• Title/Summary/Keyword: Electric Fields

Search Result 1,155, Processing Time 0.029 seconds

Investigation into a Prototyping Tool for Interactive Product Design: Development, Application and Feasibility Study of MIDAS (Media Interaction Design Authoring System) (인터랙티브 제품 디자인을 위한 프로토타이핑 도구: MIDAS의 활용 사례 및 유용성 연구)

  • Yim, Ji-Dong;Nam, Tek-Jin
    • Archives of design research
    • /
    • v.19 no.5 s.67
    • /
    • pp.213-222
    • /
    • 2006
  • This paper presents MIDAS (Media Interaction Design Authoring System), an authoring toolkit for designers and artists to develop working prototypes in new interaction design projects. Field research were conducted to identify the requirements and a case study of designing new interactive products was carried out to examine the feasibility of the new tool. MIDAS provides easier ways of integrating hardware and software, to manage a wide range of electric input and output elements and to employ 3D Augmented Reality technology within conventional multimedia authoring tools, such as Director and Flash, which are popularly used by designers. MIDAS was used in case study projects of design education as well as by voluntary designers for evaluation. From the result of case studies, it was found that many design projects were successfully accomplished using MIDAS. Designers who participated in the projects reported that MIDAS not only helped them to concentrate more on ideation but also was very easy to use as they implemented the physical interface concepts without advanced engineering skills. It is expected that MIDAS can also support prototyping in interactive media an, tangible user interface development and related human computer interaction fields.

  • PDF

Evaluation of Chromosomal Alteration in Electrical Workers Occupationally Exposed to Low Frequency of Electro Magnetic Field (EMFs) in Coimbatore Population, India

  • Balamuralikrishnan, Balasubramanian;Balachandar, Vellingiri;Kumar, Shanmugam Suresh;Stalin, Nattan;Varsha, Prakash;Devi, Subramaniam Mohana;Arun, Meyyazhagan;Manikantan, Pappuswamy;Venkatesan, Chinnakulandhai;Sasikala, Keshavarao;Dharwadkar, Shahnaz N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2961-2966
    • /
    • 2012
  • Extremely low frequency electro magnetic fields (EMFs) have been classified as possibly carcinogenic to humans by the International Agency for Research on Cancer. An increased number of chromosomal alterations in peripheral lymphocytes are correlated with elevated incidence of cancer. The aim of the present study was to assess occupationally induced chromosomal damage in EMF workers exposed to low levels of radiation. We used conventional metaphase chromosome aberration (CA) analysis and the micronucleus (MN) assay as biological indicators of non ionizing radiation exposure. In the present study totally 70 subjects were selected including 50 exposed and 20 controls. Informed written consent was obtained from all participants and the study was performed in accordance with the Declaration of Helsinki and the approval of the local ethical committee. A higher degree of CA and MN was observed in exposed subjects compared to controls, the frequency of CA being significantly enhanced with long years of exposure (P<0.05). Moreover increase in CA and MN with age was noted in both exposed subjects and controls, but was significantly greater in the former. The results of this study demonstrated that a significant induction of cytogenetic damage in peripheral lymphocytes of workers occupationally exposed to EMFs in electric transformer and distribution stations. In conclusion, our findings suggest that EMFs possess genotoxic capability, as measured by CA and MN assays; CA analysis appeared more sensitive than other cytogenetic end-points. It can be concluded that chronic occupational exposure to EMFs may lead to an increased risk of genetic damage among electrical workers.

Analytical Study of Railroad Bridge for Maglev Propulsion Train with Dynamical Influence Variable (동적영향변수를 통한 자기부상열차용 철도교의 해석적 연구)

  • Yoo, Yi-Seul;Park, Won-Chan;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.532-542
    • /
    • 2018
  • Because maglev trains have a propulsion and absorption force without contact with the rails, they can drive safely at high-speed with little oscillation. Recently, test model of a maglev propulsion train was produced and operated, and has since been chosen as a national growth industry in South Korea; there have been many studies and considerable investment in these fields. This study examined the dynamic responses due to bridge-maglev train interaction and basic material to design bridges for maglev trains travelling at high-speed. Depending on the major factors affecting the dynamic effects, the scope of this study was restricted to the relationship between dynamic responses. A concrete box girder was chosen as a bridge model and injured train and rail types in domestic production were selected as the moving train load and guideway analysis model, respectively. From the analysis results, the natural frequency of a bridge for a maglev train, which has a deflection limit L/2000, was higher than those of bridges for general trains. The dynamic responses of the girder of the bridge for a maglev train showed a substantial increase in proportion to the velocities of the moving train like other general bridge cases. Maximum dynamic response of the girder is shown at a moving velocity of 240km/h and increased with increasing moving velocity of train. These results can be used to design a bridge for maglev propulsion trains and provide the basic data to confirm the validity and verification of the design code.

Culture and Ecology-Oriented City Marketing: A Case Study of Gangneung City (문화.생태를 이용한 도시마케팅 사례 연구)

  • Heo, Chung-Uk
    • Korean Business Review
    • /
    • v.22 no.2
    • /
    • pp.157-179
    • /
    • 2009
  • This papers aims to focus on the city marketing as the green growth policy strategies using a case study of Gangneung City, Republic of Korea. In the case study it was verified the fields of urban growth including ecology, culture, alternative and recycled energy, green transportation system. The implications of the study were as follows: First, the city government had regenerated the coastal pine forest through removing unlicensed buildings which were squatted down in decades. Secondly, the city government has recognized the value of culture that possessed various types of cultural asserts. Thirdly, it is possible to use and produce the ocean energy with the tidal power plant, wind power plant and green deep water because Gangneung City has the ocean-oriented image and is located the coastal region. Lastly, the city government has been utilizing the LED traffic light using solar heat and is going to apply the green car like an electric car. This paper indicates the importance of the alternatives of the green growth-oriented policy through city marketing using the concept of culture and ecology. The city government will strive after an advanced triple bottom line with the ecological sustainability, cultural diversity and economic effectiveness in the near future.

  • PDF

An Interpretive Analysis of Magnetotelluric Response for a Three-dimensional Body Using FDM (FDM을 이용한 MT 탐사의 3차원 모형 반응 연구)

  • Han Nuree;Lee Seong Kon;Song Yoonho;Suh Jung Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.2
    • /
    • pp.136-147
    • /
    • 2004
  • In this study, the characteristics of magnetotelluric (MT) responses due to a three-dimensional (3-D) body are analyzed with 3-D numerical modeling. The first model for the analysis consists of a single isolated conductive body embedded in a resistive homogeneous half-space. The second model has an additional conductive overburden while the other conditions remain the same as the first one. The analysis of apparent resistivities shows well that the 3-D effects are dominant over some frequency range for the first model. Two mechanisms, current channeling and induction, for secondary electric fields due to the conductive body are analyzed at various frequencies: at high frequencies induction is more dominant than channeling, while at low frequencies channeling is more dominant than induction. Tippers have a strong relation to the position of anomalous body and the real and imaginary parts of induction vector also indicate the position of anomalous body. off-line conductive anomaly sometimes causes severe problem in 2-D interpretation. In such case, induction vector analysis can give information on the existence and location of the anomalous body. Each parameter of the second model shows similar responses as those of the first model. The only difference is that the magnitude of all parameters is decreased and that the domain showing the 3-D effects becomes narrower. As shown in this study, the analysis of 3-D effects provides a useful and effective means to understand the 3-D subsurface structure and to interpret MT survey data.

Development of an Improved Numerical Methodology for Design and Modification of Large Area Plasma Processing Chamber

  • Kim, Ho-Jun;Lee, Seung-Mu;Won, Je-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.221-221
    • /
    • 2014
  • The present work proposes an improved numerical simulator for design and modification of large area capacitively coupled plasma (CCP) processing chamber. CCP, as notoriously well-known, demands the tremendously huge computational cost for carrying out transient analyses in realistic multi-dimensional models, because electron dissociations take place in a much smaller time scale (${\Delta}t{\approx}10-8{\sim}10-10$) than time scale of those happened between neutrals (${\Delta}t{\approx}10-1{\sim}10-3$), due to the rf drive frequencies of external electric field. And also, for spatial discretization of electron flux (Je), exponential scheme such as Scharfetter-Gummel method needs to be used in order to alleviate the numerical stiffness and resolve exponential change of spatial distribution of electron temperature (Te) and electron number density (Ne) in the vicinity of electrodes. Due to such computational intractability, it is prohibited to simulate CCP deposition in a three-dimension within acceptable calculation runtimes (<24 h). Under the situation where process conditions require thickness non-uniformity below 5%, however, detailed flow features of reactive gases induced from three-dimensional geometric effects such as gas distribution through the perforated plates (showerhead) should be considered. Without considering plasma chemistry, we therefore simulated flow, temperature and species fields in three-dimensional geometry first, and then, based on that data, boundary conditions of two-dimensional plasma discharge model are set. In the particular case of SiH4-NH3-N2-He CCP discharge to produce deposition of SiNxHy thin film, a cylindrical showerhead electrode reactor was studied by numerical modeling of mass, momentum and energy transports for charged particles in an axi-symmetric geometry. By solving transport equations of electron and radicals simultaneously, we observed that the way how source gases are consumed in the non-isothermal flow field and such consequences on active species production were outlined as playing the leading parts in the processes. As an example of application of the model for the prediction of the deposited thickness uniformity in a 300 mm wafer plasma processing chamber, the results were compared with the experimentally measured deposition profiles along the radius of the wafer varying inter-electrode gap. The simulation results were in good agreement with experimental data.

