• 제목/요약/키워드: Electric Room

Search Result 469, Processing Time 0.025 seconds

Studies on the Energy Expenditure of the Use of the Electric Vacuum Cleaners (전기청소기 사용시의 에너지 소비량의 측정)

  • 신경주
    • Journal of the Korean Home Economics Association
    • /
    • v.20 no.4
    • /
    • pp.113-124
    • /
    • 1982
  • We have investited on the efficiency of the electric vacuum cleaners for household use. On this experiment, we have used the Expired Gas Analyer IHO6(SAN-EI, K.K) to get energy expenditure of house cleaning. The testing items are, (1) The difference of energy expenditure of cleaning for the each types of the test floors: Which are P-tile, Tatami, and 4 kinds of carpets. (2) The energy expenditure of cleaning for the room with a given quantity of furnitures: The volumes of furnitures are 0, 3, 10, 20% of the room with 2 kinds of chair. The results of the experiments are as follows. 1. The energy expenditure of cleaning for the types of test floors: Setting the energy expenditure on the basis of P-tile, Tatami needs 20~24% energy expenditure than P-tile, and carpet needs 60~64% energy expenditure than P-tile. 2. Cleaning time: The more the room has many furnitures, the more it takes longer. The types of vacuum cleaners, the Shoulder-type cleaner needs 1.19 times of the Upright-type, and the Cylender-type needs 1.08 times of the Upright-type. 3. The energy expenditure of cleaning for a given quantity of furnitures: The more the rooms has many furnitures, the more the energy expenditure increase. A 10% (20%) increases in the volume of the furniture causes a 100% (200%) increases in the energy expenditure of vacuum cleaners.

  • PDF

Construction and Application of Experimental Formula for Nonlinear Behavior of Ferroelectric Ceramics Switched by Electric Field at Room Temperature during Temperature Rise

  • Ji, Dae Won;Kim, Sang-Joo
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.1
    • /
    • pp.67-73
    • /
    • 2018
  • A poled lead zirconate titanate (PZT) cube specimen that is switched by an electric field at room temperature is subject to temperature increase. Changes in polarization and thermal expansion coefficients are measured during temperature rise. The measured data are analyzed to obtain changes in pyroelectric coefficient and strain during temperature change. Empirical formulae are developed using linear or quadratic curve fitting to the data. The nonlinear behavior of the materials during temperature increase is predicted using the developed formulae. It is shown that the calculation results can be compared successfully with the measured values, which proves the accuracy and reliability of the developed formulae for the nonlinear behavior of the materials during temperature changes.

Evaluation of color reproduction characteristics of CRT display system (CRT 디스플레이 시스템의 색재현성 평가)

  • 김홍석;박승옥;백정기
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.259-264
    • /
    • 1999
  • The relationship is derived for color CRT display system between the spectral radian existence emitted and digital inputs. The amount of spectral radiant existence depends on the characteristics of the video board, electric circuits, and CRT as well as digital inputs. Especially, the function of this relationship changes as the amplifier gain and offset voltage of electric circuits. In this study, we set the test display system on the optimum state which satisfies gun independence characteristics by using the contrast and the brightness controls of display. Temporal stability, special uniformity, and color distinction of CRT display system are evaluated at the optimum state. Also contrasts in dark room and illuminated room are compared.

  • PDF

Analysis of Electromagnetic Shielding Performance for a BiMODAL Tram using an Electromagnetic Concentration Index (전자파의 집중도를 이용한 바이모달 트램의 전자파 차폐 성능 분석)

  • Choi, Nak-Sun;Jeung, Gi-Woo;Kim, Nam-Kyung;Song, Myung-Kon;Lee, Kang-Won;Mok, Jai-Kyun;Kim, Dong-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1378-1384
    • /
    • 2011
  • In this paper, the electromagnetic shielding performance of a BiMODAL Tram is investigated by means of an electromagnetic analysis tool, called HFSS. For the purposed of doing this, first, three-dimensional finite element modeling for the tram including electronic devices and engine room is carried out. Then, for quantitatively assessing the electromagnetic shielding performance of the tram's body, concentration indexes for electric field magnitude and time-average stored electric energy are introduced. From numerical results, it is inferred that the tram's body can protect the electronic devices and engine room against external electromagnetic waves from 30 MHz to 100 MHz.

