• Title/Summary/Keyword: Electric Residence

Search Result 37, Processing Time 0.028 seconds

Mixed Flow and Oxygen Transfer Characteristics of Vertical Orifice Ejector (수직 오리피스 이젝터의 혼합유동 및 산소전달 특성)

  • Kim, Dong Jun;Park, Sang Kyoo;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.61-69
    • /
    • 2015
  • The objective of this study is to experimentally investigate the mixed flow behaviors and oxygen transfer characteristics of a vertical orifice ejector. The experimental apparatus consisted of an electric motor-pump, an orifice ejector, a circulation water tank, an air compressor, a high speed camera unit and control or measurement accessories. The mass ratio was calculated using the measured primary flow rate and suction air flow rate with experimental parameters. The visualization images of vertically injected mixed jet issuing from the orifice ejector were qualitatively analyzed. The volumetric oxygen transfer coefficient was calculated using the measured dissolved oxygen concentration. At a constant primary flow rate, the mass ratio and oxygen transfer coefficient increase with the air pressure of compressor. At a constant air pressure of the compressor, the mass ratio decreases and the oxygen transfer coefficient increases as the primary flow rate increases. The residence time and dispersion of fine air bubbles and the penetration of mixed flow were found to be important parameters for the oxygen transfer rate owing to the contact area and time of two phases.

Estimation of Mean Air Exchange Rate and Generation Rate of Nitrogen Dioxide Using Box Model in Residence (주택에서 Box Model을 이용한 평균 환기율 및 이산화질소 발생량 추정)

  • Bae, Hyeon Ju;Yang, Won Ho;Son, Bu Sun;Kim, Dae Won
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.645-653
    • /
    • 2004
  • Indoor air quality is affected by source strength of pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate these factors by application of multiple measurements. For the total duration of 30 days, daily indoor and outdoor $NO_2$ concentrations were measured in 30 houses in Brisbane, Australia, and for 21 days in 40 houses in Seoul, Korea, respectively. Using a box model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated, Sub-sequently, the ventilation and source strength were estimated. In Brisbane, the penetration factors were $0.59\pm0.14$ and they were unaffected by the presence of a gas range. During sampling period, geometric mean of natural ventilation was estimated to be $l.l0\pm1.5l$ ACH, assuming a residential $NO_2$ decay rate of 0.8 hr^{-1}$ in Brisbane. In Seoul, natural ventilation was $1.15\pm1.73$ ACH with residential $NO_2$ decay rate of 0.94 hr^{-1}$ Source strength of $NO_2$ in the houses with gas range $(12.7\pm9.8$ ppb/hr) were significantly higher than those in houses with an electric range $(2.8\pm2,6$ ppb/hr) in Brisbane. In Seoul, source strength in the houses with gas range were $l6.8\pm8.2$ ppb/hr. Conclusively, indoor air quality using box model by mass balance was effectively characterized.

Decomposition of CFC-12($CCl_2F_2$) by Discharge Plasma (방전 플라스마에 의한 CFC-12($CCl_2F_2$)의 분해)

  • 강현춘;우인성;황명환;안형환;이한섭;조정국;강안수
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.93-100
    • /
    • 1999
  • Decomposition efficiency, power consumption, and applied voltage of CFC(Chlorofluorocatbon) were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of CFC-12 with various electric frequencies(5~50kHz). flow rates (100~1,000mL/min), initial concentrations(100~1,000ppm), electrode materials(W, Cu, Al). electrode thickness(1, 2, 3mm) and reference gases($N_2$, $O_2$, air) were measured and the products were analyzed with FT-IR. Experimental results showed that at the frequency of 10kHz, the highest decomposition efficiency of 92.7% for CFC-12 were observed at the power consumptions of 29.6W. respectively, and that decomposition efficiency decreased with increasing frequency above 20kHz and decomposition efficiency per unit power were 3.13%/W for CFC-12. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3m. As the electrode material, decomposition efficiency was in order that tungsten(W), copper(Cu), aluminum (Al). Decomposition of CFC-12 in the reference gas of $N_2$ showed the highest efficiency among three reference gases, and then the effect of reference gas on the decomposition efficiency decreased in order of air and $O_2$. The optimum power for the maximum decomposition efficiency was 25.3W for CFC.

  • PDF

Comparative Study on the Runoff Process of Granite Drainage Basins in Korea and Mongolia

  • Tanaka, Yukiya;Matsukura, Yukinori
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.79-84
    • /
    • 2003
  • This study revealed the differences in runoff processes of granite drainage basins in Korea and Mongolia by hydrological measurements in the field. The experimental drainage basins are chosen in Korea (K-basin) and Mongolia (M-basin). Occurrence of intermittent flow in K-basin possibly implies that very quick discharge dominates. The very high runoff coefficient implies that most of effective rainfall quickly discharge by throughflow or pipeflow. The Hortonian overlandflow is thought to almost not occur because of high infiltration capacity originated by coarse grain sized soils of K- basin. Very little baseflow and high runoff coefficient also suggest that rainfall almost does not infiltrate into bedrocks in K-basin. Flood runoff coefficient in M-basin shows less than 1 %. This means that most of rainfall infiltrates or evaporates in M-basin. Runoff characteristics of constant and gradually increasing discharge imply that most of rainfall infiltrates into joint planes of bedrock and flow out from spring very slowly. The hydrograph peaks are sharp and their recession limbs steep. Very short time flood with less than 1-hour lag time in M-basin means that overland flow occurs only associating with rainfall intensity of more than 10 mm/hr. When peak lag time shows less than 1 hour for the size of drainage area of 1 to 10 km2, Hortonian overland flow causes peak discharge (Jones, 1997). The results of electric conductivity suggest that residence time in soils or weathered mantles of M-basin is longer than that of K-basin. Qucik discharge caused by throughflow and pipeflow occurs dominantly in K-basin, whereas baseflow more dominantly occur than quick discharge in M-basin. Quick discharge caused by Hortonian overlandflow only associating with rainfall intensity of more than 10 mm/hr in M-basin.

  • PDF

Domestic Computer Market and Future Direction of Barebone PC - Focusing on Home Ubiquitous Environment - (국내 컴퓨터시장의 현황과 베어본(barebone)PC의 발전방향 - 가정 유비쿼터스 환경을 중심으로 -)

  • Kim, Joung-Soo;Moon, Charn
    • Archives of design research
    • /
    • v.19 no.2 s.64
    • /
    • pp.333-342
    • /
    • 2006
  • Consumers have paid attention to various functions of PC's nowadays from its efficiency in the past. This study set limits to adapted computers by consumer needs for their residence facilities and ubiquitous environment in our society. The purpose of this study is to suggest high potentialities of adapted computers and it's design for materializing house ubiquitous system. It has come out from analyzing PC market. The result is that Barebone PC, a kind of set PC, could be one of the most actual way for materializing house ubiquitous system. This study suggests many potentialities of Barebone PC which invites modular system. The existing Barebone PC is a kind of semimanufactures, however the new Barebone PC in this study is a expanded concept of modular system that connected to the area of the electric home appliances. This is inspected by analyzing the relation among potentialities and impotance of set PC design and module.

  • PDF

Analysis of the Characteristics of the Change in the Moisture Rate of Landfill with Recirculation Water Injection (재순환수 주입에 따른 매립장 함수율 변화특성 분석)

  • Kim, Young-Kyu;Choi, Won-Young;Chun, Seung-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.5
    • /
    • pp.39-48
    • /
    • 2021
  • Analysis of the change in water content and distribution was conducted according to the supply of recirculation water to a landfill. An excavation sample analysis showed that the recirculation water injection zone had water content 8.8% point higher than that of the non-injection zone, after 8 months of operation. And due to the influence of recirculation water supply by vertical wells in injection zones, the water content increases along with depth more clearly than non-injection zone. According to an electrical specific-resistivity survey after 13 months of operation, the water content got higher towards the bottom of the landfill. The water transmission coefficient is 8.72×10-4 cm/sec for injection zones and 3.36×10-5 cm/sec for the intermediate cover layer; analysis shows that the intermediate cover layer may affect the penetration velocity of water supplied by the horizontal injection tube. For the scientific design and operation of re-injection facilities, it was deemed necessary to follow-up research on the residence time and behavior of re-injection water considering the ratio of recirculation water supply in horizontal and vertical tubes, and pitcher coefficient of intermediate and waste layers.

Characteristics of Packed-bed Plasma Reactor with Dielectric Barrier Discharge for Treating (에틸렌 처리를 위한 충진층 유전체배리어방전 플라즈마 반응기의 특성)

  • Sudhakaran, M.S.P.;Jo, Jin Oh;Trinh, Quang Hung;Mok, Young Sun
    • Applied Chemistry for Engineering
    • /
    • v.26 no.4
    • /
    • pp.495-504
    • /
    • 2015
  • This work investigated the characteristics of a packed-bed plasma reactor system and the performances of the plasma reactors connected in series or in parallel for the decomposition of ethylene. Before the discharge ignition, the effective capacitance of the ${\gamma}$-alumina packed-bed plasma reactor was larger than that of the reactor without any packing, but after the ignition the effective capacitance was similar to each other, regardless of the packing. The energy of electrons created by plasma depends mainly on the electric field intensity, and was not significantly affected by the gas composition in the range of 0~20% (v/v) oxygen (nitrogen : 80~100% (v/v)). Among the various reactive species generated by plasma, ground-state atomic oxygen and ozone are understood to be primarily involved in oxidation reactions, and as the electric field intensity increases, the amount of ground-state atomic oxygen relatively decreases while that of nitrogen atom increases. Even though there are many parameters affecting the performance of the plasma reactor such as a voltage, discharge power, gas flow rate and residence time, all parameters can be integrated into a single parameter, namely, specific input energy (SIE). It was experimentally confirmed that the performances of the plasma reactors connected in series or in parallel could be treated as a function of SIE alone, which simplifies the scale-up design procedure. Besides, the ethylene decomposition results can be predicted by the calculation using the rate constant expressed as a function of SIE.

Effects of Steam and Temperature on CO2 Capture Using A Dry Regenerable Sorbent in a Bubbling Fluidized Bed (기포 유동층 반응기에서 건식 재생 흡수제를 이용한 이산화탄소 회수에 미치는 스팀 및 온도의 영향)

  • Seo, Yongwon;Moon, Young Sub;Jo, Sung-Ho;Ryu, Chong Kul;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.537-541
    • /
    • 2005
  • A bubbling fluidized bed reactor was used to study $CO_2$ capture from flue gas using a sodium-based dry regenerable sorbent, sorbA which was manufactured by Korea Electric Power Research Institute. A dry sorbent, sorbA, consists of $Na_2CO_3$ for absorption and supporters for mechanical strength. $CO_2$ capture was effective in the lower temperature range of $50-70^{\circ}C$, while regeneration occurred in the range of $120-300^{\circ}C$. To increase initial $CO_2$ removal, some amount of steam was absorbed in the sorbents before injecting simulated flue gas. It was possible to remove most $CO_2$ for 1-2 minutes at $50^{\circ}C$ and residence time of 2 seconds with steam pretreatment. Little or no reduction in initial reaction rate and capture capacity was observed in multicycle tests. The carbonated and regenerated sorbent samples were analyzed by NMR to confirm the extent of reaction. The results obtained in this study can be used as basic data for the scale-up design and operation of the $CO_2$ capture process with two fluidized bed reactors.

A Study on the Improvement Plans of Police Fire Investigation (경찰화재조사의 개선방안에 관한 연구)

