• Title/Summary/Keyword: Electric safety

Search Result 1,827, Processing Time 0.026 seconds

A Risk Assessment Approach to Safety Management of Electric Railway Facilities (전기철도 전철전력설비의 위험도 평가 기반 안전관리에 관한 연구)

  • Jang, Yoon-Suk;Choi, Kyu-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.960-967
    • /
    • 2009
  • Power supply system of electric railway has a diversity of safety problems since it should supply high electric power to the trains moving high speed with a lot of passengers on board. This paper provides a risk assessment approach to safety management of the electric railway facilities. Construction of database from field accident information, risk assessment and management of the risk are carried out systematically to ensure the safety. The risk assessment includes hazard identification, cause analysis by FTA(Fault Tree Analysis), consequence analysis by EVA(Event Tree Analysis), and loss analysis. In terms of the severity and the probability of the accidents deduced by these analyses, the risk of the accidents is assessed by using a risk matrix designed for electric railway facilities. Based on the risk assessment, possible risk mitigation options are identified and evaluated by analyzing their impact on the risk reduction and their cost benefit ratio. The long-term safety of the electric railway facilities can be ensured by renewal of the risk assessment and the risk mitigation option analysis with continuous accident database update. The proposed approach is applied to the electric railway facilities of Korean railway based on the accident data from 2002 to 2008.

A study on university students perception of electric kickboard usage environment and safety improvement (일개대학 대학생들이 인지하는 전동킥보드 이용 환경과 안전 개선에 관한 연구)

  • Ho-Young Jin;Seon-Nyeo An;So-Yun Hwang;Jae-Myeong Hyun;Eun-Kyung Jung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.28 no.2
    • /
    • pp.21-31
    • /
    • 2024
  • Purpose: This study aims to examine how college students perceive the usage environment of electric kickboards, recognize safety issues, and seek ways to improve them. Methods: A descriptive survey was conducted on 180 college students from November 1 to November 8, 2023, to analyze the environment and risks associated with using electric kickboards. Results: College students perceived electric kickboards as extremely dangerous. However, they did not receive safety education and 76.4% of the subjects did not wear safety helmets when driving electric kickboards. Women suggested lowering the speed of electric kickboards, including in certain sections, and emphasized that the more accidents they experienced, the more necessary it was to improve regulations. Conclusion: This study comprehensively illustrates the perception of risk and speed improvement among electric kickboard users, and emphasizes the need to prepare detailed guidelines for implementing and operating safety education.

Analysis of the Electric Potential distribution and Evaluation of Electric Shock Risk in Bathtub (욕조에서의 전위분포 해석 및 전격재해 위험성 평가)

  • Kim, Chong-Min;Kim, Han-Sang;Jung, Jong-Wook;Jung, Jin-Soo;Kim, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.37-40
    • /
    • 2006
  • This paper presents the evaluation electric shock risk In bath so that we made and designed a bathtub which is the same size in real public bath. and then we did an experiment, provided of electric leakage in various conditions so, we measured how to form an electric potential and knew the electric potential is formed variously under exposed conductor in bath. also we made certain that electric shock risk is down if we insert an insulated pipe in bathtub pipe which is prevent from being formed the electric field sharply.

  • PDF

Development of Leakage Detector for Electric Equipment Failure in Fountain (분수대에서의 전기설비 고장에 대한 누전 감지 장치 개발)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.35-40
    • /
    • 2018
  • This research aimed to develop an leakage detector of analyzing the electric potential generated from the electric leakage of electric equipment of the fountain. To accomplish this goal, the potential gradient was analyzed against path 1 ~ path 4; this was done by taking the lighting of a fountain as the electric leakage point based on code analyses in Korea and other countries. Lighting 1 was taken as the electric leakage point, and the earthing point was set against lightings(2~3). It appeared that the allowable touch voltage against the 1 type(under 2.5 V) exceeded 60.0%. Therefore, the lighting of fountain turned out to be the most dangerous point, and electric shock could be formed by the electric leakage of electric equipment in underwater as well as by the lighting. An leakage detector was developed based on this risk; this detector is capable of analyzing the electric potential of a electric equipments of the fountain in underwater. Then, a verification test was carried out. This leakage detector can be used to measure electric potential in various submerged areas such as swimming pools, flooded spaces, and fountains.

