• 제목/요약/키워드: Electric Field Utilization Factor

검색결과 20건 처리시간 0.03초

고전압 전력기기 개발을 위한 기중 절연파괴특성 분석에 관한 연구 (A Study on the Lightning Impulse Dielectric Characteristics of Air for the Development of Air-Insulated High Voltage Apparatuses)

  • 남석호;강형구
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1005-1010
    • /
    • 2011
  • The accidents caused by dielectric instability have been increasing in power grid. It is important to enhance the dielectric reliability of a high voltage apparatus to reduce the damage from electrical hazards. To develop an electrically reliable high voltage apparatus, the experimental study on the electrical breakdown field strength is indispensable, as well as theoretical approach. In this paper, the lightning impulse breakdown characteristics considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only maximum electric field intensity but also utilization factors of electrode systems. The results are expected to be applicable to designing the air-insulated high voltage apparatuses.

임펄스전압에 대한 N2가스의 절연파괴특성 (Electrical Breakdown Characteristics of N2 Gas under Impulse Voltages)

  • 신희경;김동규;이복희
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.131-136
    • /
    • 2011
  • This paper aims to examine the possibility of using an environmentally friendly $N_2$ as an alternative gas to $SF_6$. For this purpose, we have investigated breakdown characteristics of $N_2$ under impulse voltages in a quasi-uniform electric field gap. The 1.2/50[${\mu}s$] lightning impulse voltage, switching impulse voltages and oscillatory impulse voltages were applied at the test gap. The electric field utilization factor ranges from 0.5 to 0.8. The experimental data of $SF_6$ and $N_2$ acquired in the same experimental condition are presented in parallel for comparison. As a result, the breakdown voltages in $SF_6$ and $N_2$ are linearly increased with the gas pressure, also the breakdown voltages in $N_2$ are increased with increasing the gap distance and electric field utilization factor. The positive breakdown voltages are higher than the negative breakdown voltages. The nagative basic lightning impulse withstand level of 150[kV] in $N_2$ of about 0.5[MPa] is nearly equal to that in $SF_6$ of 0.15[MPa]. It is seen from the results obtained in this work that $N_2$ can be used as an eco-friendly alternative gas to $SF_6$ in distribution power equipment.

고전압 전력기기 개발을 위한 기중 임펄스절연파괴특성에 관한 연구 (Experimental study on the lightning impulse breakdown characteristics of air for the development of air-insulated high voltage apparatuses)

  • 강형구;김준연;석복렬;김동해
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1473_1474
    • /
    • 2009
  • To develop electrically reliable high voltage apparatuses, the experimental study on the electrical breakdown field strength is needed, as well as theoretical approach. In this paper, lightning impulse breakdown characteristics considering utilization factors are investigated for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using five kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only gap length but also utilization factor of electrode systems. The results are expected to be applicable to the design of high voltage apparatuses.

  • PDF

Sparkover Voltage Estimation of Standard Sphere Gaps for Negative Polarity by Calculation of Ionization Index

  • Nishikori, Yasuo;Kojima, Soji;Kouno, Teruya
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권2호
    • /
    • pp.45-50
    • /
    • 2004
  • The field utilization factor (equation omitted) (the mean electric field / the maximum electric field) of standard sphere gaps was calculated by the charge simulation method, taking into account the ground plane and shanks. n changes mainly with g/r and slightly with 1$_1$, 1$_2$ and 1, where D=2r is the sphere diameter, g is the gap length, 1$_1$ and 1$_2$, respectively, are the lengths of the upper and lower shank, and t is the shank diameter. Generally, (equation omitted) increases as 1$_1$,1$_2$ and t each becomes larger. IEC standard 60052(2002) limits t$\leq$0.2D 1$_1$$\geq$1D and prescribes A=1$_2$+D+g where A is the height of the spark point on the upper sphere. Therefore, (equation omitted) is the largest when A=9D and the smallest when A=3D. The simple equation of a straight line, (equation omitted)=1- (g/3r), can generally be used as a representative value of (equation omitted) for a wide variety of sphere diameters that are permitted by the IEC standard. The maximum electric field E$_{m}$ at sparkover of standard air gaps has also been calculated by the relation E$_{m}$=V/(equation omitted)g). E$_{m}$ describes a U-curve for g/r, up to the sphere diameter of 1 m. Moreover, for 1.5-m and 2-m diameters and especially .for negative polarity, sparkover voltages have been calculated by integration of the ionization index.index.

재활용을 고려한 HDPE/EVA필름의 전계분포 및 체적저항특성 해석 (Analysis of Electric Field Distribution and Characteristics of Volume Resistivity in HDPE/EVA Film for Recycling)

  • 이홍규;임기조;김용주
    • 한국전기전자재료학회논문지
    • /
    • 제21권9호
    • /
    • pp.801-807
    • /
    • 2008
  • Recently, CV, CN-CV and CNCV-W cable are used for HVDC transmission and distribution cable. However, XLPE which is used as insulation layer of power cable has thermosetting properties. It is very difficult to recycling. In this paper, we prepared HDPE/EVA film, which the blending ratio are 80:20, 70:30, 60:40, 50;50 respectively for the purpose of recycling. Main factor such as electric field distribution and its resistivity in insulation system affected on insulation performance and reliability for HVDC applications. Therefore, electric field distribution formed by space charge and characteristics of volume resistivity was currently investigated. We suggest the possibility of utilization for HVDC insulation layer from the results.

