis tracker, the amount of the generation Power variation was much more than the irradiation variation. The demo system was operated from 11:00 AM to 2:00 PM for generating power, during which time, 46[%] to 56[%] of the total generation power was produced. In this study, the generation power was increased by 147[%] in the fixed system, by 136[%] in the single-axis tracker, and by 164[%] in the dual-axis tracker, and the pattern of generation power was similar with the generation power variation in the situation where the irradiation increased by 140[%] in the spring with plenty of insolation. The alternating current power was more sensitive to variation of the irradiation than to that of the surface temperature of a module. The variation of the irradiation had a more positive effect on the generation power than the type of array.

  • PDF

Effects of Fire on KDICical Properties of Soil and Runoff, and Phytomass in Pinus densiflora Forest Effects of Fire on KDICical Properties of Soil and Runoff, and Phytomass in Pinus densiflora Forest Effects of Fire on KDICical Properties of Soil and Runoff, and Phytomass in Pinus densiflora Forest (산화가 소나무림의 토양과 유출수의 화학적 성질 및 식물량에 미치는 영향)

  • Choung, Yeon Sook;Joon Ho Kim
    • The Korean Journal of Ecology
    • /
    • v.10 no.3
    • /
    • pp.129-138
    • /
    • 1987
  • In a red pine (Pinus densiflora) forest, changes of pH, electric conductivity, total carbon, total nitrogen, available phosphate and available potassium in soil and runoff have been studied at intervals for 1 year after early spring fire. Phytimasses of herb and shrub were measured following the current and the subsequent year. The pH, E.C., total nitrogen and phosphate of soil in burned site wee 1.1, 1.5, 1.6 and 2.0 times higher than in unburned site, respectively. But potassium showed no significant difference. A rise in pH, E.C., and total nitrogen in burned site were maintained throught the study period while phosphate maintained 4 months after the fire. The E.C., total carbon, $NO_2-N$ and $NH_4-N$ of runoff in burned site were 1.3, 1.3, 1.3 and 29.0 times higher than in unburned site, respectively, while $NO_3-N$ in unburned site was 4 times higher than in burned site. In burned site, phytomasses of herb and shrub were 148 and 33% of unburned site in a current year and 107 and 51% in a subsequent year, respectively. The considerable amount of increase in soil nutrient after the fire was conserved by the uptake of the fast regrowing plants and by the immobilization of $NH_4=N$.

  • PDF

Driving Characteristics of the Scanning Mirrors to the Different width and Number of the Grooves on the Electrodes (전극 홈 형상에 따른 스캐닝 미러의 구동 특성)

  • Park, Geun-U;Kim, Yong-Gwon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.11
    • /
    • pp.575-580
    • /
    • 2001
  • In this paper, using $500\mum-thickness\; (100)\; silicon\; wafer,\; flat\; 65\mum-thickness$ silicon mirror plates were fabricated through dry etching and wet etching, and $45\mum-depth$ grooved driving electrodes were fabricated through UV-LIGA process. Four shapes of the driving electrode were fabricated: twenty four grooves of the $50\mum-width$, twelve grooves of the $100\mum-width$, six grooves of the $200\mum-width$, and no grooves on the driving electrode. Fabricated mirror plate size and spring size are $2400\times2400\times65\mum3\; and \;500\times10\times65\mum3,$ respectively. Mirror plate parts and driving electrodes were assembled into the scanning mirrors. Measured natural resonance frequencies were about 600Hz which have error within $\pm 2%$ to calculated value. Due to the squeeze effect in the narrow gap between the mirror plate and the driving electrode, measured resonance frequencies were reduced as raising the amplitude of the mirror plate. In a case of driving electrode without grooves, the resonance frequency was reduced largely, compared with a case of driving electrode with grooves. According to the experimental results, squeeze effect was smaller in the driving electrode with smaller-width and many grooves. Therefore, the driving electrode with smaller-width and many grooves was effective in low voltage and high speed operation.

  • PDF

Development of Local Ground Pantograph for Power Supply to Wireless Mountain Trams (무가선 산악트램 급전을 위한 지상 집중식 급전장치 개발)

  • Seo, Sung-il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.268-275
    • /
    • 2020
  • In domestic mountain resort areas, a catenary system cannot be installed for the protection of the natural environment and view. Therefore, mountain trams must be operated wireless. In this study, a local ground pantograph, which supplies electricity to the battery on board, was developed for this purpose, and its performance was verified by tests. The system is installed on ground at stops or repair shops. While a bogie goes to the pantograph, the arms and collection shoes are raised by a spring force to make contact with the collection bar under the bogie so electric power can be supplied to the battery. Because it is a local ground type, it does not require a roof pantograph and catenary system. The system enables the mountain tram to run wireless. In addition, there is no separation and arc because it collects current while standing at stops or shops. The system has a long life because moving contact, which generates wear and damage to shoes, is avoided. The insulation resistance was above the criteria of 10 ㏁, and there was no abnormal temperature increase when a current of 335A was supplied for one hour.