Safety Diagnosis of Electric Train Driving System Using Vibration Signal (진동신호를 이용한 전기동차 구동장치의 안전성 평가)

  • 이봉현;최연선
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.929-935
    • /
    • 1998
  • Safety diagnosis of electric train driving system is performed using vibration signals of running electric train. Safety diagnosis is tried on the viewpoints of the appreciation of superannuation and the fault diagnosis of motor, reduction gear and bogie. The appreciation of superannuation is checked by the vibration levels of driving parts and the fault diagnosis is done by analyzing the frequencies of the vibration signals which are measured directly from a running electric train. The results shows that the vibration levels of each parts increase as the train gets older and each parts have their own frequency patterns of the vibration. Vibration propagation path is also investigated using calculated the coherence value between bogie and driving system. As the results, it is known that vibration signal can be utilized successfully for the safety diagnosis of the driving part of electric train.

  • PDF

An Assessment of Electric Shock Hazard by Safety Criteria Using Graphical Method (그래프법을 이용한 안전기준에 의한 감전위험성 평가)

  • 김두현;강동규
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.53-60
    • /
    • 2001
  • This paper presents a graphical method for hazard assessment of electric shock by safety criteria. For the human body to be safety actual body current should not exceed safety criteria, i.e. allowable body current. The assessment method presented in this paper is based m the safety criteria of the IEEE Standard 80 as well as the IEC 479-1. The hazard can be assessed in terms of alterable touch voltages instead of alterable body current. Thus, the hazard assessment of given electric shock condition is referred to a procedure by which the actual touch voltages are compared with the allowable (safe) touch voltages. Since the IEC 479-1 safety criteria are nonlinear, the graphical method is presented for the hazard assessment. Body current and body voltage are calculated with the allowable touch voltage. A comparison of the safety criteria of two widely accepted standards, i.e. the IEEE Std 80 End the IEC 479-1 is proposed. Also Thevenin equivalent resistance is obtained from electric shock model expressed by two-port earth-grid-foot system. On the basis of calculated results, the allowable touch voltage, the body current and the body voltage we can conduct the hazard or safety assessment and estimate the severity of electric shock.

  • PDF

REVIEW AND FUTURE ISSUES ON SPENT NUCLEAR FUEL STORAGE

  • Saegusa, T.;Shirai, K.;Arai, T.;Tani, J.;Takeda, H.;Wataru, M.;Sasahara, A.;Winston, P.L.
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.237-248
    • /
    • 2010
  • The safety of metal cask and concrete cask storage technology has been verified by CRIEPI through several research programs on demonstrative testing for the interim storage of spent fuel. The results have been reflected in the safety requirements for dry casks issued by NISA/METI (Nuclear and Industrial Safety Agency, Ministry of Economy, Trade and Industry) of the Japanese government. On top of that, spent fuel integrity has been studied by the Japan Nuclear Energy Safety Organization (JNES). This paper reviews these research programs. Future issues include the long-term integrity of cask components and high burn-up spent fuel.

A Study on the Guidelines for Demand Factor of Electrical Facilities in Subway Stations (지하철 역사전기설비의 수용률 기준설정에 관한 연구)

  • Jang, Su-Yong;Kim, Hak-Lyun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.844-849
    • /
    • 2006
  • The electric facilities for subway stations require reliable and safe electricity in spite of their load increases rapidly. Nevertheless, Korea Electrical Safety Corporation reports that the accidents of independent electric facilities increased greatly from 4,632 cases in 1998 to 6,024 in 1999 and 6,776 cases in 2000, while the ratio of the accidents related with transformers grew gradually. As it is, it is deemed very important to minimize the spreading effects of the electric system accidents and thereby, enhance reliability of the electric supply as well as its safety. According to the fact that the electric facilities for subway stations are important for the public safety and conveniences, it should be careful to set their capacity instead of simply applying the general capacity standard to them, and thereby, improve their economy as well as prevent their accidents. With such a basic conception in mind, this study is aimed at analyzing the characteristics of the electric load in the subway stations and thereupon, suggesting some guidelines for setting of the electric facility capacity for subway stations in terms of optimal operation and safety.

  • PDF

Analysis of Characteristic for Electric Leakage Component at Stable Size (축사 규모별 누전성분 특성 분석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.54-58
    • /
    • 2012
  • This paper is purposed to analyze electric leakage component which can prevent electrical fires on breaker capacity expansion and power failure by operation of ELB(Earth leakage breaker) for stable sizes. In order to analysis for electric leakage component for stable sizes, this paper studied field state investigation which are at stable companies( 10 companies) in cheong-won location to deduce the problems of electric leakage component is analyzed. The field state experiment method is measured with electric leakage component which load part of ELB detected by electric loads(electrical fan, lighting, auto waterer, feeder and halogen lighting) and stable sizes. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in stable.