  • PDF

Assessment of Landscape Tree Vigor Using Cambial Electrical Resistance (형성층 전기저항을 이용한 조경용 수목 활력도 분석)

  • Hwang, Dong Kyu;Kim, Dong Yeob
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.302-306
    • /
    • 2016
  • There are various methods to evaluate tree vigor. Cambial electrical resistance represents tree vigor using the method of electrophysiological diagnosis. This study investigated the vigor of several tree species using Shigometer, and compared the differences among the species. The factors, such as foliation, trunk orientation and bark temperature, which affect electrical resistance were also investigated. The needle penetration into cambium was controlled to keep the depth consistent in order to minimize measurement error. Each of three trees were selected from Zelkova serrata, Ginkgo biloba, Metasequoia glyptostroboides, Pinus koraiensis, and Liriodendron tulipifera. The electrical resistances were measured at 60 and 120 cm height of the stem in 4 directions from March until May 2011. The soil conditions in surrounding areas and tree stress responses were also measured. The results were analyzed for the relationship between electrical resistance and the affecting factors. The electrical resistance showed a relatively higher level before foliation until mid-March. The values started to decline from April and recorded a minimal level on May 11. The changes of soil moisture, soil electric conductivity, and tree stress responses during the measurement period showed a similar trend to that of electrical resistance. The Pinus koraiensis, an evergreen conifer, showed few changes on the electrical resistance values during the measurement period. Zelkova serrata, Ginkgo biloba, and Metasequoia glyptostroboides showed the highest bark temperatures and lowest electrical resistances at their south-facing stem. Shigometer can provide measures simple to assess tree vigor in the fields, and to the management of trees.

Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines (고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구)

  • Jung, Joon Sig;Choi, Sung Ho;Jeon, Hyung Jin;Kim, Yoon Shin;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.353-363
    • /
    • 2014
  • The purpose of this study was to investigated the ELF-MF emission level of various environments such as 258 facilities near located to high voltage transmission lines and 120 high voltage transmission lines, 17 underground cable lines. In addition, ELF-MF reduction rate according to separation distance was calculated by using simulations. An appropriate separation distance showing below 4mG was at least 70m. In the case of the appropriate separation distance for 120 high voltage transmission lines, 154kV required 20m of separation distance and 345kV required 60m of separation distance. The simulation results showed that the appropriate separation distance showing below 4mG was 40m and 60m for overhead 154kV and 345kV respectively. To adjust the worst conditions considering the aspects of environmental impact assessment study and the electric power currents that will increase in the future, the appropriate minimum separation distance for HVTL is judged to be above 70m in this study. Thus, there is a need to establish the greenbelt or buffer zone within 70m so as to create an environment in which the receptors are not exposed and thereby eliminate the risk factors of ELF-MF against humans.

The Method of Power Domain Ontology Construction and Reasoning based on Power Business Platform (전력 비즈니스 플랫폼 기반의 전력 도메인 온톨로지 구축 및 추론 방법)

  • Hong, Taekeun;Yu, Kyungho;Kim, Pankoo
    • Smart Media Journal
    • /
    • v.9 no.2
    • /
    • pp.51-62
    • /
    • 2020
  • Starting with the "Smart Grid National Road Map" in 2010, the Smart Grid 2030 was introduced through the basic plan and implementation plan of the intelligent power grid with the goal of building the world's first national smart grid. In this paper, we intend to build a power domain ontology based on the power business platform based on the upper and lower conceptual models of the "Smart Grid Interoperability Standard Framework and Roadmap", the standard of implementation plan. Ontology is suitable for expressing and utilizing the smart grid conceptual model because it considers hierarchical structure as knowledge defines the properties of entities and relationships between entities, but there is no research related to them. Therefore, in this paper, the upper ontology was defined as a major category for smart grid-related fields, and the lower ontology was defined as detailed systems and functions for the upper ontology to construct the ontology. In addition, scenarios in various situations that could occur in the power system were constructed and significant inference results were derived through inference engines and queries.

A Study on the Controlled-source Electromagnetic Responses Incorporating the Steel Casing (시추공 케이싱을 고려한 인공송신원 전자탐사 반응 고찰)

  • Oh, Seokmin;Noh, Kyubo;Seol, Soon Jee;Byun, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.4
    • /
    • pp.216-225
    • /
    • 2017
  • Recently, steel casing became an interesting issue when applying controlled-source electromagnetic (EM) method to various fields because effects of steel casing on EM responses are not negligible. This study employed an approach that approximates the steel casing as a series of electric dipole sources in order to develop the numerical algorithm for the efficient simulation of EM responses in the presence of steel casing. After verifying the validity of the developed algorithm, we analyze effects of steel casing on EM responses with the synthetic model simulating geothermal reservoir environment. The analysis showed that the effects of steel casing on EM responses are localized near the casing and increase as the transmitter becomes close to the casing. In addition, through the analysis on the EM responses by the injection of clean water, we confirm that the effects of casing are negligible when interpreting the after-injection data acquired using the transmitter located far enough from the casing. Considering the difference in EM responses between before and after injection in inversion, the effects of the casing can be neglected although after-injection data shows considerable difference due to the close distance between the transmitter and casing. To investigate this kind steel casing effect, the precise analysis on EM responses should be preceded. The algorithm introduced in this study will contribute to the reliable calculations of EM responses distorted by the conductive steel casing.