• Title/Summary/Keyword: Electric Range

Search Result 1,652, Processing Time 0.027 seconds

Design Controller For Rapidity Temperature Measurement-system (넓은 영역의 온도범위를 가지는 급속 온도특성측정시스템 컨트롤러 설계)

  • 신광식;정완영
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.33-36
    • /
    • 2001
  • An automatic TCXO frequency-temperature test apparatus was firstly developed by using thermoelectric device may. The developed system swing stably the test temperature range from -40$^{\circ}C$ to +80$^{\circ}C$ for about 1 hour The rising temperature ratio was fairly linear with time in this test temperature range. The temperature could be controlled error in error range of ${\pm}$0.05$^{\circ}C$ in this system. The frequency-Temperature properties of TCXO or the thermoelectric properties of other electric device.

  • PDF

A study on the optimum condition of electric snow melting and deicing system for the anti-freezing testing road (시험 선로 결빙 방지를 위한 전기 가열식 융설 및 융빙 시스템의 최적 조건에 관한 연구)

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.4
    • /
    • pp.362-369
    • /
    • 2008
  • The snow melting system by electric heating wires which is adopted in this research is a part of road facilities to keep surface temperature of the road higher than freezing point of water for melting the snow accumulated on it. The electric heating wires are buried under paved road at a certain depth and operated automatically and manually. Design theory, amount of heating, and installation standard vary according to economic situation, weather condition, installation place and each country applying the system. A main purpose of this study is figuring out the appropriate range of required heat capacity and installation depth and pitch for solving snowdrifts and freezing problems with minimum electric power consumption. This study was performed under the ambient air temperature($-2^{\circ}C$, $-5^{\circ}C$), the pitches of the electric heating wires(200 mm, 300 mm), heating value($250\;W/m^2$, $300\;W/m^2$, $350\;W/m^2$).

A Study on Causes and Measures Against Occurrence of Circulating Current in catenary (전차선로 순환전류 발생원인과 대책에 관한 연구)

  • Han, Hag-Su;Min, Kyung-Yun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.816-823
    • /
    • 2007
  • Electric car tract plays the role of supply high electric power to the electric car from the substation by using Pantograph of the electric car. It is always exposed to the external atmosphere, which results in quite substantial fluctuations in current and voltage during operation of electric car. This generates possibility of occurrence of accident at all times. Since range of wiring metallic globe installed on the catenary cannot achieve complete electrical contact, accidents are occurring due to circulating current caused by arc caused by incomplete contact due to occurrence of hairline fracture of Pantograph due to pressure or vibration of wiring. Furthermore, rapid increase in the operational current due to increase in the operational frequency of the electric car is causing erosion and short circuit of the metallic globe at the contact points. This study on arc is generated as current transmitted out of the substation courses through power line or wiring metallic globe other than the main circuit as the current is being collected at the electric car through feeder and feeder divergence device. Accordingly, since heat generated by the arc becomes the cause for generation of circulating current due to melting of metal or softening of metal due to increase in temperature accompanying increase in contact resistance, this research shall describe causes and measures against occurrence of circulation current.

  • PDF

Advances on heat pump applications for electric vehicles

  • Bayram, Halil;Sevilgen, Gokhan;Kilic, Muhsin
    • Advances in Automotive Engineering
    • /
    • v.1 no.1
    • /
    • pp.79-104
    • /
    • 2018
  • A detailed literature review is presented for the applications of the heat pump technologies on the electric vehicles Heating, Ventilation and Air Conditioning (HVAC) system. Due to legal regulations, automotive manufacturers have to produce more efficient and low carbon emission vehicles. Electric vehicles can be provided these requirements but the battery technologies and energy managements systems are still developing considering battery life and vehicle range. On the other hand, energy consumption for HVAC units has an important role on the energy management of these vehicles. Moreover, the energy requirement of HVAC processes for different environmental conditions are significantly affect the total energy consumption of these vehicles. For the heating process, the coolant of internal combustion (IC) engine can be utilized but in electric vehicles, we have not got any adequate waste heat source for this process. The heat pump technology is one of the alternative choices for the industry due to having high coefficient of performance (COP), but these systems have some disadvantages which can be improved with the other technologies. In this study, a literature review is performed considering alternative refrigerants, performance characteristics of different heat pump systems for electric vehicles and thermal management systems of electric vehicles.

