• Title/Summary/Keyword: Electric discharge lamp

Search Result 56, Processing Time 0.022 seconds

The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp (고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지)

  • Han, Tae-Hwan;Woo, Chun-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.148-151
    • /
    • 2004
  • For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.

The Algorithm of Life Time Diagnostics end Evaluating of Exchanges Time about High Pressure Sodium Vapor Lamp Using the LabVIEW Software Package (LabVIEW 소프트웨어 패키지를 이용한 고압나트륨전등의 교환시점 및 수명진단 알고리듬)

  • Han, Tae-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.1-7
    • /
    • 2004
  • It is necessary for starting voltage to him on high pressure discharge lamp. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in Electric discharge tube, So accelerative electron collide against vapour atom and second electron is generated, And rapidly the current flow to Electric discharge tube. This paper showed that the life cycle and exchanges time for all electric discharge lamp was different according to each manufactures, This paper is proposed the evaluating algorithm of exchanges time for high pressure sodium vapor lamp, used LabVIEW software package.

Pulse Density Modulated ZVS High Frequency Inverter with Reverse Blocking Single Switch for Dielectric Barrier Discharge Lamp Dimming

  • Sugimura Hisayuki;Yasui Kenji;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.206-209
    • /
    • 2006
  • At present, the cold cathode fluorescent lamp (CCFL) using mercury lamp has been generally used far liquid crystal backlight source of personal computer and car navigation and so on. This kind of lamp is more excellent on luminance performance and cost. However, the requirements of liquid crystal backlight due to a light source without mercury have been strongly increased from a viewpoint of the actual influence on environmental preservation and environmental recycling. As fluorescent lamp without mercury, Dielectric Barrier Discharge based rare gas fluorescent lamp (DBD-FL) using xenon (Xe) gas has been studied so far. This DBD lamp has no influence on the human body and environmental recycle. Its operating life is long because electrode is out. In this paper, the simulation and experimental results of soft switching high frequency inverter with reverse blocking single switch as a high frequency power supply circuit for DBD-FL using Xe gas are comparatively evaluated and discussed from a practical point of view.

  • PDF

Discharge Characteristic of Surface Type FFL as LCD Backlighting according to Dielectric Layer (LCD 후면광원용 면방전형 FFL의 Dielectric Layer에 따른 방전 특성)

  • 임민수;정득영;윤성현;임기조;권순석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.177-180
    • /
    • 1999
  • In this paper, we studied Surface Discharge Type Flat Fluorescent Lamp(FFL) with High Luminance for LCD Backlighting. This lamp is Surface Discharge Type structure with a pair of Sodalime glass, insulator layer, phosphor layer, and Xe gas gap. There are two influences of Electric field on different dielectric thickness. The Electric field difference at the dielectric layer itself enhances minimum value of firing voltage and luminance uniformity. So, we measured the Electric filed at 0.5mm, 1mm gap length and discharge voltage for difference dielectric layer thickness. In experiment result, the thicker dielectric layer has higher firing voltage and lower current.

  • PDF

The analysis of neutral particle in Mercury discharge lamp

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2421-2423
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm $(6^3S_1{\rightarrow }6^3P_2)$ were larger than 404.8nm $(6^3S_1{\rightarrow}6^3P_1)$. According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

The optical analysis of discharge lamp by Laser

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.570-571
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1\rightarrow6^3P_2$) were larger than 404.8nm ($6^3S_1\rightarrow6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the L1F signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

Discharge characteristics of FFL as applied voltage variation (인가 전압의 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.379-382
    • /
    • 2000
  • The characteristics of Xe discharge lamp(Mercuryless lamp) are described in this paper. In this paper, FFL is operated by sine wave and pulsed source. We apply V-Q Lissajous' figure for the discharge measurements of FFL which has the electrodes covered with dielectric. When FFL is operated by sine wave source, the characteristics are similar to DBD(Dielectric Barrier Discharge) and SD(Silent Discharge). And we compared the characteristics of FFL which is operated with sine wave and pulsed discharge by using V-Q Lissajous' figure method. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. As the duty ratio increases the electric field becomes strong and much more xenon ions are produced. And the number of metastable xenon atoms seem to increase, therefore, the phosphor radiation after the cut off of voltage increases compared with the first peak of radiation. Consequently, the 172㎚ radiation becomes strong as the duty ratio increases.

  • PDF

A Study of Characteristic of Oriental Herbal Medicine Storage System using Ozone Lamp (오존램프를 이용한 한약재 저장 장치의 특성 연구)

  • Woo, Sung-Hun;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.98-103
    • /
    • 2007
  • We made a oriental herbal medicine storage system and studied a preservation characteristic of oriental herbal medicine in this research. The lamp(OZ-Lamp) in a storage system is the low pressure ultraviolet lamp which radiates the sterilizing and ozonic rays. We made research ozone generation and electric discharge characteristic of a oriental herbal medicine storage system, which have radiation feature of ultraviolet rays of a short wavelength to be happened in the electric discharge. Also, we made research an ingredient and quality characteristic of oriental herbal medicine according to ozone treatment storage.

A PSpice Model for the Electrical Ballast of HID Lamps (전자식 안정기를 위한 HID Lamp 시뮬레이션 모델)

  • 지윤근;김남준
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.1
    • /
    • pp.27-32
    • /
    • 2003
  • The thesis is used by PSpice circuit model to the characteristics of a fluorescent lamp modified form of he classical Cassie and Mayr equations in order to show the characteristics of HID(High-Intensity Discharge) Lamp. This is useful for applying high-frequency electric ballast for HID Lamp, and show that the result of experimentations and simulations, such as lamp rating, input voltage, high-frequency electric ballast which is using the ABM circuit model of the low pressure sodium lamp, come to the voltage and current wave.

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF