• Title/Summary/Keyword: Electric conductivity balance

Search Result 17, Processing Time 0.019 seconds

Interpretation of Analytical Data of Ion Components in Precipitation, Seoul (서울 地域 降水中 이온成分 分析資料의 解析)

  • 강공언;이주희;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.323-332
    • /
    • 1996
  • Precipitation samples were collected by the wet-only sampling method at Seoul from September 1993 to June 1995. Sample were analysed for the anions $(NO_3^-, NO_2^-, SO_4^{2-}, Cl^-, and F^-)$ and cations $(Na^+, K^+, Ca^{2+}, Mg^{2+}, and NH_4^+)$ in addition to pH and electric conductivity. In order to establish the chemical analysis data of high quality, the assurance checks for analytical data of precipitation were performed by considering the ion balance and by comparing the measured conductivity with the calculated conductivity. As we applied the various assurance checking methods by the ion balance used until recently to a data set measured in this study, the f value expressed as $\Sigma C/\Sigma A$ was found to be not appropriate for the data screening. Also, the scattering plot between cations and anions in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a data set of samples of various concentration levels. The h value defined as (A-C)/C for C $\geq$ A and (A-C)/A for C < A was used to check the ion balance. However, the standard of data screening by h value must very in response to total ion concentration of samples. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance of evaluating by h value and the conductivity balance. Further the quality control was achieved by these quality assurance methods. As the result, 67 samples among total 77 were obtained as valid. As the central tendency value for a statistical summary in the analytical parametr of samples, the volume-weighted mean value was found to represent more the general chemistry of precipitation rather than the arithmetic mean. The volume-weighted mean pH was 5.0 and 25% of samples was less than this mean. The concentrations of sufate and nitrate in precipitation were 90.4 ueq/L and 32.4 ueq/L which made up 59% and 21% of all anions. The raion of $SO_4^{2-}/(NO_3^- + NO_2^-)$ in precipitation was 2.7, which indicates that the contributions of $H_2SO_4$ and $HNO_3$ to the acidity of precipitation are 70% and 30%, respectively.

  • PDF

Water Balance Evaluation of Final Closure Cover for Near- surface Radioactive Wastes Disposal Facility

  • Keunmoo Chang;Park, Joo-Wan;Yoon, Jeong-Hyoun;Park, Heui-Joo;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.274-282
    • /
    • 2000
  • The simulation of water balance was conducted for suggested four alternative multi-layer cover design of near-surface radioactive waste disposal facility under domestic climate condition. The analysis was also conducted for the most favorable one out of four alternative cover design under conservative scenarios. Until 100 years after closure of disposal vault, the infiltration flux for the most favorable cover design was negligible even under doubling of the ambient precipitation condition. When the degradation of asphalt and geomembrane after 100 years of closure was considered, the infiltration flux significantly increased almost to the design criteria of cover system in I' Aube disposal facility. And it was found that the hydraulic conductivity of bentonite/sand as a bottom barrier should be no greater than 1$\times$10$^{-7}$ cm/sec recommended by U.S. EPA.

  • PDF

The Study on the Power Consumption for Glass Melting by Cold Crucible Melter (CCM용융에 대한 유리용융 조건 연구)

  • Jin, Hyun-Joo;Lee, Kyu-Ho;Jung, Young-Jae;Bae, So-Young;Kim, Tae-Ho;Jung, Young-Joon;Kim, Young-Seok;Lee, Kang-Taek;Ryu, Bong-Ki
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.2
    • /
    • pp.65-68
    • /
    • 2008
  • Generally CCM (cold crucible melting) is not suitable for melting glass. However, in this study we described the quantitative relationship between the basic property of glass and power balance, the power absorption in the melt, the losses in the coil and the cold crucible, for melting glass in CCM. The dependence of power balance on the applied frequency and the electric conductivity has been found. Above 300 kHz, the glass (B) contained alkali ion which has the low resistance $3.0{\Omega}{\cdot}cm$ at $900^{\circ}C$ and $1.36{\Omega}{\cdot}cm$ at $1,100^{\circ}C$ was melted easily and 60% of the overall power was absorbed in the melt and 30% and 10% of the overall power was lost in the cold crucible and coil respectively. Under the same condition, the glass (A) contained non-alkali ion was not melted easily and 50% of the overall power was absorbed in the melt and 40% and 10% of the overall power was lost in the cold crucible and coil respectively. In conclusion, the small absorbed power of the overall power in melt prevented a successful melting as for glass A, and the successful melting depends on the relative size of the absorbed power in melt irrespective of the melting volume. Hence, as typical for direct induction heating method(CCM), the successful melting strongly depended on the chosen working frequency based on electric conductivity of glass, power balance and the control of the critical power which was absorbed in melt.