Design of a CubeSat test platform for the verification of small electric propulsion systems

  • Corpino, Sabrina;Stesina, Fabrizio;Saccoccia, Giorgio;Calvi, Daniele
    • Advances in aircraft and spacecraft science
    • /
    • v.6 no.5
    • /
    • pp.427-442
    • /
    • 2019
  • Small satellites represent an emerging opportunity to realize a wide range of space missions at lower cost and faster delivery, compared to traditional spacecraft. However, small platforms, such as CubeSats, shall increase their actual capabilities. Miniaturized electric propulsion systems can provide the satellite with the key capability of moving in space. The level of readiness of miniaturized electric propulsion systems is low although many concepts have been developed. The present research intends to build a flexible test platform for the assessment of selected small propulsion systems in relevant environment at laboratory level. Main goal of the research is to analyze the mechanical, electrical, magnetic, and chemical interactions of propulsion systems with the modern CubeSat-technology and to assess the performance of the integrated platform. The test platform is a 6U CubeSat hosting electric propulsion systems, providing mechanical, electrical and data interfaces, able to handle a variety of electric propulsion systems, thanks to the ability to regulate and distribute electric power, to exchange data according to several protocols, and to provide different mechanical layouts. The test platform is ready to start the first verification campaign. The paper describes the detailed design of the platform and the main results of the AIV activities.

Electrical conduction phenomena of $C_{22}$--quinolium(TCNQ) langmuir-blodgett films under the high-electric field ($C_{22}$-quinolium(TCNQ) LB막의 고전게 전기전도 현상)

  • 신동명;김태완;홍언식;송일식;유덕선;강도열
    • Electrical & Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.138-144
    • /
    • 1994
  • Electrical conduction phenomena of $C_{22}$-quinolium(TCNQ) Langmuir- Blodgett(LB) films are reported through a study of current-voltage(I-V) characteristics along a perpendicular direction. The I-V characteristics were investigated by applying a step or a pulse voltage to the specimen as well as changing temperatures in the range of 20-250[.deg. C] It show an ohmic behavior in low-electric field, and a nonohmic behavior in high-electric field. This nonohmic behavior has been interpreted in terms of a conduction mechanism of space-charge limited current and Schottky effect. When the electric field is near the strength of 10$_{6}$ V/cm, there occur anomalous phenomena similar to breakdown. When step or pulse voltage is applied, the breakdown voltage shifts to the higher one as the step or pulse time width becomes shorter. To see the influence of temperature, current was measured as a function of temperature under the several bias voltages, which are lower than that of breakdown. It shows that the current increases to about 103 times near 60-70[.deg. C], and remains constant for a while up to around 150[.deg. C] and then suddenly drops. We have also performed a DSC(differential scanning calorimetry) measurement with $C_{22}$-quinolium(TCNQ) powder in the range of 30-300[.deg. C]. These results imply that the anomalous phenomena occuring in the high electric field are caused by the electrical and internal thermal effect such as a joule heating.ating.

  • PDF

Phase Transformation and Dielectric Relaxation in $Pb(Mg_{1/3}Nb_{2/3})O_3-PbTiO_3$ Relaxor Ferroelectrics (완화형 강유전체 $Pb(Mg_{1/3}Nb_{2/3})O_3-PbTiO_3$계에서의 상전이 및 Relaxation 거동)

  • Park, Jae-Hwan
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.10
    • /
    • pp.953-957
    • /
    • 2001
  • To study various relaxation phenomena of $Pb(Mg_{1/3}Nb_{2/3})O_3$ relaxor ferroelectrics, weak electric-field properties as well as strong electric-field properties were investigated in the frequency range from 1 Hz to 100 kHz. The temperature dependence of the dielectric properties were measured under the low electric-field of 1 V/mm in the phase transition temperature range from $-40^{\circ}C$ to $90^{\circ}C$. The dielectric properties obtained from the slope of the dielectric hysteresis loop and the temperature dependence of the pyroelectric properties were also investigated. When fitting all the experimental data with the Vogel-Fulcher relation, experimental data were agreed with the equation closely. Thus, dielectric relaxations could be modeled by the Vogel-Fulcher relation not only for the low electric-field but also for the high electric-field.

