• Title/Summary/Keyword: Electric Heating Boiler

검색결과 33건 처리시간 0.02초

천연가스 사용설비 오염물질 배출특성 연구 (A Study on Characteristics of Pollutants from LNG Facilities)

  • 이중성;이현찬;유현석;한정옥
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.223-226
    • /
    • 2004
  • The thesis examined the charactcri:stlC of pollutants exhausted from LNG facilities. So, combustion gas and concentration of greenhouse gas exhausted from gas boiler for home use, furnace facilities, electric power facilities, boiler for industrial use and boiler for heating fueled LNG is measured. And the exhaust factor of pollutants is produced by classify of pollutants in detail. And this exhaust factor is compared and investigated with data of a foreign nations.

  • PDF

소형 수축열식 전기 보일러의 성능 평가에 대한 연구 (A Study on the Performance Valuation of Small Size Water Storage Electric Boiler)

  • 모종근;신재호;배철환;서정세;정한식;정효민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1524-1529
    • /
    • 2003
  • We was made 150L an water storage electric boiler and obtained various performances of the storage, radiant and keeping by experimentation, The storage performance is that the heat were off about 50 minutes after heating start, Then the temperature of outlet was arrived the stead state at $91^{\circ}C$ and the storage performances was appeared 93.64%, In the radiant performance, the water temperature was decreased from $90^{\circ}C$ to $44.8^{\circ}C$ after 960 minutes, Then the calorific value changed from 675kcal/h to 72kcal/h and the temperature decreased about 50%, The keeping performance showed mean temperature, $67.06^{\circ}C$ according to progress 800 minutes and the maximum temperature drop were $0.2^{\circ}C$, By the results of the performance valuation, the water storage electric boiler was verified fitted quality on the test prescription of KERI(Korea Electrotechnology Research Institute).

  • PDF

개별난방 공동주택의 난방 및 급탕 에너지사용량 계측 및 특성 분석 (A Measurement and an Analysis of Heating and DHW Energy Consumption in Apartment Buildings with individual Heating Systems)

  • 이수진;진혜선;김성임;임수현;임재한;송승영
    • 대한건축학회논문집:계획계
    • /
    • 제34권6호
    • /
    • pp.15-22
    • /
    • 2018
  • The purpose of this study was to suggest specific evaluation data for heating and DHW energy consumption characteristics through analyzing energy consumption measurement data of gas boiler in Apartment Buildings with individual heating systems. To do this, it was measured both gas flow and electricity for heating and DHW respectively, and then it was analyzed not only characteristics according to energy sources; gas and electricity, but also the effect of various factors on heating and DHW energy consumption. The result of this study were as follows. It was developed the electric energy estimation model of a gas boiler through analysis on patterns by energy sources. And the effective factors for heating and DHW energy consumption were demonstrated as follows: the area for exclusive use, the number of auxiliary heating equipments, the number of occupants, and the number of sanitary fixtures.

축열식 전기보일러용 마이크로프로세서 제어장치개발 (The development of microprocessor_based controller for the electrical boiler of heat storage type)

  • 김종수;박정우;조기연;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.250-253
    • /
    • 1989
  • As the necessity of increasing the midnight base load is extensively increased, electric power companies have to increase the demand of midnight electrical power by lowering the electrical charge rate at midnight. One of the most widely used midnight equipments is the heat Storage type's electrical boiler. A Single chip microprocessor controller for the heat-storage type's electrical boiler is developed. This controller call reduce the undesirable peak load at the begining of midnight (i.e.11 P.M.) time band by using backward load control method. Futhermore, this controller enables reservation of heat storge and the effective heating control the field test has been done by use the boiler for 66$m^2$ with the heater of 21KW quality.

  • PDF

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

열병합시스템 경제성 평가 프로그램의 개발 및 적용에 관한 연구 (Development and Application of an Economic Assessment Program of Cogeneration Systems)

  • 박차식;김용찬
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1547-1554
    • /
    • 1998
  • The object of this study was to develop an economic assessment program for the optimal design of the cogeneration systems composed of combining engine, generator, waste heat recovery exchanger, absorption chiller, and boiler, etc. The energy demand categorized by electric power, heating, cooling and water supply was determined by statistical data of the existing cogeneration systems. An economic assessment was performed by comparing the total cost of cogeneration system with that of non-cogeneration system. The total cost was evaluated by adding initial investment to operational cost considering efficiency of equipment, cost of equipment, fuel and electricity. To confirm the validity of the developed program, a hotel building with an area of $127,960m^2$ was selected, and the simulated results were compared with the measured data. The difference between the simulated and the measured values for the selected hotel building was approximately 12% for annual electric consumption.