  • SeoMoon, Su-Cheol
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.9 no.1
    • /
    • pp.103-121
    • /
    • 2006
  • We are living in more comfortable circumstances with the social developments and the improvement of the standard of living, but, on the other hand, we are exposed to an increase of the occurrences of tires on account of large-sized, higher stories, deeper underground building and the use of various energy resources. The materials of the floor in a residence modern society have been going through various alterations in accordance with the uses of a residence and are now used as final goods in interioring the bottom of apartments, houses and shops. There are so many kinds of materials you usually come in contact with, but in the first place, we need to make an experiment on the spread of the fire with the hypocaust used as the floors of apartments, etc. and the floor covers you usually can get easily. We, scientific investigators, can get in contact with the accidents caused by incendiarism or an accidental fire closely connected with petroleum stuffs on the floor materials that give rise to lots of problems. on this account, I'd like to propose that we conduct an experiment on fire shapes by each petroleum stuff and that discriminate an accidental tire from incendiarism. In an investigation, it seems that finding a live coal could be an essential part of clearing up the cause of a tire but it could not be the cause of a fire itself. And besides, all sorts of tire cases or fire accidents have some kind of legislation and standard to minimize and at an early stage cope with the damage by tires. That is to say, we are supposed to install each kind of electric apparatus, automatic alarm equipment, automatic fire extinguisher in order to protect ourselves from the danger of fires and check them at any time and also escape urgently in case of fire-outbreaking or build a tire-proof construction to prevent flames from proliferating to the neighboring areas. Namely, you should take several factors into consideration to investigate a cause of a case or an accident related to fire. That means it's not in reason for one investigator or one investigative team to make clear of the starting part and the cause of a tire. accordingly, in this thesis, explanations would be given set limits to the judgement and verification on the cause of a fire and the concrete tire-spreading part through investigation on the very spot that a fire broke out. The fire-discernment would also be focused on the early stage fire-spreading part fire-outbreaking resources, and I think the realities of police tire investigations and the problems are still a matter of debate. The cause of a fire must be examined into by logical judgement on the basis of abundant scientific knowledge and experience covering the whole of fire phenomena. The judgement of the cause should be made with fire-spreading situation at the spot as the central figure and in case of verifying, you are supposed to prove by the situational proof from the traces of the tire-spreading to the fire-outbreaking sources. The causal relation on a fire-outbreak should not be proved by arbitrary opinion far from concrete facts, and also there is much chance of making mistakes if you draw deduction from a coincidence. It is absolutely necessary you observe in an objective attitude and grasp the situation of a tire in the investigation of the cause. Having a look at the spot with a prejudice is not allowed. The source of tire-outbreak itself is likely to be considered as the cause of a tire and that makes us doubt about the results according to interests of the independent investigators. So to speak, they set about investigations, the police investigation in the hope of it not being incendiarism, the fire department in the hope of it not being problems in installments or equipments, insurance companies in the hope of it being any incendiarism, electric fields in the hope of it not being electric defects, the gas-related in the hope of it not being gas problems. You could not look forward to more fair investigation and break off their misgivings. It is because the firing source itself is known as the cause of a fire and civil or criminal responsibilities are respected to the firing source itself. On this occasion, investigating the cause of a fire should be conducted with research, investigation, emotion independent, and finally you should clear up the cause with the results put together.

  • PDF

A Study on the Optimal Process Parameters for Recycling of Electric Arc Furnace Dust (EAFD) by Rotary Kiln (Rotary Kiln에 의한 전기로 제강분진(EAFD)의 재활용을 위한 최적의 공정변수에 관한 연구)

  • Jae-hong Yoon;Chi-hyun Yoon;Myoung-won Lee
    • Resources Recycling
    • /
    • v.33 no.4
    • /
    • pp.47-61
    • /
    • 2024
  • As a recycling technology for recovering zinc contained in large amounts in electric arc furnace dust (EAFD), the most commercialized technology in the world is the Wealz Kiln Process. The Wealz Kiln Process is a process in which components such as Zn and Pb in EAFD are reduced/volatile (endothermic reaction) in high-temperature Kiln and then re-oxidized (exothermic reaction) in the gas phase and recovered in the form of Crude zinc oxide (60wt%Zn) in the Bag Filter installed at the rear end of Kiln. In this study, an experimental Wealz kiln was produced to investigate the optimal process variable value for practical application to the recycling process of large-scale kiln on a commercial scale. Additionally, Pellets containing EAFD, reducing agents, and limestone were continuously loaded into Kiln, and the amount of input, heating temperature, and residence time were examined to obtain the optimal crude zinc oxide recovery rate. In addition, the optimal manufacturing conditions of Pellets (drum tilt angle, moisture addition, mixing time, etc.) were also investigated. In addition, referring to the SiO2-CaO-FeO ternary system diagram, the formation behavior of a low melting point compound, a reaction product inside Kiln according to the change in the basicity of Pellet, and the reactivity (adhesion) with the castable constructed on the inner wall of Kiln were investigated. In addition, in order to quantitatively investigate the possibility of using anthracite as a substitute for Coke, a reducing agent, changes in the temperature distribution inside Kiln, where oxidation/reduction reactions occur due to an increase in the amount of anthracite, the quality of Crude zinc oxide, and the behavior of tar in anthracite were also investigated.