• 제목/요약/키워드: Electric shock accident

검색결과 51건 처리시간 0.023초

CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구 (A study on the Grounding method for reduce an interference by CATV Transmission Line)

  • 황종선;연제진;박성진;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구 (A study on the Grounding method for reduce an interference by CATV Transmission Line)

  • 황종선;연제진;박성진;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

전기화상 환자에서 나타난 파상풍-증례보고 (TETANUS TRISMUS ASSOCIATED WITH FACIAL ELETRICAL BURN)

  • 하태영;강진한;신미란;안병근;김미자
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권4호
    • /
    • pp.380-383
    • /
    • 2006
  • Tetanus is rare in Korea due to the introduction of vaccination programs and the advancement in public health. Its common signs are trismus, voice disturbance, neck stiffness, and difficulty in swallowing, etc. A 56 years old man was injured by grasping a high voltage electric cable. After the accident, he fell down on a steel plate and had a head trauma. When he visited Emergency Department, there was multiple electric burn wound on left arm and left facial area. He was hospitalized on a department of neurosurgery, because intra cranial hemorrhage was presumed. 12 days later, he was referred to department of OMFS with developed painful masseter spasms and trismus. That night he violently bit his tongue with his denture. Because masseter muscle and temporal muscle constriction was involuntary, tongue was lacerated and denture was distorted. At first we supposed that the symptom was related with neurologic disturbance following head trauma or electric shock. But it was revealed that trismus was caused by tetanus on an electrophysiological test. By using mechanical ventilation and administration of tetanus immunoglobulin, muscle-relaxant, and sedatives at ICU, symptoms had subsided (4-weeks). Because tetanus is rare disease, we rarely suppose tetanus infection to be a cause of a trismus. Especially it is more difficult to diagnose in patient who has head trauma, burn and neurologic problem as in this case.

변류기 2차측 개방 보호장치 개발 및 특성 (Development and Characteristics of Detector for Open of Current Transformer Secondary Terminal)

  • 최상원;송기찬
    • 한국안전학회지
    • /
    • 제22권4호
    • /
    • pp.20-25
    • /
    • 2007
  • Instrument transformers are a safe measurement device designed to measure high voltage and large current. A current transformer(CT) is a type of instrument transformer designed to provide a current in its secondary winding proportional to the current flowing in its primary. It is commonly used in metering and protective relaying in the electrical power industry where it facilitates the safe measurement of large current. But, care must be taken that the secondary of a current transformer is not disconnected from its load while current is flowing in the primary, as this will produce a dangerously high voltage across the open secondary, and may permanently affect the accuracy of the transformer. Especially, industrial disaster such as an electric shock and/or a burn accident occurs occasionally by disregard of warning or attention. In this paper, we developed the detector for open of current transformer secondary terminal, and which was tested by the Korea Electrotechnology Research Institute. Test results show that Current Transformer secondary Open Detector(CTOD) interrupted within one second electronically when the 2nd terminal of current transformer opened.

정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구 (A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors)

  • 최충석
    • 한국안전학회지
    • /
    • 제28권2호
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.

해안지역에서의 저압용 누전차단기 교체주기 연구 (A Study on the Life Time of RCD in Coastal Area)

  • 김종민;최명일;송길목;서정열;신진용;김창환
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.85-92
    • /
    • 2011
  • The role of RCDs(Residual Current Protective Device) that are installed before the load is very important for preventing electric shock and electrical fire. However, although fault rate of RCD is increasing due to deterioration and long period usage, the RCD is permanently used without a checking of performance evaluation and it causes the electrical accident. In this paper, the amount of airborne chloride is researched in domestic costal area and the accelerated life test is conducted using a salt water spray tester in order to decide the life time of RCD. Aa a result of an accelerated life test, the MTTF(Mean Time To Failure) of RCD is 110.81 hours and B10 life time of RCD is 45.81 hours for the all samples. when an accelerated life test result is applied to within 2 km costal area, the life time of RCD is predicted about 5 years.

딥러닝 기반 분류 모델의 성능 분석을 통한 건설 재해사례 텍스트 데이터의 효율적 관리방향 제안 (A Suggestion of the Direction of Construction Disaster Document Management through Text Data Classification Model based on Deep Learning)

  • 김하영;장예은;강현빈;손정욱;이준성
    • 한국건설관리학회논문집
    • /
    • 제22권5호
    • /
    • pp.73-85
    • /
    • 2021
  • 본 연구는 딥러닝 기반의 텍스트 데이터 분류 모델의 성능 고찰을 통해 한국어 건설 재해사례의 효율적 관리방향을 제안한다. 이를 위해 비정형 텍스트 문서인 건설 재해 보고서를 활용해 건설 사고의 대표적 유형인 추락, 감전, 낙하, 붕괴, 협착의 5개 범주로 분류하는 딥러닝 모델을 구현하였다. 초기 모델 테스트 결과, 추락 재해의 분류 정확도가 상대적으로 높게 도출되며 타 유형을 추락 재해로 분류하는 경우가 많이 발생한다는 특징이 나타났다. 원인 분석 결과, 1) 구체적인 사고 유발 행동, 2) 유사한 문장 구조, 3) 여러 유형에 해당되는 복합사고가 위의 특징에 영향을 미치는 것으로 분석되었으며, 이 중 추가 실험을 통해 검증이 가능한 복합사고에 대한 두 가지 정확도 개선 실험을 진행하였다: 1) 재분류, 2) 제외. 실험 결과, 복합사고 제외 시 분류 성능이 185.7% 향상되었으며, 이를 통해 여러 사고 유형에 대한 내용을 동시에 포함하는 복합사고의 다중공선성(multicollinearity)이 해소되었음을 알 수 있다. 결론적으로 본 연구에서는 향후 사고에 대한 상황을 상세히 서술하는 체계를 마련함과 동시에 복합사고를 독립적으로 관리할 필요성을 시사한다.

Descriptive Study of Occupational Accidents and their Causes among Electricity Distribution Company Workers at an Eight-year Period in Iran

  • Rahmani, Abdolrasoul;Khadem, Monireh;Madreseh, Elham;Aghaei, Habib-Allah;Raei, Mehdi;Karchani, Mohsen
    • Safety and Health at Work
    • /
    • 제4권3호
    • /
    • pp.160-165
    • /
    • 2013
  • Background: Occupational accidents are unplanned events that cause damage. The socio-economic impacts and human costs of accidents are tremendous around the world. Many fatalities happen every year in workplaces such as electricity distribution companies. Some electrical injuries are electrocution, electric shock, and burns. This study was conducted in an electricity distribution company (with rotational 12-hour shift work) in Iran during an 8-year period to survey descriptive factors of injuries. Methods: Variables collected included accident time, age of injured worker, employment type, work experience, injury cause, educational background, and other information about accidents. Results: Results indicated that most of the accidents occurred in summer, and 51.3% were during shift work. Worker negligence (malpractice) was the cause of 75% of deaths. Type of employment had a significant relationship with type of injuries (p < 0.05). Most injuries were electrical burns. Conclusion: High rate of accidents in summer may be due to the warm weather or insufficient professional skills in seasonal workers. Shift workers are at risk of sleep complaints leading to a high rate of work injuries. Acquiring knowledge about safety was related to job experiences. Temporary workers have no chance to work all year like permanent workers, therefore impressive experiences may be less in them. Because the lack of protective equipment and negligence are main causes of accidents, periodical inspections in workshops are necessary.

기후환경 변화에 따른 전기재해 위험도 분석 (Analysis and Risk Prediction of Electrical Accidents Due to Climate Change)

  • 김완석;김영훈;김재혁;오훈
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.603-610
    • /
    • 2018
  • 본 산업의 발달 및 화석연료 사용 증가로 인하여 지구온난화 및 기후변화가 가속화되어 기존보다 강도 높은 자연재해가 빈번하게 발생하고 있다. 전기시설물은 옥외에 시설된 경우가 많아 자연재해에 큰 영향을 받아 전기설비 관련 사고가 증가하는 추세이다. 본 논문에서는 국내의 기후변화에 따른 전기화재, 감전사고 및 전기설비사고의 통계 현황을 분석하여 기후변화와 연계한 위험도를 제시한다. 또한, 다양한 지역 별(광역시) 기후조건(온도, 습도)과 연계한 전기재해 데이터 분석을 통하여 각 지역의 월별 전기화재 위험도 분석 모델을 제시하고, 저압, 고압 설비의 자연재해에 대한 사고 위험도를 분석한다. 이러한 지역별, 설비별 위험도 분석 모델을 통하여 기초적인 전기재해 예측 모델을 제시하였다. 따라서 제시한 분석 데이터를 활용하여 향후 각 지역 및 전기설비를 대상으로 전기재해 위험도 예측 맵을 웹사이트나 스마트폰 앱을 통하여 전기안전 서비스를 제안할 수 있으며, 기후변화의 따른 자연재해에 대한 전기사고를 미연에 방지하기 위한 내성기준이나 전기설비의 내구성을 증가시키기 위한 노력이 필요하다.

연구실 전기사고방지를 위한 표준체크리스트개발 (Development of a Standard Checklist for Protection to Electrical Accidents of Laboratory)

  • 이동윤
    • 한국콘텐츠학회논문지
    • /
    • 제11권3호
    • /
    • pp.108-115
    • /
    • 2011
  • 대학 연구기관 등의 연구실에서 감전, 전기화재 등 전기사고방지를 위해 수행하는 전기분야 정기점검에 대한 문제점을 파악하고 명확한 기준이 없는 점검항목에 대해 실제 효율적으로 적용 가능하도록 구체적인 기준을 제시한다. 그래서 연구실 전기안전취약요인을 개선하도록 체계적이고 능률적인 정기점검 실시를 위한 표준모델을 마련하고자 한다. 또한, 모든 연구실의 전기안전환경을 중심으로 객관적인 평가가 가능하도록 공통으로 적용될 수 있는 점검항목을 도출하여 연구실 전기안전관리에 부합하도록 연구실 정기점검 전기분야 체크리스트를 개발 한다. 본 연구에서 개발된 전기분야 체크리스트는 실제 필요한 점검 항목에 대한 명확한 기준을 설정하여 모든 연구실에 공통으로 적용할 수 있도록 개발하여 정기점검 수행시 바로 실행 가능하도록 하였다. 이는 연구실의 전기사고 방지를 위한 효율적인 점검뿐만 아니라, 연구실안전수준을 전반적으로 상승시킬 것이다.