• 제목/요약/키워드: Electric and Magnetic Field

검색결과 767건 처리시간 0.027초

비접촉식 전류 검출 장치에 관한 연구 (A Study on the Current Detector with Non Contact Type)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 추계학술대회
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

과전류 계측을 위한 광자계센서의 구현 (Implementation of Optical Magnetic Field Sensor for Measurement of Over Current)

  • 박해수;노종대;김요희;박병석;안성준;조홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1871-1873
    • /
    • 1997
  • The conventional current transformers are often take faults and out of order that for detect to over current of electric power lines because electromagnetic interference. But, it is possible to implement protection relay of high reliability using optical magnetic field sensor which are immunity and small size. The optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. And it is not necessary to make with capacitance of electric power lines as optical magnetic field sensor is have linearity from 0 to about 20kA. In this study, we designed and constructed compensative feedback circuit in order to minimize of optical power intensity variation with environ- mental variations(temperature, drive current) of light source. And this system have highest optical advantages and reliability.

  • PDF

의료영상장치의 전자파 안전에 대한 연구 (A Study on the Safety of Electromagnetic Wave of Medical Imaging System)

  • 선종률;이원정;임재동
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

외부 자계 인가에 따른 고온초전도 케이블 도체의 ?치 특성 (Influence of external magnetic field on HTS cable conductor)

  • Seong Woo Yim;Si Dole Hwang;Je Myoung Oh;Byung Sung Han
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.284-287
    • /
    • 2003
  • Quench characteristics of HTS cable conductor due to external magnetic field were investigated. Firstly, the influence of critical characteristics of HTS tape on locally applied magnetic field was examined. Secondly, critical current of HTS tapes, which are wound on surface of former, were measured respectively, before the experiment for quench characteristics, Finally, 50mT and 100mT were applied to HTS cable conductor and quench characteristics were investigated through V-I curves. As the results, same as the result of HTS tape, HTS cable conductor showed strong dependence on external magnetic field with direction and magnitude.

  • PDF

송전선로의 전자계 크기 측정 및 분석 (Measurement and Analysis of Electric and Magnetic Fields Near Overhead Transmission Lines)

  • 김상범;조성배;신구용;이동일;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1908-1910
    • /
    • 1997
  • The electric and magnetic fields (EMFs) near 345/154 kV overhead transmission lines were measured. The average values of maximum electric field and magnetic field for 44 transmission lines were 1.11 kV/m and 24.5 mG, respectively. These values were lower than any standards of advanced countries. The EMFs of distribution lines and substation, and electric appliances were also measured and compared with those of transmission lines.

  • PDF

Estimation of Output Voltage and Magnetic Flux Density for a Wireless Charging System with Different Magnetic Core Properties

  • Park, Ji Hea;Kim, Sang Woo
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.105-110
    • /
    • 2013
  • The design model and key parameters of the material design for the control of induced magnetic flux at the near-field and efficient power transfer in a modified wireless power transfer (WPT) system with a large air gap of wireless electric vehicles were investigated through analytical simulations for magnetic vector and time-domain transient analysis. Higher saturation magnetic core with low core loss induced a stronger vertical magnetic field by the W-type primary coil in the WPT system with a gap of 20 cm at 20 kHz, which is shown from the vector potentials of the magnetic induction. The transient analysis shows that the higher magnetic fluxes through the pick-up cores lead to a linear increment of the alternating voltage with a sinusoidal waveform in the non-contact energy transfer system.

영구자석조합형 축방향 자기베어링 시뮬레이션 및 실험 (Permanent Magnet Combined Thrust Magnetic Bearing Simulation and Experiment)

  • 박병철;정세용;한상철;이정필;한영희;박병준
    • Tribology and Lubricants
    • /
    • 제27권3호
    • /
    • pp.167-173
    • /
    • 2011
  • In this paper, an actuator model of the thrust magnetic bearing for the flywheel energy storage is derived using magnetic circuit theory. And we compared this result with finite element magnetic field analysis result. Based on the actuator model, we made a simulation model of the thrust magnetic bearing system. We showed the closed loop transfer function and sensitivity function of the thrust magnetic bearing system using both the simulation model and the experiment. The experimental result at rotation velocity 18,000rpm of thrust magnetic bearing system is included.

통계적방법을 이용한 초고압 송전선의 전자계 특성 및 인체 안전에 관한 연구 (A Study on Characteristics and Safety for Human Body in ELF Electric and Magnetic Fields using Statistical Method)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.75-80
    • /
    • 1996
  • This paper presents a study on characteristics and safety for human body in ELF electric and magnetic fields using statistical method. The magnetic fields from a power line can be computed given a knowledge of the currents, voltage and geometry of the line. In this paper, a statistical method for predicting the magnetic fields given the inherent indetermination of the currents is presented. But the electric field is calculated given a knowledge of the voltage and geometry of the line. The effect of unexpected fluctuations in current is modeled by the Monte Carlo simulation. The suggested method is applied to the 345kV and 765kV transmission line system, the result shows that the maximum electric and magnetic field intensity is 6.8627kV/m and 284mG in 345kV system, 2. 5590kV/m and 35mG in 765kV system, respectively.

  • PDF

345/154KV 전력소 구내의 자계 분포 특성 (Characteristic of Magnetic Fields Distribution in 345/154KV outdoor Substation)

  • 사재원;김성명;홍정표;전형태;한성진;주수원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.97-99
    • /
    • 1997
  • For two decades and more, a lot of research work on the biological effects of EMF (Electromagnetic Field) on human health have been reported. Electric facilities in a typical substation are the main source of magnetic field. This paper presents the measurement and analysis of magnetic field in 345/154KV outdoor substation. The magnetic field depends on the currents which distributed by electric facilities. The result of this paper will be able to be used as basic informations to reduce the level of EMF from the electric utility facilities.

  • PDF