• 제목/요약/키워드: Electric fan

검색결과 180건 처리시간 0.022초

Lifting Fan의 위치가 복합형 UAM의 공력특성에 미치는 영향 (Analysis with Lifting Fan Position of Hybrid UAM Aerodynamic Characteristics)

  • 이수현;조환기;임동균
    • 한국항공운항학회지
    • /
    • 제30권2호
    • /
    • pp.1-6
    • /
    • 2022
  • Recently, the development of UAM, which was named by NASA as an alternative to solve the traffic and environmental problems caused by the rapidly progressing urbanization. When designing UAM, the location of lift fans greatly affects the core technology of the eVTOL type, distributed electric propulsion technology and aerodynamic performance of the vehicle. In this paper, a hybrid UAM model was designed using OpenVSP, an open source aircraft configuration modeling program, and aerodynamic analysis was performed according to the lift fans position change by the vortex lattice method. As a result, it is confirmed that the flight parameters and trailing wakes are stable by fixing the lift fan with the state rotated 0° to the flow direction of the aircraft during cruise flight. Also, OpenVSP is a suitable tool to be used in aircraft configuration modeling and design.

여름철 환경에서 팬이 있는 조끼의 인체 착용 효과 (Analysis of the Effects of Vests with Fan in Summer Environments)

  • 엄란이;이예진
    • 한국의류학회지
    • /
    • 제43권6호
    • /
    • pp.856-865
    • /
    • 2019
  • This study analyzed the effect of wearing a vest with an attached electric fan. Korean men in their 20s were given test "fan vests" equipped with fans on the chest, stomach, upper back, or lower back to wear. Participants wore them in a climate chamber set to replicate a summer environment (30±3℃, 75±1%RH, 0.2 m/sec). Subjective sensations and surface temperatures were measured. The attached fan on the front of the vest lowered the temperature of the vest and the skin surface where the fan was positioned, regardless of whether the wearer engaged in exercise. However, a fan attached to the lower back of the vest was effective in lowering the lower back of the vest as well as the upper back, back of the arm, and back of the neck. In addition, subjective evaluations indicated that a vest with fans attached to the stomach and lower back provided a cool sensation. However, it was confirmed that the design of an auxiliary tool capable of dispersing the weight is necessary since the weight of the fans can interfere with the comfort of wearing the vest.

수치적 방법을 이용한 저소음 얼터네이터 냉각팬의 개발 및 소음 특성 분석 (Development and Analysis on Noise Characteristics of Low Noise Cooling Fan for an Alternator by Using Numerical Method)

  • 김욱;전완호;현재진;임철구;이성하
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.608-609
    • /
    • 2008
  • An alternator which converts mechanical rotating energy into electric energy is an important component of a vehicle. It operates in broad range from 3000 RPM to 18000 RPM. So, sufficient flow rate and low noise are needed in such broad operating range for a cooling fan of this alternator. In current study, the cooling fan of an alternator is developed through DFSS process and numerical analysis. In order to calculate flow rate and noise level, SC/Tetra and FlowNoise S/W are used respectively, for a new developed fan, compared with original model, numerical result shows 3 dBA reduction and measured value shows 4 dBA reduction.

  • PDF

수치기법을 이용한 저소음 얼터네이터 냉각팬의 DFSS 최적 설계 (DFSS OPTIMUM DESIGN OF LOW NOISE COOLING FAN FOR AN ALTERNATOR BY NUMERICAL METHOD)

  • 김욱;전완호;현재진;임철구;이성하
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.233-238
    • /
    • 2008
  • An alternator which converts mechanical rotating energy into electric energy is an important component of a vehicle. It operates in broad range from 3000 RPM to 18000 RPM. So, sufficient flow rate and low noise are needed in such broad operating range for a cooling fan of this alternator. In current study, the cooling fan of an alternator is developed through DFSS process and numerical analysis. In order to calculate flow rate and noise level, SC/Tetra and Flow Noise are used respectively, for a new developed fan, compared with original model, numerical result shows 3 dBA reduction and measured value shows 4 dBA reduction.

  • PDF

수치기법을 이용한 저소음 얼터네이터 냉각팬의 DFSS 최적 설계 (DFSS OPTIMUM DESIGN OF LOW NOISE COOLING FAN FOR AN ALTERNATOR BY NUMERICAL METHOD)

  • 김욱;전완호;현재진;임철구;이성하
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.233-238
    • /
    • 2008
  • An alternator which converts mechanical rotating energy into electric energy is an important component of a vehicle. It operates in broad range from 3000 RPM to 18000 RPM. So, sufficient flow rate and low noise are needed in such broad operating range for a cooling fan of this alternator. In current study, the cooling fan of an alternator is developed through DFSS process and numerical analysis. In order to calculate flow rate and noise level, SC/Tetra and Flow Noise are used respectively, for a new developed fan, compared with original model, numerical result shows 3 dBA reduction and measured value shows 4 dBA reduction.

