• 제목/요약/키워드: Electric Railway Depot

검색결과 6건 처리시간 0.023초

4단자 회로망 모델을 이용한 전기철도 차량기지의 전압불평형 해석 (Analysis of Voltage Unbalance in the Electric Railway Depot Using Two-port Network Model)

  • 창상훈;오광해;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권5호
    • /
    • pp.248-254
    • /
    • 2001
  • The traction power demand highly varies with time and train positions and the traction load is a large-capacity current at single phase converted from 3-phase power system. Subsequently, each phase current converted from 3-phase power system cannot be maintained in balance any longer and thus the traction load can bring about imbalance in three-phase voltage. Therefore, the exact assessment of voltage unbalance must be carried out preferentially as well as load forecast at stages of designing and planning for electric railway system. The evaluation of unbalance voltage in areas, such as electric railway depots should be a prerequisite with more accuracy. The conventional researches on voltage unbalance have dealt with connection schemes of the transformers used in ac AT-fed electric railroads system and induced formulas to briefly evaluate voltage unbalance in the system(3). These formulas are still being used widely due to their easy applicabilities on voltage unbalance evaluation. Meanwhile, they don't take into account detailed characteristics of ac AT-fed electric railroads system, being founded on some assumptions. Accordingly. accuracy still remains in question. This paper proposes a new method to more effectively estimate voltage unbalance index. In this method, numerous diverted circuits in electric railway depots are categorized in three components and each component is defined as a two-port network model. The equivalent circuit for the entire power supply system is also described into a two-port network model by making parallel and/or series connections of these components. Efficiency and accuracy in voltage unbalance calculation as well can be promoted by simplifying the circuits into two-port network models.

  • PDF

직류철도 급전계통의 안전성 향상을 위한 차단기 동작 최적 설정의 실험적 고찰 (An Experimental Study on Operation Setting Optimization of Circuit Breaker for Improving Safety on DC Railroad Feeder System)

  • 이재봉;정노건;김재문
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.526-531
    • /
    • 2016
  • This paper presents an experimental study on the optimal settings for the selected DC fault relay (50F) to improve the operating performance for the high-speed circuit breaker on DC feeding system which ensure safety within rolling stock maintenance depot. In this study, current supplied to overhead contact wire was calculated on 1 ms interval to analyze the correction values of DC fault selective relay for the operation of current supply cutout. Particularly, standards for the accurate detection of accidents between an electric railway vehicle and the electric power facilities are shown by investigating the optimal correction values for detection of fault current, and the results indicated that it takes about 213 ms for the DC fault selective relay(50F) to fully open. In the future, the correction values of DC fault selective relay suggested in this paper will be used as the reference values of protective relay for the safe operation of DC electric railroad system such as urban railway.

직류철도차량에 대한 자계측정 및 분석 (Measurement and Analysis of Electromagnetic field for DC electric railway train)

  • 장동욱;김민철;이장무;한문섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1637-1639
    • /
    • 2005
  • The measurement of magnetic field is performed about DC and AC magnetic field in test track of depot. The test point is cap, on the converter/inverter box, on the traction motor, on the APSE and on the line filter, the height of measurement is bottom and 50 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through RS-232C and notebook PC. The DC magnetic field is measured by using the Hall Probe, test result is saved and analysis by PXI system. On the line filter, the maximum value is 1.4 mT in case of DC magnetic field and 0.044 mT in case of AC magnetic field at 50 Hz.

  • PDF

강체전차선을 이용한 직류전기철도용 이동식 전차선 시스템 개발 및 성능검증에 관한 연구 (Research on Development and Evaluation Tests of Movable Catenary System Using Rigid Bar for DC Feeding System)

  • 박성희;장동욱;강승욱
    • 한국철도학회논문집
    • /
    • 제20권3호
    • /
    • pp.356-364
    • /
    • 2017
  • 전기철도 차량은 검수를 위한 단계가 복잡하며, 안전사고에 대한 위험도 내포하고 있다. 이동식 전차선 시스템은 복잡한 과정의 검수고 입환 시스템에 대해 단순화가 가능하도록 하며, 사용자 편의성을 제공하고 안전성을 확보한다는 측면에서 매우 유용한 시스템이다. 본 논문에서는 기존 이동식전차선 대비 사용상 장점이 있고 국내 직류 시스템에 첫 적용되는 강체전차선을 적용하여 기계적인 내구성, 편의성, 작업자 안전성을 확보한 철도차량용 이동식 전차선 시스템에 대해 성능평가 및 연구개발 결과를 정리를 포함하여 현장설치를 위한 기본적인 특성을 종합적으로 분석하였다. 결론적으로 반복적인 사용 환경에 대한 내구성, 기계적인 하중에 대한 내구성, 안전성 등 요구 사양에서 우수한 결과를 나타내었다.

급곡선 분기기에서 발생한 전동열차 탈선사고의 원인분석 (Cause analysis of the electric train derailment occurred in turnout on a sharp curves.)

  • 이승원;우관제;정찬묵
    • 한국도시철도학회논문집
    • /
    • 제6권4호
    • /
    • pp.411-416
    • /
    • 2018
  • 급 곡선상에 분기기를 부설하여 운용하는 것은 일반적으로 열차안전에 바람직하지 않으나, 직선을 확보할 만큼 충분한 공간을 확보할 수 없는 산악지역이나 차량기지에서는 제한적으로 선로 곡선 부에 분기기를 설치하는 때도 있다. 본 연구에서는 급 곡선상 분기기에서 실제로 발생한 열차탈선사고의 원인을 분석하기 위하여 사고가 발생한 위치에서 측정한 선로 데이터와 사고 차량의 데이터들을 이용하여 탈선해석을 수행하였다. 탈선해석결과 곡선 선로의 분기기 시작점에서 탈선계수 값이 최대가 되며 그 크기도 1.37로써 탈선을 유발할 정도로 큰 것으로 나타났으며, 이는 실제 탈선사고가 발생한 현장조사 결과와 일치함을 알 수 있었다.

새마을 동차의 연장사용과 간선형 EMU도입간 경제성분석 (An economical analysis between extension use of PP and introduction of intercity EMU)

  • 박수명;윤동희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.775-783
    • /
    • 2010
  • 새마을 동차를 유지보수하는 용산기지의 이전에 따른 새마을 동차를 유지보수 할 기지가 없어, 현재 내구연한 20년인 새마을동차의 조기폐차가 논의 되고 있지만, 철도차량의 도입에 많은 비용이 소요되고, 정확한 정책판단이 요청되어 경제성 분석을 시행하였다. 분석을 위해 기존의 PP동차를 조기 폐차하는 경우와 신규간선형 EMU를 도입하는 경우, 철도차량정밀진단을 통해 PP동차를 내구연한을 초과하여 사용하는 경우를 시나리오 설정을 통해서 경제성분석을 시도하였다. 경제성 분석을 위해서 크게 유지보수비, 운영비, 차량감가상각비(차량 잔존가액)와 조기폐차에 따른 부대적인 비용을 산정하여 분석하였다. 특정한 철도공사의 사례이지만, 디젤차량과 전기차량의 운영비적인 측면에서 상세한 검토자료가 될 수 있다.

  • PDF