• Title/Summary/Keyword: Electric Rates

Search Result 444, Processing Time 0.03 seconds

Effect of Electrode Process Variables in case of Decomposition of $NO_x$ by SPCP (연면방전에 의한 질소산화물의 분해시 전극 공정변수에 대한 영향)

  • 안형환;강현춘
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.543-563
    • /
    • 1999
  • For hazardous air pollutants(HAP) such as NO and $NO_2$ decomposition efficiency, power consumption, and applied voltage were investigated by SPCP(surface induced discharge plasma chemical processing) reactor to obtain optimum process variables and maximum decomposition efficiencies. Decomposition efficiency of HAP with various electric frequencies(5~50 kHz), flow rates(100~1,000 mL/min) initial concentrations(100~1,000 ppm), electrode materials(W, Cu, Al), electrode thickness(1, 2, 3 mm) and number of electrode windings(7, 9, 11) were measured. Experimental results showed that for the frequency of 10 kHz, the highest decomposition efficiency of 94.3% for NO and 84.7% for $NO_2$ were observed at the poser consumptions of 19.8 and 29W respectively and that decomposition efficiency decreased with increasing frequency above 20 kHz. Decomposition efficiency was increased with increasing residence times and with decreasing initial concentration of pollutants. Decomposition efficiency was increased with increasing thickness of discharge electrode and the highest decomposition efficiency was obtained for the electrode diameter of 3mm in this experiment. As the electrode material, decomposition efficiency was in order : tungsten(W), copper(Cu), aluminum(Al).

  • PDF

Modeling of the Charge-discharge Behavior of a 12-V Automotive Lead-acid Battery (차량용 12-V 납축전지의 충·방전 모델링)

  • Kim, Ui Seong;Jeon, Sehoon;Jeon, Wonjin;Shin, Chee Burm;Chung, Seung Myun;Kim, Sung Tae
    • Korean Chemical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.242-248
    • /
    • 2007
  • For an optimal design of automotive electric system, it is important to have a reliable modeling tool to predict the charge-discharge behaviors of the automotive battery. In this work, a two-dimensional modeling was carried out to predict the charge-discharge behaviors of a 12-V automotive lead-acid battery. The model accounted for electrochemical kinetics and ionic mass transfer in a battery cell. In order to validate the modeling, modeling results were compared with the experimental data of the charge-discharge behaviors of a lead-acid battery. The discharge behaviors were measured with three different discharge rates of C/5, C/10, and C/20 at operating temperature of $25^{\circ}C$. The batteries were charged with constant current of 30A until the charging voltage reached to a predetermined value of 14.24 V and then the charging voltage was kept constant. The discharge and charge curves from the measurements and modeling were in good agreement. Based on the modeling, the distributions of the electrical potentials of the solid and solution phases, the porosity of the electrodes, and the current density within the electrodes as well as the acid concentration can be predicted as a function of charge and discharge time.

Studies on the Optical and the Electrical Characterization of Organic Electroluminescence Devices of Europium Complex Fabricated with PVD(Physical Vopor Deposition) Technique (진공 증착법에 의하여 제작한 Europium complex 유기 박막 전기발광소자의 광학적.전기적 특성에 관한 연구.)

  • Lee, Myeong-Ho;Lee, Han-Seong;Kim, Yeong-Gwan;Kim, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.285-295
    • /
    • 1999
  • Electroluminescent(EL) devices based on organic materials have been of great interest due to their possible applications for large-area flat-panel displays. They are attractive because of their capability of multi-color emission, and low operation voltage. An approach to realize such device characteristics is to use active layers of lanthanide complexes with their inherent extremely sharp emission bands in stead of commonly known organic dyes. In general, organic molecular compounds show emission due to their $\pi$-$\pi*$ transitions resulting in luminescence bandwidths of about 80 to 100nm. Spin statistic estimations lead to an internal quantum efficiency of dye-based EL devices limited to 25%. On the contrary, the fluorescence of lanthanide complexes is based on an intramolecular energy transfer from the triplet of the organic ligand to the 4f energy states of the ion. Therefore, theoretical internal quantum efficiency is principally not limited. In this study, Powders of TPD, $Eu(TTA)_3(phen) and AlQ_3$ in a boat were subsequently heated to their sublimation temperatures to obtain the growth rates of 0.2~0.3nm/s. Organic electrolumnescent devices(OELD) with a structure of $glass substrate/ITO/Eu(TTA)_3(phen)/AI, glass substrate/ITO/TPD/Eu(TTA)_3(phen)/AI and glass substrate/ITO/TPD/Eu(TTA)_3(phen)/AIQ_3AI$ structures were fabricated by vacuum evaporation method, where aromatic diamine(TPD) was used as a hole transporting material, $Eu(TTA)_3(phen)$ as an emitting material, and Tris(8-hydroxyquinoline)Aluminum$(AlQ_3)$ as an electron transporting layer. Electroluminescent(EL) and current density-voltage(J-V) characteristics of these OELDs with various thickness of $Eu(TTA)_3(phen)$ layer were investigated. The triple-layer structure devices show the red EL spectrum at the wavelength of 613nm, which is almost the same as the photoluminescent(PL) spectrum of $Eu(TTA)_3(phen)$.It was found from the J-V characteristics of these devices that the current density is not dependent on the applied field, but on the electric field.

