전력구 내 전자기파에 대한 작업 환경 측정 (The Measurement of Electromagnetic Wave in Power Cable Tunnel of Underground Utility Tunnel)

  • 강대곤;박재학
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Electromagnetic measurements of the power cable tunnel were conducted from August 10 to 20, 2018, in the ${\bigcirc}{\bigcirc}$ city underground utility tunnel. During this period, the average temperature was $31.89^{\circ}C$ and the humidity was 67.56% in power cable tunnel. As a result of the electromagnetic measurement, the highest electric field was 25.3 V/m and the magnetic flux density was $42.6{\mu}T$. The average electric field was 18.56 V/m and the magnetic flux density was $29.32{\mu}T$ in the power cable tunnel. As a result of comparison with the electric equipment technical standard, the electric field in the power cable tunnel was 0.5% of the electric equipment standard and 35.2% of the magnetic flux density. It's similar value that electric field is about robotic vacuum(15.53 V/m), and magnetic flux density is similar value about capsule- type coffee machine ($23.07{\mu}T$). The number of cable lines and the size of the electromagnetic waves were not proportional to each other through comparison of cable lines in the power cable tunnel. It was confirmed that 154 kV, rather than 22.9 kV, could have a greater influence on occupational.

A novel preparation of polyaniline in presence electric and magnetic fields

  • Hosseini, Seyed Hossein;Gohari, S. Jamal
    • Advances in materials Research
    • /
    • 제2권4호
    • /
    • pp.209-219
    • /
    • 2013
  • We have described primary studies on conductivity and molecular weight of polyaniline separately in the electric and magnetic fields when it is used in a field effect experimental configuration. We report further studies on doped in-situ deposited polyaniline. First we have chemically synthesized polyaniline by ammonium peroxodisulfate in acidic aques and organic solutions at different times. Then we measured mass and conductivity and obtained the best time of polymerizations. In continue, we repeated these reactions separately under different electric and magnetic fields in constant time and measured mass and conductivity. The polyaniline is characterized by gel permeation chromatography (GPC), UV-Visible spectroscopy and electrical conductivity. High molecular weight polyanilines are synthesized under electric field, $M_w$ = 520000-680000 g/mol, with $M_w/M_n$ = 2-2.5. The UV-Visible spectra of polyanilines oxidized by ammonium peroxodisulfate and protonated with dodecylbenzenesulfonic acid (PANi-DBSA), in N-methylpyrolidone (NMP), show a smeared polaron peak shifted into the visible. Electrical conductivity of polyanilines has been studied by four-probe method. The conductivity of the films of emeraldine protonated by DBSA cast from NMP are higher than 500 and 25 S/cm under 10 KV/m of potential) electric field and 0.1 T magnetic field, respectively. It shows an enhanced resistance to ageing too. By the next steps, we carried chemical polymerization at the best electric and magnetic fields at different times. Finally, resulted in finding the best time and amount of the fields. The longer polymerization time and the higher magnetic field can lead to degradation of polyaniline films and decrease conductivity and molecular mass.

The effect of field-line twist on the dynamic and electric current structures of emerging magnetic field on the Sun

  • An, Jun-Mo;Lee, Hwan-Hee;Kang, Ji-Hye;Magara, Tetsuya
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.102.1-102.1
    • /
    • 2011
  • In this study we use three-dimensional magnetohydrodynamic simulations to investigate how the dynamic state of emerging magnetic field is related to the twist of field lines. Emerging magnetic field forms a magnetic structure on the Sun where various kinds of activity such as solar flares, jets, and coronal mass ejections are observed. To understand the physical mechanism for producing such activity, we have to know the dynamic nature of this structure. Since flares are the manifestation of rapidly dissipating electric current in the corona, we also investigate the distribution of current density inside the structure and examine how it depends on the field-line twist. To demonstrate the dynamic structure of emerging magnetic field, we focus on the factors characterizing the geometric property and stratification of emerging magnetic field, such as the curvature of field line and the scale height of field strength. These two factors show that emerging field forms a two-part structure in which the central part is close to a force-free state while the outer marginal part is in a fairly dynamic state where magnetic pressure force is dominant. We discuss how the field-line twist affects the two-part structure and also explain a possible relation between electric current structure and sigmoid observed in a preflare phase.

  • PDF

Magnetic Field Analysis of Wireless Power Transfer via Magnetic Resonant Coupling or Electric Vehicle

  • Kesamaru, Katsumi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.83-87
    • /
    • 2014
  • This paper describes the magnetic field analysis of wireless power transfer via magnetic resonant coupling. The wireless power transfer system for supplying power to electric vehicle is developed. The parameters of coil transfer system are simulated by the finite element method (FEM). Therefore the coil structure of power transfer system can be accurately analyzed. This paper deals with 3kW wireless transfer system.

자계가 인가된 원통형 플라즈마 반응기에서 질소산화물(NOx)의 제거특성 (A removal characteristics of NOx at the cylinderical plasma reactor with magnetic field)

  • 이동훈;이태관;오정민;이두희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.104-108
    • /
    • 2004
  • The effect of magnetic field was measured on NOx removal for cylinder-wire plasma reactor with magnetic field applied to electric field vertically. Power was supplied to plasma reactor using rotating spark gap switch. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power was less than that without magnetic field because of lorenz's force. NOx removal rate of plasma reactor with magnetic field were higher, 10-15%, than that of plsama reactor without magnetic field. And NOx removal rate decreased with increasing gas flow rate.