Acidity and Chemical Composition of Precipitation at Background Area of the Korean Peninsula (Anmyeon, Uljin, Gosan) (한반도 배경지역 (안면, 울진, 고산) 상수의 산성도와 화학특성)

  • Kim, Sang-Baek;Choi, Byoung-Cheol;Oh, Suk-Yeong;Kim, San;Kang, Gong-Unn
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.15-24
    • /
    • 2006
  • Precipitation samples were collected at Anmyeon (1997 - 2004), Uljin, and Gosan (1998 ~ 2004), the background area of the Korean Peninsula. These samples were analyzed for the concentration of 9 major ionic components ($F^{-}$,$Cl^{-}$, $NO_{3}^{-}$, $SO_{4}^{2-}$, $Na^{+}$, $NH_{4}^{+}$, $K^{+}$, $Mg^{2+}$, $Ca^{2+}$) with including a pH and an electric conductivity. Data quality for these samples was verified by ion balance and conductivity balance which are based on GAW manual for precipitation chemistry and the number of valid data at Anmyeon, Uljin, and Gosan is 249, 173, and 188, respectively. During the study period, the precipitation-weighted average pH at Anmyeon, Uljin, and Gosan was found to be 4.81, 4.87 and 4.89, respectively and each annual average pH was showed below pH 5.6 for every site. From the frequency survey on the precipitation acidity, the occurrence rate of acid rain below pH 5.6 is greater than $80\%$ for every site. Particularly, the highest occurrence rate for strong acid rain below pH 4.5 was found at Anmyeon, $32.1\%$, compared with other sites ($10.4\%$ at Uljin, $15.4\%$ at Gosan). That's because acidifying species (nss-$SO_{4}^{2-}$, $NO_{3}^{-}$) are remarkably high concentration at Anmyeon.

A Preliminary Conductivity Model Experiment for Determining Hydraulic Constants in Physical Model Borehole (시추공 수리전도도 상수를 결정하기 위한 전기전도도검층 기법을 이용한 예비모형실험)

  • 김영화;임헌태
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.1
    • /
    • pp.48-56
    • /
    • 2003
  • A geophysical conductivity logging technique has been adopted to determine hydraulic constants using a simplified physical model that depicts the borehole condition. An experiment has been made by monitoring the conductivity change within the model hole using borehole environment water and incoming-outgoing water of different salinity, under the state of constant flow rate by maintaining balance between inflow and outflow. Conductivity variation features were observed that depended on flow rate, salinity contrasts between fluid within the hole and incoming-outgoing fluid, and density contrasts between fluid conductivity within the hole and incoming fluid. The results of the experiment show the uniform change of fluid conductivity within the hole with time, a fairly good correlation between the flow rate and the conductivity change rate. The geophysical conductivity logging technique can be an efficient tool for determining hydraulic constants if the model equation is verified by henceforward experiments.

Chemical Composition of Rainwater in Taean Area (태안지역 빗물의 화학적 특성)

  • Lee, Jong-Sik;Jung, Yee-Keun;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.3
    • /
    • pp.204-208
    • /
    • 1999
  • This study was carried out to investigate the chemical properties of rainwater in Taean area. The rainwater way collected for six months from May to Octotber in 1998, and analyzed its chemical composition. The ion balance and electric conductivity balance showed confidence to chemical analyses of rainwater. Distribution rates of pH of rainwater in Taean area were 43% and 38% in the range of pH $4.5{\sim}5.0$ and $5.0{\sim}5.6$, respectively. Among the 1mm fraction for initial 5mm of rainfall, ion concentration of initial rainwater (less than 1mm of rain) was higher than those of the later terms. The major ions in rainwater were $NH_4\;^+$ and $Ca_2\;^+$ for cations, and $SO_4\;^{2-}$ and $NO_3\;^-$ for anions. The pH value of rainwater showed the lowest level of 4.3 in August. The ratio of non-sea salt $SO_4\;^{2-}$ to $NO_3\;^-$ was 2.4.

  • PDF

Optimum Curing and Full-out Velocity in the Rubber Extrusion Process for Electric Cable Manufacture (전선피복용 고무압출가공 공정의 최적 경화 및 선출 속도)

  • Kim, Duk-Joon;Choi, Sang-Soon;Kim, Tae-Ho
    • Elastomers and Composites
    • /
    • v.33 no.2
    • /
    • pp.93-102
    • /
    • 1998
  • In electric cable industries, the curing extent of the rubber materials covering the electric cores gives an significant effect on their final performance. The curing extent of rubber is controlled mostly by pull-out velocity of cable in the extrusion process. The final curing extent may be different for different radial positions inside the rubber because of the non-uniform temperature distributions during the curing process. In this contribution, the prediction of curing extent distribution throughout the radial direction of rubber is represented when the cable is passing through the steam curing zone with a fixed pull-out velocity. The prediction of the optimum pull-out velocity for the desired curing extent distribution is also reported. The steady-state heat balance was developed for the curing and cooling processes in which the pull-out rubber was cured by high temperature steam and then cooled by ambient water. A few essential material properties such as density, specific heat, and thermal conductivity were measured to analyze the temperature distribution during the curing and cooling processes. The times to reach 90% curing extent at varying temperatures were measured and used to determine the final cure extent distribution inside the rubber.