  • PDF

Endoplasmic Reticulum (ER) Stress and Apoptosis in Parthenogenetic Porcine Embryos following Different Combination of Activation Methods

  • Park, Hye-Bin;Park, Yeo-Reum;Lee, Hwa-Yeon;Bae, Hyo-Kyung;Lee, Seunghyung;Park, Choon-Keun;Yang, Boo-Keun;Cheong, Hee-Tae
    • Journal of Embryo Transfer
    • /
    • v.32 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • This study was conducted to investigate the effect of activation method on the endoplasmic reticulum (ER) stress induction, apoptosis and in vitro development of porcine parthenogenetic embryos. Porcine in vitro matured oocytes were activated by four activation methods; 1) electric stimulus (ES) (E), 2) $ES+10{\mu}M$ Ca-ionophore (A23187) treatment (EC), 3) ES+2 mM 6-dimethylaminopurine (6-DMAP) treatment (ED), or 4) ES+A23187 and 6-DMAP treatments (ECD). Parthenogenetic embryos were sampled to analyze x-box binding protein 1 (Xbp1) mRNA, ER stress-associated genes and apoptosis genes at 3 h after ES and the 1-cell and blastocyst stages. In the EC group, the band intensity of spliced Xbp1 (Xbp1s) mRNA was higher than those of the other groups at the 3 h and 1-cell stage, and higher than that of the E group at the blastocyst stage. Four ER stress-associated genes were expressed at the highest level in the EC group and weakly expressed in the ED group at 3 h after activation. However, most of the genes were highly expressed at the 1-cell and blastocyst stages with some variation in the EC and ECD groups. Expression of Bcl-2-associated X protein (Bax) and caspase-3 mRNA was significantly higher in the EC group than in the other groups at all development stages. The developmental rates to the blastocyst stage were higher in the ED and ECD groups than in the E and EC groups. These results suggest that the intracellular ER stress of parthenogenetic porcine embryos is affected by the activation method and subsequently lead to the apoptosis of embryos.

Changes in Physicochemical Properties and Bioactivity of Pesticide Spray Solutions (농약살포액의 이화학적 특성과 생물활성 변화)

  • Jin, Yong-Duk;Lee, Sang-Bum;Lee, Sang-Guei;Oh, Byung-Youl
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.411-421
    • /
    • 2005
  • This study was carried out to establish rational methodologies for the use of pesticide formulations to be sprayed after water-dilution. Hardness and electric conductivity of six major river water and ground water sampled from 52 sites in major rice-growing areas across the country ranged from 5 to 324 ppm(av. 90 ppm) and from 0.038 to 1.078 dS/m(av. 0.265 dS/m), respectively, which are acceptable for diluent water of pesticides. The pH changes in pesticide spray solutions with time after preparation mainly depended on the pH of the water used for pesticide dilution. The surface tensions of pesticide spray solutions reduced slightly with time after preparation, irrespective of kinds of pesticide formulations. Suspensibility of WPs became worse with an increase in the hardness and salt concentrations of diluent water, even though the degree was negligible. Emulsion stability of ECs became worse with an increase in hardness and salt concentrations of diluent water. Degradation rates of the active ingredients of pesticide spray solutions 3 days after preparation were less than 5%, regardless of mixing or non-mixing of two or more pesticides. Consequently, the spray solutions of most pesticides were usable until two to three days after preparation unless physical properties deteriorated. The tank-mixing order of EC and WP formulations did not make any differences in all the physical properties of pesticide spray solutions. However, the proper order for the tank-mixing of compatible pesticides was WP, WG, SC, EC, and SL, because the order is easy to prepare the pesticide spray solutions. The efficacy of pesticide spray solutions on the respective target pathogens and insect pests of rice plants three days after preparation was recorded over 95% of that of 0 day, which was almost the same as that of the solutions applied punctually after preparation.