  • PDF

Electric current control of creation and annihilation of sub-100 nm magnetic bubbles examined by full-field transmission soft X-ray microscopy

  • Je, Soong-Geun;Jung, Min-Seung;Im, Mi-Young;Hong, Jung-Il
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1201-1204
    • /
    • 2018
  • The effect of electric current pulses on a sub-100 nm magnetic bubble state in a symmetric Pt/Co multilayer was directly observed using a full-field transmission soft X-ray microscope (MTXM). Field-induced evolution of the magnetic stripe domains into isolated bubbles with their sizes down to 100 nm was imaged under varying external magnetic fields. Electric current pulses were then applied to the created magnetic bubbles, and it was observed that the bubbles could be either created or annihilated by the current pulse depending on the strength of applied magnetic field. The results suggest that the Joule heating plays a critical role in the formation and/or elimination of the bubbles and skyrmions. Finally, the schematic phase diagram for the creation and annihilation of bubbles is presented, suggesting an optimized scheme with the combination of magnetic field and electric current necessary to utilize skyrmions in the practical devices.

22.9[kV] 배전선로 주변의 전장과 자장의 분포 (Profiles of Electric and Magnetic Fields around 22.9[kV] Distribution Lines)

  • 이복희;;박종순;길형준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.178-178
    • /
    • 1999
  • In recent years, the electromagnetic environments are varied with the increase of power consumption and the spread of household electric appliances. Most of the interests to date have concentrated in the area of human health effects associated with exposure to power frequency electric and magnetic fields, and thus the precise measurement and analysis are required. In this paper, the measurements and analysis of the extremely low frequency(ELF) electric and magnetic fields produced by actual 22.9[kV] distribution lines were performed. The experiments have been carried out by lateral profile, and the theoretical analyses were made by use of FIELDS program for the sate of comparison with the experimental data. Electric and magnetic field intensity were strong under power distribution lines, and were inversely proportional to lateral distance. The profiles of electric and magnetic fields were M and ∩ shapes, respectively, and the measured data were good in agreement with the theoretical results. Both the electric and magnetic field intensity were increased with increasing the measurement height.

송전 선로 극저주파 자기장 저감지수(FRF) 특성 해석 (Analysis of ELF Magnetic Field Reduction Factor of Electric Power Transmission Line)

  • 명성호;조연규;이동일;임윤석
    • 한국전자파학회논문지
    • /
    • 제17권11호
    • /
    • pp.1132-1142
    • /
    • 2006
  • 본 연구는 송전 선로 여러 가지 유형의 극저주파 자기장 저감 적용 모델을 조사하고 그 효과를 분석하였다. 본 연구에서는 154 kV 수평 배열 송전 선로를 기본으로 하여 적용 가능한 다양한 자기장 저감 모델에 대하여 적용시 얻게 되는 자기장 저감지수(Field Reduction Factor)를 검토하였다. 그 결과 compact 모델 채용시에는 상간거리 compact화 비율과 자기장 저감지수가 거의 비례하였으며, diamond 모델 및 transposed 선로 배치의 경우는 50 %에 근접한 자기장 저감이 가능하였다. 배전 선로에 적용이 가능한 삼각형 배열은 33 % 정도, 2회선 split는 50 % 정도 저감 효과가 나타나는 것으로 분석되었으며 수평 multi split 모델의 경우는 80 %까지 자기장 저감을 얻을 수 있었다.

Electromagnetic Wave는 어떻게 발생하나\ulcorner (How Do Electromagnetic Waves Originate\ulcorner)

  • 김영상;고재중;강상욱;이영주;강유진;서일환
    • 한국결정학회지
    • /
    • 제14권1호
    • /
    • pp.25-31
    • /
    • 2003
  • 가속된 전자가 전자파의 원이다. 전자가 가속운동을 하면 그 전자에 의한 전장도 가속운동을 한다. 이 변하는 전장은 변하는 자장을 만들고 변하는 자장은 변하는 전장을 만드는 이 과정이 스스로 영구 반복된다. 이렇게 서로 연관되어 생성된 B와 E의 선들은 폐쇄된 loop들을 형성하면서 그 파원으로부터 속력 c로 멀어져 가는데 이 전장 및 자장을 전자파라 한다. 전자파의 모든 성질은 Maxwell의 식에서 수학적으로 추론된다.

X-ray scattering study on the electric field-induced interfacial magnetic anisotropy modulation at CoFeB / MgO interfaces

  • Song, Kyung Mee;Kim, Dong-Ok;Kim, Jae-Sung;Lee, Dong Ryeol;Choi, Jun Woo
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1212-1217
    • /
    • 2018
  • The electric field-induced modifications of magnetic anisotropy in CoFeB/MgO systems are studied using X-ray resonant magnetic scattering and magneto-optical Kerr effect. Voltage dependent changes of the magnetic anisotropy of -12.7 fJ/Vm and -8.32 fJ/Vm are observed for Ta/CoFeB/MgO and Hf/CoFeB/MgO systems, respectively. This implies that the interfacial perpendicular magnetic anisotropy is reduced (enhanced) when electron density is increased (decreased). X-ray resonant magnetic scattering measurements reveal that the small in-plane magnetic component of the remanent state of CoFeB/MgO systems with weak magnetic anisotropy changes depending on the applied voltage leading to modification of the magnetic anisotropy at the CoFeB/MgO interface.