  • PDF

진공청소기 원심 홴의 소음원 분석 및 공력 소음 예측 (Investigation of the noise sources for the centrifugal fan and aeroacoustic noise prediction)

  • 정예은;배영민;문영준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.645-645
    • /
    • 2009
  • In many practical applications of the centrifugal fan, the impeller-diffuser interaction noise is considered as a main source of fan noise. The housing for an electric motor is also expected to play an important role on noise propagation because of its complicated configuration. This study investigates the impeller-diffuser interaction noise and its sources by computing three-dimensional, incompressible flow field of the centrifugal fan in motor housing. The effect of motor case on fan noise characteristic is then investigated using the Brinkman penalization method, while the noise source associated with impeller-diffuser interaction is mathematically modeled. It is found that the present methodology combined with mathematical description of noise source provides a fairly good agreement with the experimental results, indicating that the motor housing has significant effect on noise characteristics. Finally, aeroacoustic noise prediction for various impeller-diffuser blade count ratios is conducted for noise reduction.

  • PDF

A New Blade Profile for Bidirectional Flow Properly Applicable to a Two-stage Jet Fan

  • Nishi, Michihiro;Liu, Shuhong;Yoshida, Kouichi;Okamoto, Minoru;Nakayama, Hiroyasu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.449-455
    • /
    • 2009
  • A reversible axial flow fan called jet fan has been widely used for longitudinal ventilation in road tunnels to secure a safe and comfortable environment cost-effectively. As shifting the flow direction is usually made by only switching the rotational direction of an electric motor due to heavy duty, rotor blades having identical aerodynamic performance for bidirectional flow should be necessary. However, such aerodynamically desirable blades haven't been developed sufficiently, since most of the related studies have been done from the viewpoint of unidirectional flow. In the present paper, we demonstrate a method to profile the blade section suitable for bidirectional flow, which is validated by studying the aerodynamic performances of rotor blades of a two-stage jet fan experimentally and numerically.

ATmega128 마이크로 컨트롤러를 사용한 스마트 선풍기 속도제어 (Speed Control of Smart Electric Fan using ATmega128 Microcontroller)

  • 원재혁;김정운;이성준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.281-283
    • /
    • 2009
  • This paper presents the smart fan which is operated by a small conventional motor and an ultrasonic sensor. The smart fan generates cool wind with regulated speed of wing by the distance between the user and the fan. In this research, an 8-bit microcontroller (ATmega128) and an ultrasonic sensor (NT-TS601) are utilized for the system control and sensing information. In order to obtain the speed information from the encoderless DC motor, a stroboscope is used, which provides the voltage variation by the motor speed. The proposed smart fan makes the user feel cool, convenient and safe at a low cost.

  • PDF

2단 축류홴과 엇회전식 축류홴의 공력특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Two-Stage and a Counter-Rotating Axial Flow Fan)

  • 조진수;조이상
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1281-1292
    • /
    • 2001
  • Experiments were done for the comparison of performance and flow characteristics between a two -stage axial flow fan and a counter-rotating axial flow fan. Each stage of the two -stage axial flow fan used fur the present study has an eight bladed rotor and thirteen slater blades. The front and the rear rotor of the counter - rotating axial flow fan have eight blades each and are driven by coaxial counter ro latins shafts through a gearbox located between the rear rotor and the electric motor. Both of the two axial fan configurations have identical rotor blades and the same operating condition fur the one -to-one comparison of the two. Performance curves of the two configurations were obtained and compared by varying the blade pitch angles and axial gaps between the blade rows. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fa n flow characteristics were measured using a five-hole probe by a non-nulling method. The velocity profiles between the hub and tip of the fans were measured and analyzed at the particular operating condition s of peak efficiency, minimum and maximum pressure coefficients. The peak efficiency of the counter-rotating axial fan was improved about 2% respectively, compared with the two stage axial fan. At the minimum pressure coefficient point of the two stage axial fan, the fan inlet flow patterns show that axial velocity highly decreased in the vicinity of the blade tip region. Also, the reverse flow took place at the blade tip.

발전소 대용량 FD Fan 전동기의 교류 가변속 장치 (VVVF) 적용에 관한 연구 (Research Study on the Application of AC Adjustable speed Drive for FD Fan Motor in power plant.)

  • 허성광;류홍우;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1203-1205
    • /
    • 1992
  • Due to poor energy resources, the importance of energy saving has been greatly emphasized. It can be one method of energy saving to reduce the power. The AC adjustable speed drive systems show excellent efficiency, which have been developed in recent years. The adjustable speed drive system improves the efficiency in lightly load condition and extend the life span of motor by limiting the over-current at starting. The main topic of study is the results of energy saving and emergency transfer.

  • PDF