Changes in Chemical Components of Stagnant Water by Tillage Method and Amount of Nitrogen Application in Wet Seeded Rice after Barley Straw Mulching (논에 보리짚 시용시 경운방법 및 질소시비량에 따른 논물의 화학성분 변화)

  • Cheong, Jin-Il;Choi, Min-Gyu;Noh, Tae-Hwan;Lee, Jung-Ho;Kwon, Tae-Ohu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.4
    • /
    • pp.411-419
    • /
    • 1996
  • The experiment was aimed to determine a change of chemical component in irrigatted water based on different tillage methods and nitrogen rates under mulching of barley straw in direct seeded rice. There was no difference in water pH of no-tillaged plot but high in tillaged plot until 10 days after treatment. The electric conductivity(EC) of the water was higher in no-tillaged plot than in tillaged plot. However, the dissolved oxygen content was vice versa. The content of NH$_4$-N was high in higher application rate of N fertilizer without the tillage. Mean while, NO$_3$-N content was highly affected by no-till aged plot particularly in between application time and fertilizer rate but not in tillaged plot. There was higher in P043- content with the no-tillaged plot compared to the tillaged plot. It was big difference with higher application rate of the fertilizer. Soil cations were high in much application of fertilizer without the tillage.

  • PDF

A Study on the Prior Leaching and Recovery of Lithium from the Spent LiFePO4 Cathode Powder Using Strong Organic Acid (강유기산을 이용한 폐LiFePO4 양극분말로부터 리튬의 선침출에 대한 연구)

  • Dae-Weon Kim;Soo-Hyun Ban;Hee-Seon Kim;Jun-Mo Ahn
    • Clean Technology
    • /
    • v.30 no.2
    • /
    • pp.105-112
    • /
    • 2024
  • Globally, the demand for electric vehicles has surged due to greenhouse gas regulations related to climate change, leading to an increase in the production of used batteries as a consequence of the battery life issue. This study aims to selectively leach and recover valuable metal lithium from the cathode material of spent LFP (LiFePO4) batteries among lithium-ion batteries. Generally, the use of inorganic acids results in the emission of toxic gases or the generation of large quantities of wastewater, causing environmental issues. To address this, research is being conducted to leach lithium using organic acids and other leaching agents. In this study, selective leaching was performed using the organic acid methane sulfonic acid (MSA, CH3SO3H). Experiments were conducted to determine the optimal conditions for selectively leaching lithium by varying the MSA concentration, pulp density, and hydrogen peroxide dosage. The results of this study showed that lithium was leached at approximately 100%, while iron and phosphorus components were leached at about 1%, verifying the leaching efficiency and the leaching rates of the main components under different variables.

Effect of Electric Purse Conditions on the Fusion and Development Embryos Produced by Ear Cell Nuclear Transfer in Brindle Coated Hanwoo (Korean Cattle) (칡소의 귀세포를 이용한 핵이식에서 전기융합조건이 융합 및 배발달에 미치는 영향)

  • 최은주;이호준;민관식;김창근;정영채;윤종택
    • Korean Journal of Animal Reproduction
    • /
    • v.27 no.1
    • /
    • pp.87-93
    • /
    • 2003
  • This study was conducted to investigate the effects of embryo development by fusion condition on the nuclear transfer with brindle coated cow's ear cells. Ear cells were transferred into an enucleated oocyte and fused with cytoplasm in the fusion condition with 1.9kv/cm, 2.0kv/cm, 2.1kv/cm each 10 and 20ug duration Nuclear transfer embryo were activeted with a combination of 5ug/ml and 1.9mM 6-DMAP (4min, 4h). Fusion rate was 51∼68% range among fusion condition (1.9, 2.0, 2.1kv/cm; 10, 20us). But, cytoplasm lysis rate was increased by higher electric condition (0∼51.8% range). Each parameter's cleavage and blastocyst formation rate were 1.9kv/cm for 10us (75.8 and 19.5%), 20us (69.8 and 48.6%), 2.0kv/cm for 10us (76.9 and 20.0%), 20 us (68.5 and 40.9%), 2.1kv/cm for 10us (70.5 and 44.2%), 20 us (68.5 and 27.0%). We compared the effectiveness of cloning for between brindle coated cow's ear cells and Hanwoo fetal fibroblast cells. There was no significant differences in the fusion rate and developmental rate to the blastocyst stage. After transfer of blastocysts derived from nuclear transfer embryos, pregnancy rates of the Hanwoo fetal fibroblast cells and brindle coated cow's ear cells were checked pregnant on day 60 as assessed by ultrasonography, 40% (2/5) and 15.8% (3/19), respectively. This studies conclude that brindle coated cow's ear cells have the developmental potentiality to term by nuclear transfer. These results demonstrate that the increased the field strength was to be profitable for development of blastocyst or reduce of cytoplasm's damage than increasing the pulse duration.

