• Title/Summary/Keyword: Electric field distribution

Search Result 660, Processing Time 0.025 seconds

Overload Criteria of Distribution Transformers Considering the Electric Consumption Patterns of Customers (수용가 전력 소비 패턴을 고려한 배전용 변압기 과부하 판정기준)

  • 윤상윤;김재철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.9
    • /
    • pp.513-520
    • /
    • 2004
  • In the paper, we summarize the result of the experimental research for the overload criteria of domestic distribution transformers considering the electric consumption patterns of customers. For the basic characteristic data of distribution transformer overload, the actual experiments are accomplished. The field data of loads are surveyed from sample transformers for analyzing the consumption pattern of customer load. The load data acquisition devices are equipped, and the algorithm of load pattern classification is applied. In addition to this efforts, various load pattern data. in past are gathered. Then the representative load pattern of each customer type in domestic is extracted. The final results of overload criterions are presented as tabular form through the results of experiments and survey are combined. The field test of the experiment results is peformed using the special manufactured transformers, which can measure both the load and top-oil temperature of transformer. Through this, we verify that the results of field test are similar to the laboratory one and the Proposed overload criteria can be effectively applied to the real system.

Determination of electron energy distribution functions in radio-frequency (RF) and microwave discharges (RF/마이크로웨이브 방전에서의 전자에너지 분포함수의 결정)

  • 고욱희;박인호;김남춘
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.424-430
    • /
    • 2001
  • An electron Boltzmann equation is solved numerically to calculate the electron energy distribution functions in plasma discharge which is generated by radio-frequency (RF) and microwave frequency electric field. The maintenance field strengths are determined self-consistently by solving the homogeneous electron Boltzmann equation in the Lorentz approximation expressed by 2nd order differential equation and an additional particle balance equation expressed by integro-differential equation. By using this numerical code, the electron energy distribution functions in argon discharge are calculated in the range from RF to microwave frequency. The influence of frequency of the HF electric field on the electron energy distribution functions and ionization rate are investigated.

  • PDF

Analysis of Magnetic Field by Catenary Current and Magnetic Field Mitigation in Electric Railway using Passive Loop (가선전류에 의한 자기장 형성과 수동루프를 이용한 전기철도차량내 자기장 유도 감쇄 분석)

  • Yoon, Yeo-Kun;Nah, Wan-Soo;Han, In-Su;Lee, Tae-Hyung;Park, Choon-Soo
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.384-389
    • /
    • 2011
  • The electric railway cars are operated by high voltage supply through the catenary wire. Also, numerous electric equipments operated by electric signal are distributed in the electric railway cars. Such electric equipments are exposed to EMI/EMC problems, and there is the possibility that the magnetic field due to the catenary wire current takes effect on the electromagnetic field in the electric railway cars which move under the catenary wire. There is the possibility that the electromagnetic interference generates in view of the operation of many electric equipments in the electric railway cars. There is the possibility that the communication device faults generate, and that the hazards on the human beings generate. In this paper, we predict the magnetic field around the catenary wire, and obtain the exact magnetic field distribution by comparing the analytic results and the numerical results. Finally, we confirmed the possibility of the passive loop mitigation by comparing the analytic results and the numerical results through the passive loop mitigation technique.

  • PDF

Characteristic Analysis of Spacial Electric Field Distribution in Liquid Crystal of TFT-LCD Panel (3차원 유한요소법을 이용한 TFT-LCD 액정에서의 공간 전기장 분포 특성 분석)

  • Jung, Sang-Sik;Kim, Nam-Kyung;Kim, Dong-Hun;Noh, Min-Ho;Lee, Kyu-Sang
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.3
    • /
    • pp.91-96
    • /
    • 2012
  • In this paper, a three-dimensional finite element model based on the multi-pixel was constructed to accurately predict electric field distributions including an interference phenomenon between adjacent pixels in the liquid crystal of a complicated TFT-LCD panel. Utilizing the elaborate numerical model, the characteristics of spatial electric field distributions depending on various fault-electrode conditions are thoroughly examined on the basis of the field distribution of a normal electrode condition. The validity of the proposed model is proved by comparing the simulation results with those of the existing optical inspection equipments.