  • PDF

Nanostructured Polymer Electrolytes for Li-Batteries and Fuel Cells

  • Park, Mun-Jeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.71.2-71.2
    • /
    • 2012
  • There are rising demands for developing more efficient energy materials to stem the depletion of fossil fuels, which have prompted significant research efforts on proton exchange fuel cells (PEFCs) and lithium ion batteries (LIBs). To date, both PEFCs and LIBs are being widely developed to power small electronics, however, their utilization to medium-large sized electric power resources such as vehicle and stationary energy storage systems still appears distant. These technologies increasingly rely upon polymer electrolyte membranes (PEMs) that transport ions from the anode to the cathode to balance the flow of electrons in an external circuit, and therefore play a central role in determining the efficiency of the devices; as ion transport is a kinetic bottleneck compared to electrical conductivity, enormous efforts have been devoted to improving the transport properties of PEMs. In present study, we carried out an in-depth analysis of the morphology effects on transport properties of PEMs. How parameters such as self-assembled nanostructures, domain sizes, and domain orientations affect conductivities of PEMs will be presented.

  • PDF

Evaluation of Life Span for Al2O3 Nano Tube Formed by Anodizing with Current Density

  • Lee, Seung-Jun;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.148-148
    • /
    • 2017
  • Surface modification is a type of mechanical manipulation skills to achieve extensive aims including corrosion control, exterior appearance, abrasion resistance, electrical insulation and electrical conductivity of substrate materials by generating a protective surface using electrical, physical and chemical treatment on the surface of parts made from metallic materials. Such surface modification includes plating, anodizing, chemical conversion treatment, painting, lining, coating and surface hardening; this study conducted cavitation experiment to assess improvement of durability using anodizing. In order to observe surface characteristics with applied current density, the electrolyte temperature, concentration was maintained at constant condition. To prevent hindrance of stable growth of oxide layer due to local temperature increase during the experiment, stirring was maintained at constant speed. In addition, using galvanostatic method, it was maintained at processing time of 40minutes for 10 to $30mA/cm^2$. The cavitation experiment was carried out with an ultra sonic vibratory apparatus using piezo-electric effect with modified ASTM-G32. The peak-to-peak amplitude was $30{\mu}m$ and the distance between the horn tip and specimen was 1mm. The specimen after the experiment was cleaned in an ultrasonic bath, dried in a vacuum oven for more than 24 hours, and weighed with an electric balance. The surface damage morphology was observed with 3D analysis microscope. As a result of the study, differences were observed surface hardness and anti-cavitation characteristics depending on the development of oxide film with the anodizing process time.

  • PDF

Development and Performance Evaluation of Aerosol Generator of MWCNTs for Inhalation Toxicology (흡입 독성 평가를 위한 다중벽 탄소나노튜브의 에어로졸 발생장치 개발 및 성능 평가)

  • Lee, Gun-Ho;Jeon, Ki Soo;Yu, Il Je;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.231-238
    • /
    • 2013
  • Carbon nanotubes (CNTs) are one of the nanomaterials that were discovered by Iijima in 1991 for the first time. CNTs have long cylindrical and axi-symmetric structures. CNTs are made by rolling graphene sheets. Because of their large length-to-diameter ratio, they are called nanotubes. CNTs are categorized as single-walled carbon nanotubes (SWCNTs) or multi-walled carbon nanotubes (MWCNTs) based on the shell structures. CNTs are broadly used in various fields, such as scanning probe microscopy, ultra fine nano balance and medicine, due to their extraordinary thermal conductivity, electrical and mechanical properties. Because long, straight CNTs have the same shape as asbestos, which cause cancer in cells lining the lung, there have been many studies on the effects of MWCNTs on human health that have been conducted. Stable atomization of CNTs is very important for the estimation of inhalation toxicity. In the present study, electro-static assisted axial atomizer (EAAA), which is the instrument that uses MWCNTs and aerosolizes them by transforming the single fiber shape using ultrasonic dispersion and electric field, was invented. EAAA consists of a ultrasonic bath for dispersion of MWCNTs and a particle generator for atomizing single fibers. The performance evaluation was conducted in order to assess the possibilities of 6-hour straight atomization with stability, which is the suggested exposure time in a day for the estimation of inhalation toxicity.