• Title/Summary/Keyword: Electric Fields

Search Result 1,155, Processing Time 0.026 seconds

Characteristics of Time-Changing Electric and Magnetic Fields at a High Voltage Laboratory (고전압 실험실에서 시변성 전자계의 특성)

  • 이복희;이경옥;안창환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.1
    • /
    • pp.83-93
    • /
    • 1997
  • This paper deals with measurements and evaluation of the time-changing electric and magnetic fields at a high-voltage laboratory. The electromagnetic disturbances originate mainly from ground faults and on/off operations of electric power equipments. The electronic circuits and control devices are very sensitive to electromagnetic interferences. It is necessory to evaluate the levels of interferences for a given electromagnetic environment. The electric field was observed by the electric field sensor having the bandwidth of the range from 40 Hz to 200 MHz, and the time-changing magnetic field was measured by the loop sensor of which the output is directly proportional to the incident signal. Also, the frequency components of the time-changing electric and magnetic fields induced by an oscillatory transient current and a chopped impulse voltage were analyzed by terms of the fast Fourier transformation, and those give the information about the levels of the electromagnetic interferences and the design of the electromagnetic shielding enclosures.

  • PDF

Diffusive-Thermal Instability and Buoyancy-Driven Instability in Laminar Attached Free-jet Flames with DC Electric Fields (직류 전기장을 인가한 층류부착화염에서 물질-열 확산 및 부력에 의한 화염진동 비교에 관한 연구)

  • Han, Jong-Kyu;Yoon, Sung-Hwan;Park, Jeong;Yun, Jin-Han;Gil, Sang-In;Seo, Sang-Il;Kim, Young-Ju
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.3
    • /
    • pp.41-51
    • /
    • 2011
  • In this paper, we describe the behavior of two self-excitations in laminar attached free-jet flames under the influence of DC electric fields, one of buoyancy-driven and the other of diffusion-thermal instability, established from the horizontal and vertical injection. In the horizontal injection with removed buoyancy effect, oscillating flames with the frequency of 1.3 - 7.4 Hz were observed in a certain condition with Lewis number more than unity. On the other hand, it was appeared Lewis number induced self-excitation as well as buoyancy-driven self-excitation in the vertical upward injection with DC electric fields. This behavior had frequency range of 1.6 - 9.4 Hz and was exhibited to attribute the buoyancy effect. Finally, a well-defined division about two self-excitations having similar frequency range is briefly discussed.

A Study on the Biofouling Control in Membrane Processes Using High Voltage Impulse (고전압 임펄스를 적용한 막분리 공정에서의 생물막 오염 제어에 관한 연구)

  • Lee, Ju-Hun;Kim, Jun-Young;Yi, Chin-Woo;Lee, June-Ho;Chang, In-Soung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.67-75
    • /
    • 2011
  • Although membrane technologies are widely applied to the water and wastewater treatment processes, strategy for the control of membrane biofouling is strongly required. In this study, a possibility of control of membrane biofouling using HVI(High Voltage Impulse) was verified based on the inactivation of microorganisms by the HVI. The HVI system was consisted of power supply, voltage amplifier, impulse generator and disinfection chamber and the model microorganism was E. coli. When 15[kV/cm] of electric fields was applied to the E. coli solution, inactivation of the microorganism was found. A possibility of the control of membrane biofouling using HVI was verified with experiments of membrane filtration with and without exposure of the HVI to biomass solution. Another membrane filtration experiments with the contaminated membranes by E. coli solution were carried out and indicate that the HVI could be used as an alternative method for membrane biofouling control. A series of simulation of the electric fields between electrodes and microorganisms was carried out for the visualization of the disinfection that showed where the electric fields are formed.

Design of the Cross Sectional Shape of Intermediate Die for Shaped Drawing of Spline (스플라인 이형인발을 위한 중간 다이 단면형상 설계)

  • Lee, J.E.;Lee, T.K.;Lee, S.K.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.17 no.8
    • /
    • pp.627-632
    • /
    • 2008
  • The cross sectional shape of intermediate die is one of important parameters to improve dimensional accuracy of final product in shaped drawing process. Until now, it has been designed by the experience or trial and error of the expert. In this study, the cross sectional shape of intermediate die for spline shape is determined by the electric fields analysis and scale factor method. The result of the electric fields analysis and scale factor method have been compared with that of the expert method. The effects of cross sectional shape on the dimensional accuracy were investigated by using FE-simulation. And then the multi-stage shaped drawing experiments were performed to verify the results of FE-simulation. As a result, the cross sectional shape from the electric fields analysis and scale factor method had the good dimensional accuracy. These two methods can be used for the method to obtain the cross sectional shape of intermediate die in shaped drawing process.

Analysis of Electric Fields Inside GIS With Metal Impurity Using 3 Dimensional Surface Charge Method (일반 3차원 표면전하법을 이용한 금속 이물질이 유입된 GIS 내부의 전계 해석)

  • Kim, Y.J.;Min, S.W.;Kim, E.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2117-2119
    • /
    • 1999
  • In this paper, the electric fields inside GIS with metal impurity is analysed by the use of 3 dimensional Surface Charge Method. We find the metal impurity makes electric field distribution inside GIS non-uniform and causes breakdown of $SF_6$ gas in GIS.