Effect of Porcelain/Polymer Interface on the Microstructure, Insulation Characteristics and Electrical Field Distribution of Hybrid Insulators (자기재/폴리머 계면이 하이브리드 애자의 미세구조, 절연특성과 전계분포에 미치는 영향)

  • Cho, Jun-Young;Kim, Woo-Seok;An, Ho-Sung;An, Hee-Sung;Kim, Tae-wan;Lim, Yun-Seog;Bae, Sung-Hwan;Park, Chan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.558-565
    • /
    • 2017
  • Hybrid insulators that have the advantages of both porcelain (high mechanical strength and chemical stability) as well as polymer (light weight and high resistance to pollution) insulators, can be used in place of individual porcelain and polymer insulators that are used for both mechanical support as well as electrical insulation of overhead power transmission lines. The most significant feature of hybrid insulators is the presence of porcelain/polymer interfaces where the porcelain and polymer are physically bonded. Individual porcelain and polymer insulators do not have such porcelain/polymer interfaces. Although the interface is expected to affect the mechanical/electrical properties of the hybrid insulator, systematic studies of the adhesion properties at the porcelain/polymer interface and the effect of the interface on the insulation characteristics and electric field distribution of the hybrid insulator have not been reported. In this study, we fabricated small hybrid insulator specimens with various types of interfaces and investigated the effect of the porcelain/polymer interface on the microstructure, insulating characteristics, and electric field distribution of the hybrid insulators. It was observed that the porcelain/polymer interface of the hybrid insulator does not have a significant effect on the insulating characteristics and electric field distribution, and the hybrid insulator can exhibit electrical insulating properties that are similar or superior to those of individual porcelain and polymer insulators.

A Study on the Current Detector with Non Contact Type (비접촉식 전류 검출 장치에 관한 연구)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.5
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

An Analytical Models for Substrate Current and Gate Current Using Modified Lateral Electric Field Model for Surface-Channel PMOSFET's (수정된 수평 전개 모델을 이용한 SC-PMOSFET의 기판 전류와 게이트 전류의 해석적 모델)

  • 양광선;박종태;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.1
    • /
    • pp.48-53
    • /
    • 1994
  • In this paper, we present the analytical models for substrate current and gate current of stressed SC-PMOSFET using the change of the lateral electric field distribution due to the trapped electron. Calculated Isub and Ig of stressed SC-PMOSFET agree with experimental data. Our model can be very useful explaining the logarithmic time dependence of Isub and Ig. and also the trapped electron distribution.

  • PDF

Applications of an Adaptive Reclosing in Power Distribution Systems (배전시스템에서 적응재폐로방식의 적용에 관한 연구)

  • Rim, Seong-Jeong;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.955-957
    • /
    • 1998
  • This paper presents an adaptive reclosing scheme to improve the reliability in power distribution systems. For an originated faults, this scheme can determine the number of reclosing attempts, so that minimizes the affect of electric facility and customers' load. To verify the effectiveness of the proposed scheme. numerical simulation which calculates a various indices to consider the reliability and the effect of electric facility, is carried out with actual field data. Results show that the proposed scheme can be applicable to field operation.

  • PDF

Variation of the Representation Ellipsoid for Refractive Index of Bi12GeO20Single Crystal by an Electric Field (전기장에 의한 Bi12GeO20 단결정의 굴절률 표시타원체의 변형)

  • Lee, Su-Dae;Lee, Chan-Ku
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.89-95
    • /
    • 2005
  • We derived a formula which can calculate the space distribution of refractive index variation by an applied electric field about Bi$_{12}$ GeO$_{20}$ single crystal. Stereographic projection maps of refractive index variation by an applied electric field were made out using numerical value to be calculated by this formula. By the calculated results, since an electric field had applied to [(equation omitted) 1 1] direction and [1 (equation omitted) 1] direction of Bi$_{12}$ GeO$_{20}$ crystal, positive variation of the refractive index of [(equation omitted) 1 1] direction and [1 (equation omitted) 1] direction was the largest. The incremented refractive index per unit electric field was +3.2410${\times}$10$^{-11}$ V$^{-1}$ for the wavelength of 6328 $\AA$. Since an electric field had applied to [1 1 1] direction and [(equation omitted) 1] direction, negative variation of the refractive index of [1 1 1] direction and [(equation omitted) 1] direction was the largest. The decremented refractive index per unit electric field was -3.2410${\times}$10$^{-11}$ V$^{-1}$ for the wavelength of 6328 $\AA$.