난방용 보일러에서 NG-H2 혼소율에 따른 열 및 공해 성능의 검토 (A Study on the Thermal and Pollution Performances of the Heating Boilers with NG-H2 Mixture Ratio)

  • 서준선;김영직;박준규;이창언
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.573-584
    • /
    • 2021
  • Hydrogen is evaluated as one of the new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is CO2-free, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. However, use of electric grids is an unrealistic strategy for decarbonization for residential and commercial heating. Instead, use of H2 that utilizes city gas grid is suggested as a reasonable alternative in terms of compatibility with existing systems, economic feasibility, and accessibility. In this study, the thermal efficiency and NOx performance of the boiler according to the H2 mixture ratio and vapor humidified ratio are reviewed for a humidified NG-H2 boiler that vapor humidity to combustion air. Mixed fuel with H2 (20%) is almost similar to NG in terms of efficiency, flame temperature, and pollution performance. Thus, it is expected to be directly compatible with the existing NG system. If the exhaust temperature of the H2 boiler is lowered to around 60℃ at a humidified ratio of 15-20%, the NOx emission concentration can be suppressed to about 5-10 ppm. The level of efficiency reaches 87% of the rated load efficiency, which is equivalent to the highest grade achievable.

전력선 통신을 이용한 난방용 솔레노이드밸브 제어에 관한 연구 (A Study on the Control of Solenoid Valve for Heating by using Power Line Communication (PLC))

  • 신관우;김용태;이윤섭
    • 제어로봇시스템학회논문지
    • /
    • 제9권8호
    • /
    • pp.647-650
    • /
    • 2003
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance, and selective possibility of frequency property. We designed the boiler temperature control system unit by using the PLC modem. We can avoid unnecessary heating of separate temperature control unit, and save the cost accordingly control stability of the proposed system is proven through the experiment.

고설 딸기 관부 난방시스템의 에너지 절감 효과 (Energy Saving Effect for High Bed Strawberry Using a Crown Heating System)

  • 문종필;박석호;권진경;강연구;이재한;김형권
    • 생물환경조절학회지
    • /
    • 제28권4호
    • /
    • pp.420-428
    • /
    • 2019
  • 본 연구에서는 고설 딸기 관부(크라운부) 난방시스템을 전기 온수 보일러, 축열조, 순환 펌프, 관부난방 배관(백색 연질 PE관, 관경 16mm) 및 온도 제어반으로 구성하였다. 관부(크라운부) 난방의 경우 난방 배관을 딸기 관부에 최대한 밀착될 수 있도록 설치하고 배관 위치를 원예용 고정핀으로 고정하였다. 또한 관부 난방시스템의 에너지 효율을 증진하기 위해 축열조 온수 온도를 $20{\sim}23^{\circ}C$, 관부 온도를 $13{\sim}15^{\circ}C$로 관리하였다. 관부난방은 전기 온수보일러를 이용하여 $20{\sim}23^{\circ}C$의 온수를 축열조에 저장하고 순환펌프를 제어하기 위한 온도 센서를 딸기의 관부에 최대한 근접하여 설치하고 온도를 감지함으로써 관부(크라운부)를 집중적으로 난방하는 방식이다. 시험 온실의 난방 처리는 공간 난방 $4^{\circ}C$ + 관부난방(처리 1), 공간 난방 $8^{\circ}C$ (대조구), 공간 난방 $6^{\circ}C$ + 관부난방(처리 2)로 처리하였다. 각 난방처리는 온실 1동에 딸기를 980주를 심었으며, 재배방법은 표준재배법에 준해서 재배하였다. 난방 에너지 소비에 대한 비교시험은 2017년 11월 8일부터 2018년 3월 30일까지 수행되었다. 소비된 누적 전력량은 등유 사용량으로 환산하였고, 등유 소비량은 공간난방 $8^{\circ}C$(대조구)의 경우 1,320L(100%), 공간난방 $4^{\circ}C$ + 관부난방의 경우 928L(70.3%), 공간난방 $6^{\circ}C$ + 관부난방의 경우 1,161L (88%)로 계측되었다. 공간난방 $4^{\circ}C$ + 관부난방(처리 1) 및 공간난방 $6^{\circ}C$ + 관부난방(처리 2)은 $8^{\circ}C$ 공간난방(대조구)에 비해 생육 저하, 수확시기의 지연 등이 없이 비슷하게 딸기 수확이 가능하였으며, 29.7% 및 12%의 난방 에너지가 절감되는 것으로 분석되었다.

온수배관을 이용한 시설딸기 부분난방기술 개발 (Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe)

  • 문종필;강금춘;권진경;백이;이태석;오성식;남명현
    • 한국농공학회논문집
    • /
    • 제58권5호
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.