A Study on Improvement Methods of Cost Estimation in Order for the Proper Management of Street Trees (도시 가로수 관리 품셈 개선에 관한 연구)

  • Do, Yoon-Taek;Han, Bong-Ho;Park, Seok-Cheol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.4
    • /
    • pp.20-36
    • /
    • 2022
  • This study aims to provide basic data for high-quality street tree management by setting reasonable management items and appropriate unit prices by reviewing the adequacy of current street tree management. Currently, street tree management items, except for street tree pruning, use general landscape tree quantity per unit for the street tree management quantity per unit. KEPCO (Korea Electric Power Corporation) applied pruning items from standard electric production infrastructure and carried out the activities at an average unit price of 51% lower for heavy pruning and 39% lower for light pruning than the standard estimate. This was judged to be a level that could not maintain or increase the quality of street tree management. It was determined that an appropriate standard unit price for street tree management was necessary. To improve the quantity per unit for the proper management of street trees, it was necessary to review costs in the field. However, due to the absence of data on actual construction costs in the domestic landscape field, detailed items of the US RSMeans Building Construction Cost Data (RSMeans) were reviewed, and the actual construction costs were calculated by applying personal domestic expenses. As a result, the standard of the estimated unit showed a good ratio of 107% for heavy pruning of street tree pruning compared to the actual construction cost, but light pruning was underestimated with a 59% ratio. Shrub pruning was 82%, weeding was 92%, tree fertilization was 87%, and windbreak wall installation was 91% under-engineered. In addition, it was also confirmed that the watering by sprinkler trucks and chemical spraying were over-designed compared to the actual construction cost at the rates of 118% and 124%, respectively. Due to the specificity of the street trees, the increase in personal expenses and the input cost of equipment, such as road safety controls, were judged to be the main cause of the underestimation of items. Therefore, it is necessary to add items related to street trees and general landscape trees to the landscape maintenance items of the standard of the estimated unit.

A Study on the Current Fire Insurance Subscription and Solutions for Ensuring the Safety of the Traditional Market (전통시장 안전성 확보를 위한 개선방안: 화재보험 가입실태를 중심으로)

  • Kim, Yoo-Oh;Byun, Chung-Gyu;Ryu, Tae-Chang
    • Journal of Distribution Science
    • /
    • v.9 no.4
    • /
    • pp.43-50
    • /
    • 2011
  • Concerning the risk factors of the outbreak of a fire in a traditional market, most of those markets are located in downtown areas or residential areas; thus, although their location may be favorable in terms of marketability, they face a potential risk in that a fire may develop into a large blaze owing to poor environment or the absence of facilities prepared for disaster during a fire. Moreover, as many people are densely poised in the markets, it is very probable that a fire may occur owing to the excessive use of heaters in the winter as well as the reckless use of electric and gas facilities. It seems that traditional markets encounter difficulty being insured against fire, because of their vulnerability and that the vast majority of small-scale sellers are likely to suffer mental anguish and tremendous physical injury in case of a fire. However, most of those sellers in the traditional markets are hand-to-mouth sellers, and they lack awareness of safety concerns and have insufficient experience in safe facility management. As small-scale sellers constitute the majority in the traditional market, the subscription rate of fire insurance in most of the traditional markets is low for the reasons of their needy circumstances and their financial burden. Statistically, the subscription by street vendors is non-existent; therefore, these vendors have a fairly limited access to indemnification after fire damage. Because of these problems, this study's purpose is to identify the current level of insurance subscription by these markets, which are exposed to poor facilities and vulnerability to fire. In order to fix this, it appears that shop owners and consumers will have to band together. For this study, we executed a fire policyholder fact-finding mission at traditional markets with approximately 108 and 981 stores. The research method was executed by an investigation using one-on-one individual interviews using a questionnaire. The contents investigated current insurance subscriptions. The method of analysis looked at the difference of insured amount according to volume size through cross-tabulation of the difference of insured amount by possession form, difference of insured amount by market form, difference of insured amount by category of business, difference of insured amount by market size, etc. Furthermore, the study should be used to propose solutions for problems through theoretical review with the use of a literature research, because the field case study was through interviews with the persons concerned, and the survey of the current insurance subscriptions by traditional market shopkeepers. The traditional market would generally have difficulty affording fire insurance. Fire insurance subscription rates of most of the market proved to be inactive, because of the economic burden of payment. Lack of funds is thought to be the main factor that causes a lack of realization about the necessity of fire insurance. In addition to expensive insurance premiums, sometimes, the companies' valuation of the businesses is lower than their actual valuations, and they do not pay out enough during a claim. The research presents an improvement plan that, when presented at the traditional markets, may strengthen their ability to procure fire insurance through the help of the central government. Researchers connected with the traditional market mainly accomplish the initial research. However, although this research has its limitations, it offers considerable benefits. For future researchers, I would suggest looking at several regions for comparison.

  • PDF