실측데이터를 이용한 저에너지주택의 에너지성능평가 (Energy Performance Evaluation of Low Energy Houses using Metering Data)

  • 백남춘;김성범;오병칠;윤종호;신우철
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

초임계수 산화를 이용한 음이온교환수지 분해 (Supercritical Water Oxidation of Anionic Exchange Resin)

  • 한주희;한기도;도승회;김경숙;손순환
    • 대한환경공학회지
    • /
    • 제28권5호
    • /
    • pp.549-557
    • /
    • 2006
  • 화력발전소에서 발생하는 폐 음이온교환수지를 분해하기 위해 초임계수 산화 특성 연구를 진행하였다. 폐수지는 음이온교환수지와 양이온교환수지가 혼합된 상태로 배출되었으며, 혼합된 폐수지에서 고-액 유동층을 이용하여 음이온수지를 분리하였다. 분리된 음이온 수지는 원소분석과 열분석을 통해 양이온 수지가 혼합되지 않았음을 확인하였다. 음이온수지를 고압 펌프를 이용하여 초임계수 산화 반응 장치에 연속적으로 주입하기 위해 습식 ball mill을 이용하여 분쇄, 슬러리로 제조하였다. 압력 25.0 MP콘 체류시간 2분, 반응 온도 $500^{\circ}C$에서 처리수의 COD는 99.9%이상 분해됨을 확인하였지만, 총 질소 분해율은 41% 정도로 나타났으며, 슬러리에 질산을 혼합하면 처리수의 총 질소가 감소하였다. 처리수의 COD와 총 질소(T-N) 함량을 목적변수로 설정하여 음이온 수지 슬러리를 분해하는 최적 조건을 도출하기 위해 통계적 실험계획법인 중심합성계획법을 적용하였다. 처리수의 COD는 반응 온도 $500{\sim}540^{\circ}C$, 압력 25.0 MPa, 반응기 체류시간 2분 조건에서 $99.9{\sim}100%$까지 충분히 분해되었으며, 온도 변화와 질산 주입량 변화에 영향을 받지 않았다. 그러나 처리수의 총 질소는 질산 주입량의 변화에 대한 영향이 큰 것으로 확인되었다. 처리수의 총 질소는 회귀분석을 통해 질산 주입량의 함수로 나타낼 수 있었으며, 결정계수($r^2$)는 95.8%로 계산되었다.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발 (Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • 제22권4호
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

지열 난방시스템을 이용한 분만돈사의 난방효과 분석 (Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House)

  • 최희철;박재홍;송준익;나재천;김민지;방한태;강환구;박성복;채현석;서옥석;유영선;김태원
    • 한국축산시설환경학회지
    • /
    • 제16권3호
    • /
    • pp.205-215
    • /
    • 2010
  • 지열히트펌프를 이용한 축사용 냉난방시스템을 개발하고 농장 적용성을 검토하기 위하여 330 $m^2$ 규모의 농장에 개발 시스템을 설치하여 돈사에서의 난방 이용효과를 분석하였으며, 그 결과는 다음과 같다. 1. 지열 난방시 부하량은 24,104 kcal이었으며 농장시험 지열이용 냉난방시스템의 제원은 히트펌프 용량은 10 USRT 였으며, 상부 덕트형 30,000 kcal 홴코일유니트를 사용하였으며 FCU의 풍량은 90 $m^3$/분 이었다. 2. 지열 난방 1주령시 외부 최고기온 $14.2^{\circ}C$, 최저 영하 $9.3^{\circ}C$일때 시험구는 평균 $21.5^{\circ}C$로서 대조구 $19.8^{\circ}C$에 비하여 높았다. 3. 지열 난방 시험돈사의 먼지 농도는 PM10 185.3, PM2.5 40, PM1.0 $23.4{\mu}g/m^3$으로 대조구 PM10 481.4, PM2.5 47, PM1.0 $28.2{\mu}g/m^3$에 비하여 낮았다.4. 지열 난방 시험돈사의 유해가스농도는 $CO_2$ 1,470, $NH_3$ 10.6, $H_2S$ 0.05 ppm으로서 대조구 $CO_2$ 2,025, $NH_3$ 23.3, $H_2S$ 0.69 ppm에 비하여 유의적으로 (p<0.05) 낮았다. 5. 지열난방시 복당 이유두수는 10.5두로 대조구 10.4두에 비하여 높았으며 이유시체 중도 6.93 kg으로 대조구 6.86 kg에 비하여 컸으며 특히 온도가 낮은 대조구에서 모돈사료 섭취량이 99.6 kg으로 시험구 88.2 kg 보다 유의적으로 (p<0.05) 많았다. 6. 지열 난방시 외부기온과 지하수 순환량에 있어서 외부기온이 낮을 경우 1일간 8.4-12.9톤으로 지하수 순환량이 많았다.