  • PDF

Analysis of Collisional Sheath in an Argon dc Discharge (아르곤 직류방전의 충돌쉬스 구조해석)

  • Choi, Young-Wook;Lee, Hae-June
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1647-1649
    • /
    • 2003
  • The electric fields of the sheath region in an argon do discharge were measured using a laser optogalvanic spectroscopy in a pressure range from 0.88 to 10 Torr, where collisions are significant in the sheath region. The sheath width is estimated as the position where the electric field becomes zero, and the pressure dependence of the measured sheath width was obtained to be $(pressure)^{-1/3}$. The measured electric fields agree well with one-dimensional simulation results but are slightly different from collisional sheath theory in the mobility limited region.

  • PDF

Effect of Transverse Electric Fields on Fracture Behavior of Ferroelectric Ceramics (횡전기장이 강유전체 세라믹의 파괴거동에 미치는 영향)

  • Lee Jong Sik;Beom Hyeon Gyu;Jeong Kyoung Moon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.2
    • /
    • pp.120-125
    • /
    • 2005
  • Effect of transverse electric fields on fracture behavior in ferroelectric ceramics under purely electrical loading is investigated. It is shown that the shape and size of the domain switching zone depend strongly on the ratio of the transverse electric field to the coercive electric field as well as the direction of the applied electric field. Under small-scale conditions, the crack-tip mode I and II stress intensity factors induced by ferroelectric domain switching are numerically obtained. The crack kinking in ferroelectric ceramics is also discussed.

A Study on Electric Field Dispersion Techniques of Epoxy-Nanocomposites for Application of High Voltage Power Apparatus (고전압 전력기기응용을 위한 에폭시-나노콤포지트의 전기장 분산기술연구)

  • Lee, Chang-Hoon;Kim, Hyo-Chul;Cho, Young-Haw;Kim, Hyun;Jo, Sung-Choe;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.97-97
    • /
    • 2010
  • A new electric application method was developed to prepare epoxy/organoclay nanocomposite for the electrical insulation in the AC electric fields and it could be also used in the field of various viscous polymer/organoclay systems. The applied AC electric field condition was as follows; (1) inter-electrode distance: 40 mm, (2) application voltage: 3-11 kV, (3) frequency: 60~1,000 Hz, and (4) application time: 0~60 min. To characterize the epoxy/clay nanocomposite, WAXS and TEM analyses were confirmed. In order to explain how the organic modifier affects the exfoliation phenomena, a mechanism of the oscillating collision of the quaternary ammonium head was proposed and the effects of the AC voltage and frequency and the organoclay content were studied.

  • PDF

Penetrated Electric Fields and Resonant Frequencies inside Metallic Enclosure with Aperture Exited by an External Dipole Source (개구를 갖는 함체의 외부 다이폴 파원에 의한 침투전계와 공진 주파수 특성)

  • 황보승;김기채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.939-947
    • /
    • 2001
  • This paper presents the penetrated electric fields and resonant frequencies inside a metallic enclosure with aperture excited by an external dipole source. In the theoretical analysis, integral equations for the current distribution and electric field distributions on the aperture are solved by applying Galerkin\`s method of moments. The results show that the electric fields inside metallic enclosure is maximum at the near the aperture and resonant frequencies are the same as calculated of the enclosure without aperture. To verify the theoretical analysis the electric field inside enclosure and resonant frequencies are compared with the experimental results.

  • PDF

Influence of Applied Electric Fields and Drive Frequencies on The Actuating Displacement of a Plate-type Piezoelectric Composite Actuator (평판형 압전 복합재료 작동기의 작동 변위에 미치는 인가전압 및 구동주파수의 영향)

  • Goo Nam-Seo;Woo Sung-Choong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.5 s.248
    • /
    • pp.576-584
    • /
    • 2006
  • The actuating performance test of plate-type piezoelectric composite actuators having different lay-up sequences was experimentally carried out at simply supported and fixed-free boundary conditions. The actuating displacement of manufactured plate-type piezoelectric composite actuator (PCA) was measured using a non-contact laser displacement measurement system. Our results revealed that the actuating displacement with increasing applied electric field at a drive frequency of 1Hz increased non-linearly at the simply supported boundary condition whereas it almost linearly increased at the fixed-free boundary condition. On the other hand, the actuating displacement of piezoelectric composite actuator depended on the applied electric field in a drive frequency range from 1Hz to 10Hz, but its behavior was different in higher drive frequencies beyond 15Hz due to the occurrence of resonance. On the basis of the above experimental results, the bending characteristics of PCAs revealed different behavior depending on applied electric fields, drive frequencies as well as boundary conditions. Therefore, by investigating drive frequencies together with applied electric fields, actuating performance can be easily controlled and PCAs which were fabricated for this study will be sufficiently applied to pumping devices.