Experimental Study on Living Room Lighting Environment for Residential Activities

  • Kim, Hyun-Ji;Woo, Seong-Jun;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.10-16
    • /
    • 2013
  • This study performed a subjective evaluation of the Semantic Differential (SD) method for living room activities to evaluate the living room lighting environment and investigated the relationship between these through luminance distribution in the space. As a result, three factors-"lightness", "emotion" and "calmness"-have been grouped together. According to the analysis of experimental variables, difference has been observed depending on color temperature, the dimming of the ceiling & cove lights and the use of down lights and a bracket. 'Conversation with Family', 'Having Fun with Family', 'Entertaining Guests' and 'Reading a Book or Newspaper' requires "lightness". In terms of "emotion"-centered activities, 'Watching TV' is the highest, but all three factors are related. In terms of "calmness"-centered activities, 'Relaxing' is the highest.

A Study on the Hand Drum Form Predict in the Wire Electric Discharge (와이어방전가공시 북량현상 예측에 관한 연구)

  • 김선진;성백섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.70-78
    • /
    • 2003
  • The purpose of this study was to present the method to choose the optimization machining condition for the wire electric discharge machine. This was completed by examining the ever-changing quality of the material and by improving the function of the wire electric discharge machine. Precision metal mold products and the unmanned wire electric discharge machining system were used and then applied in industrial fields. This experiment uses the wire electric discharge machine with brass wire electrode of 0.25mm. In this experiment, we changed no-node voltage to 7 and 9, pulse-on-time to 6$mutextrm{s}$, 8$mutextrm{s}$ and 10$mutextrm{s}$, pulse-off-time to 8$mutextrm{s}$, 10$mutextrm{s}$ and 13$mutextrm{s}$, and experimented on wire tension at room temperature by 1000gf, 1200gf, and 1400gf, respectively.

Reduction of Insulation thickness for EHV XLPE power cable (초고압 XLPE 전력케이블 절연두께 저감화)

  • Lee, Ki-Soo;Choi, Woong;Choi, Young-Hun;Choi, Bong-Nam;Kim, Do-Young;Yun, Duck-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2271-2273
    • /
    • 1999
  • The manufacturing technology of XLPE power cable ( e.g. gas curing, triple common extrusion, clean room, super-clean compound, etc.) had been developed in 1960's and the design parameter of insulation thickness for EHV XLPE power cable at present was determined in 1960's. But, the quality of XLPE power cable has been improved up to now. The re-evaluation of design parameter for insulation thickness reductions is required and so we performed weibull plotting test using model cable. This paper describes the evaluation details of the insulation characteristics according to weibull plotting test.

  • PDF

A comparison of resident's behavior of operating air conditioner according to the charge for electric (사용자의 전기요금 부담 여부에 따른 여름철 냉방기 사용 특성의 비교)

  • Kwon, Suh-Hyun;Choi, Yoo-Rim;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.301-305
    • /
    • 2006
  • An electrical bill is one of the various factors that influence on energy use of residents. This study focused on electrical bills and searched that whether electrical bills affect resident behavior of operating air conditioner and their controlled indoor climate. We surveyed two groups for field study ; the one is residents who live in a studio apartment in Seoul and they are charged for electric as energy consumption they used, and the other is residents who live in a university dormitory and they are not charged for their energy consumption. We measured how long they used the air conditioner for cooling, on/off temperature of air conditioner and room temperature for these two groups. Residents were interviewed about their cooling needs, decisions about when to turn on their air conditioner and so on. We found that dormitory group has much amount of time used the air conditioner than studio apartment group and there are differences of room temperature between two groups when they turn on or off air conditioner. The result shows that perception of money affects resident behavior of operating air conditioner and their acceptable thermal range.

  • PDF

Fatigue Crack Growth Characteristics of the Pressure Vessel Steel SA 508 Cl. 3 in Various Environments

  • Lee, S. G.;Kim, I. S.;Park, Y. S.;Kim, J. W.;Park, C. Y.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.526-538
    • /
    • 2001
  • Fatigue tests in air and in room temperature water were performed to obtain comparable data and stable crack measuring conditions. In air environment, fatigue crack growth rate was increased with increasing temperature due to an increase in crack tip oxidation rate. In room temperature water, the fatigue crack growth rate was faster than in air and crack path varied on loading conditions. In simulated light water reactor (LWR) conditions, there was little environmental effect on the fatigue crack growth rate (FCGR) at low dissolved oxygen or at high loading frequency conditions. While the FCGR was enhanced at high oxygen condition, and the enhancement of crack growth rate increased as loading frequency decreased to a critical value. In fractography, environmentally assisted cracks, such as semi-cleavage and secondary intergranular crack, were found near sulfide inclusions only at high dissolved oxygen and low loading frequency condition. The high crack growth rate was related to environmentally assisted crack. These results indicated that environmentally assisted crack could be formed by the Electrochemical effect in specific loading condition.

  • PDF