Design and Implementation of Clutch-by-wire System for Automated Manual Transmissions (자동화 수동 변속기의 CBW 시스템 개발)

  • Moon, Sang-Eun;Kim, Min-Sung;Yeo, Hoon;Song, Han-Lim;Han, Kwan-Soo;Kim, Hyun-Soo;Hwang, Sung-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.119-128
    • /
    • 2004
  • With the growing traffic density and increasing comfort requirements, the automation of the drive train will gain importance in vehicles. The automatic clutch actuation relieves the drivers especially in urban driving and stop-and-go traffic conditions. This paper describes the dynamic modeling of a clutch actuator and clutch spring. The dynamic model of the clutch system is developed using MATLAB/Simulink, and evaluated by experimental data using a test rig. This performance simulator is useful to develop the clutch-by-wire (CBW) system for an automated manual transmission (AMT). The electro-mechanical type CBW system is also implemented as an automatic clutch for AMT. The prototype of CBW system is designed and implemented systematically, which is composed of an electric motor, worm gear and slider-crank mechanism. The test rig is developed to perform the basic function test of the automatic clutch, and the developed prototype is validated by the experimental data on the test rig.

Chemical Composition Characteristics of Precipitation at Two Sites in Jeju Island

  • Kang, Chang-Hee;Kim, Won-Hyung;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.3
    • /
    • pp.363-368
    • /
    • 2003
  • The major ionic components of precipitation collected at the 1100 Site of Mt. Halla and Jeju city have been determined. The reliability of the analytical data was verified by the comparison of ion balances, electric conductivities and acid fractions; all of their correlation coefficients were above 0.94. Ionic strengths lower than $10^{-4}$ M were found in 53% of the 1100 Site samples and 28% of the Jeju city samples. Compared with other inland areas, the wet deposition of $Na^+,\;Cl^-\;and\;Mg^{2+}$ was relatively larger, but that of $NH_4^+,\;nss-SO_4^{2-}$(non-sea salt sulfate) and $NO_3^-$ was lower. Especially the wet deposition increase of $Ca^{2+}$ in the spring season supports the possibility of the Asian Dust effect. The acidification of precipitation was caused mostly by $SO_4^{2-}\;and\;NO_3^-$ in the Jeju area, and the organic acids have contributed only about 7% to the acidity. The neutralization factors by NH₃were 0.47 and 0.48, and that of CaCO₃was 0.31 and 0.25 at the 1100 Site and Jeju city, respectively. Investigation into major influencing sources on precipitation components by factor analysis showed that the precipitation at the 1100 Site had been influenced mostly by an anthropogenic source, followed by soil and seawater sources. The precipitation at Jeju city was mainly influenced by oceanic sources, followed by anthropogenic and soil sources.

A Case Study of Decreasing Environment Pollution Caused by Energy Consumption of a Dormitory Building Which Only Using Electricity by Efficiently Simulating Applying Residential SOFC (Solid Oxide Fuel Cell)

  • Chang, Han;Lee, In-Hee
    • Architectural research
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • Recent years in Korea, some new developed buildings are only using electricity as power for heating, cooling, bathing and even cooking which means except electricity, there is no natural gas or other kinds of energy used in such kind of building. In vehicle industry area, scientists already invented electric vehicle as an environment friendly vehicle; after that, in architecture design and construction field, buildings only using electricity appeared; the curiosity of the environment impact of energy consumption by such kind of building lead me to do this research. In general, electricity is known as a clean energy resource reasoned by it is noncombustible energy resource; however, although there is no environmental pollution by using electricity, electricity generation procedure in power plant may cause huge amount of environment pollution; especially, electricity generation from combusting coal in power plant could emit enormous air pollutants to the air. In this research, the yearly amount of air pollution by energy using under traditional way in research target building that is using natural gas for heating, bathing and cooking and electricity for lighting, equipment and cooling is compared with yearly amount of air pollution by only using electricity as power in the building; result shows that building that only uses electricity emits much more air pollutants than uses electricity and natural gas together in the building. According to the amount of air pollutants comparison result between two different energy application types in the building, residential SOFC (Solid oxide fuel cell) is simulated to apply in this building for decreasing environment pollution of the building; furthermore, high load factor could lead high efficiency of SOFC, in the scenario of simulating applying SOFC in the building, SOFC is shared by two or three households in spring and autumn to increase efficiency of the SOFC. In sum, this research is trying to demonstrate electricity is a conditioned environment friendly energy resource; in the meanwhile, SOFC is simulated efficiently applying in the building only using electricity as power to decrease the large amount of air pollutants by energy using in the building. Energy consumption of the building is analyzed by calibrated commercial software Design Builder; the calibrated mathematical model of SOFC is referred from other researcher's study.