액체질소를 사용하는 초전도 고전압 전력기기의 절연 특성 연구 (Analytical and Experimental studies on Dielectric Characteristics of High Voltage Superconducting Machines in Liquid Nitrogen)

  • 나진배;고태국;강형구;석복렬;김태중
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.46-50
    • /
    • 2011
  • The electrical insulation design of high voltage superconducting fault current limiters (SFCLs) should be confirmed to be applied for the stabilization of the power grid. This paper describes numerical analysis and AC dielectric experiments for developing high voltage SFCLs. The electric field distributions between applied high voltage part and ground were calculated by finite element method (FEM) simulation tool and AC criterion of liquid nitrogen at 200 kPa was calculated from correlation between the field utilization factor and FEM simulation results. This paper deals with ceonceptual insulation design of a 154 kV class single-phase no-inductively wound solenoid type SFCL which was focused on gap distance between the cryostat and superconducting coils. Furthermore, the shield ring effect was confirmed to reduce maximum electric field at applied high voltage part.

이용률을 이용한 과냉질소 냉각시스템용 절연가스의 절연특성에 관한 연구 (A Study on the Dielectric Characteristics of Insulation Gases for a Sub-cooled Liquid Nitrogen System)

  • 강형구;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.52-55
    • /
    • 2010
  • A sub-cooled liquid nitrogen system is known as a promising method to develop high voltage superconducting apparatuses such as superconducting fault current limiters (SFCLs) and superconducting cables. To develop a high voltage superconducting machine adopting the sub-cooled liquid nitrogen system with a constant pressure. injecting a non-condensable gas is indispensable. In this study. the dielectric characteristics of insulation gases are investigated and analyzed by using electric utilization factors ($\xi$). It is found that the maximum electric field at sparkover that occurs with 50 % probability. $E_{MAX.50%}$ exponentially decreases as the S increases. This means that the $E_{MAX.50%}$ at sparkover can be estimated with the $E_{MAX.50%}$

액체질소 내에서 뇌 임펄스전압에 대한 압력별 GFRP의 절연파괴 특성 분석 (A Study on the Dielectric Characteristics of GFRP in LN2 under Lightning Impulse Voltage According to Pressure)

  • 홍종기;허정일;남석호;강형구
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1471-1476
    • /
    • 2012
  • A study on the dielectric characteristics of the Glass Fiber Reinforced Plastic (GFRP) is important for designing a reliable high voltage superconducting machines such as transmission superconducting fault current limiters, superconducting cables, and superconducting transformers. In this paper, dielectric experiments of the GFRP under lightning impulse voltage are conducted in liquid nitrogen($LN_2$) according to various experimental conditions such as the thicknesses of the GFRP, the diameters of electrode systems and the pressures. The dielectric characteristics of the GFRP are analyzed by using a Finite Elements Method(FEM) according to various field utilization factors. It has been reported that the electrical insulation design of the GFRP would be conducted by considering the mean electric field intensity($E_{mean}$) distributed inside the GFRP. In this study, it is found that the dielectric performance of the GFRP could be explained by not only $E_{mean}$ but also the maximum electric field intensity ($E_{max}$). Finally, the empirical formulae of the GFRP to estimate an electrical breakdown voltage at sparkover under the lightning impulse condition are deduced. It is expected that the presented experimental results in this paper are helpful to design electrically reliable high voltage superconducting machines using the GFRP as an insulation material.

과냉질소 냉각시스템 가압용 기체의 절연내력특성 분석 (Analysis on the Dielectric Characteristics of Various Insulation Gases for Developing a Sub-cooled Liquid Nitrogen Cooling System)

  • 강형구;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.27-30
    • /
    • 2011
  • A sub-cooled liquid nitrogen cooling system is known as a most promising method to develop large scale superconducting apparatuses such as superconducting fault current limiters and superconducting cables [1]. Gaseous helium (GHe), gaseous nitrogen ($GN_2$) and sulfur hexafluoride ($SF_6$) are commonly used for designing an high voltage applied superconducting device as an injection gaseous medium [2, 3]. In this paper, the analysis on the dielectric characteristics of GHe, $GN_2$ and $SF_6$ are conducted by designing and manufacturing sphere-to-plane electrode systems. The AC withstand voltage experiments on the various gaseous insulation media are carried out and the results are analyzed by using finite element method (FEM) considering field utilization factors (${\xi}$). It is found that the electric field intensity at sparkover ($E_{MAX}$) of insulation media exponentially decreases according to ${\xi}$ increases. Also, the empirical expressions of the functional relations between $E_{MAX}$ and ${\xi}$ of insulation media are deduced by dielectric experiments and computational analyses. It is expected that the electrical insulation design of applied superconducting devices could be performed by using the deduced empirical formulae without dielectric experiments.

전극 간격에 따른 공기의 절연파괴 특성에 관한 연구 (A Study on the Electrical Breakdown Characteristics of Air according to Electrode Gap)

  • 강종오;이온유;김준일;방승민;이홍석;이종득;강형구
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.301-306
    • /
    • 2014
  • Recently in accordance with the rapid development of the industrial society, the accidents caused by dielectric breakdown have been increasing in power grid. It is important to prevent the dielectric breakdown of a high voltage apparatus to reduce the damage from electrical hazards. To establish an electrically reliable database of insulation design criteria for high voltage apparatus, a study on dielectric characteristics test is indispensable. In this study, dielectric characteristics according to field utilization factors (${\xi}$) which are represented as the ratio of mean electric field to maximum electric field are investigated. the dielectric breakdown experiments by using several kinds of electrode systems made with stainless steel are performed by AC breakdown voltage under air-insulation. Also, the experimental results are analyzed by the Weibull distribution. As a result, it is found that the dielectric characteristics of air-insulation are determined by ${\xi}$ as well as arrangement of electrode systems. It is considered that the results of this study would be applicable to designing the air-insulated high voltage apparatuses.