  • PDF

A Study on Rotor Shape Design to Reduce Torque Ripple and Core Loss of IPMSM for SEV (SEV용 IPMSM의 토크리플 및 철손 저감을 위한 회전자 형상 설계에 관한 연구)

  • Jeong-In Kang;Tae-Uk Jung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.327-332
    • /
    • 2023
  • As interest in eco-friendly and fuel-efficient electric vehicles has increased globally, there has also been a growing interest in the efficiency, vibration, and noise of motors for electric vehicles Electric vehicles generally have significantly lower driving ranges per charge compared to the maximum driving range per fueling of internal combustion engine vehicles. Additionally, there are issues with various vibrations and noise generated by the motor that can cause discomfort for passengers. Therefore, research is necessary to reduce losses, vibration, and noise of the motor to improve the driving range of electric vehicles. IPMSM with a purchased design can obtain additional reluctance torque by utilizing the difference in inductance between the d and q axes. However, due to this reluctance torque, torque ripple occurs larger than other motors. The increase in torque ripple also increases noise and vibration. Since the reluctance torque, which is the main cause of torque ripple, is determined by the shape of the motor components, torque ripple can be reduced through shape optimization. In this paper, a rotor shape for reducing torque ripple and core loss that causes vibration, noise, and efficiency to decrease of IPMSM for electric vehicles was proposed. Optimization design was carried out by changing the shape of the q-axis path of the rotor to reduce the difference in inductance of the d and q-axis of the rotor. Finally, in order to verify the validity of the design variables derived through the optimal design, the original model and the improved model were compared through the FEM. Compared to the original model, the improved model's torque verifying ripple was reduced by about 62% and core loss was reduced by about 29%, the superiority of the improved model.

A comparison of resident's behavior of operating air conditioner according to the charge for electric (사용자의 전기요금 부담 여부에 따른 여름철 냉방기 사용 특성의 비교)

  • Kwon, Suh-Hyun;Choi, Yoo-Rim;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.301-305
    • /
    • 2006
  • An electrical bill is one of the various factors that influence on energy use of residents. This study focused on electrical bills and searched that whether electrical bills affect resident behavior of operating air conditioner and their controlled indoor climate. We surveyed two groups for field study ; the one is residents who live in a studio apartment in Seoul and they are charged for electric as energy consumption they used, and the other is residents who live in a university dormitory and they are not charged for their energy consumption. We measured how long they used the air conditioner for cooling, on/off temperature of air conditioner and room temperature for these two groups. Residents were interviewed about their cooling needs, decisions about when to turn on their air conditioner and so on. We found that dormitory group has much amount of time used the air conditioner than studio apartment group and there are differences of room temperature between two groups when they turn on or off air conditioner. The result shows that perception of money affects resident behavior of operating air conditioner and their acceptable thermal range.

  • PDF

A Study on Visibility Impairment Impact of the Plume from a Vast Point Source (거대 점 오염원의 플룸에 의한 시정 장애 효과 연구)

  • 배주현;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.599-611
    • /
    • 1999
  • Now that the plume of point source was suspected to have strong impact on visibility impairment in Pusan, we evaluated visibility impairment impact of the pulme from Pusan Thermo Electric Power Plant in Pusan. Level-1 and-2 analyses were carried out using VISCREEN(Visual Impact Screen model). The emission rates for this Pusan Thermo Electric Power Plant was projected to be 116g/s of nitrogen oxides(as $NO_2$). The source fails the level-1 test with a Plume perceptibility(ΔE) of 30, nearly 15 times the screeing threshold. To characterize worstcase meteorological conditions for level-2 screening, we obtained meteorological data from Mar., 1996 to Feb., 1997 of Pusan Thermo Electric Power Plant. The source fails the level-2 test with a ΔE of 17, nearly 8.5 times the screening threshold. These analyses indicated that adverse visibility impairment could not be ruled out. Therefore a Level-3 analysis was performed using PLUVUE II(Plume Visibility model). As a result, maximum reduction of visual range for 0900LST in winter was 0.9%. Visual impact of the plume from vast point source was judged to be considerable in terms of background visibility of urban area.

  • PDF