• 제목/요약/키워드: Electric Energy Management System

검색결과 318건 처리시간 0.038초

고분자전해질 연료전지 예지 진단 기술 (A Review on Prognostics of Polymer Electrolyte Fuel Cells)

  • 이원용;김민진;오환영;손영준;김승곤
    • 한국수소및신에너지학회논문집
    • /
    • 제29권4호
    • /
    • pp.339-356
    • /
    • 2018
  • Although fuel cell systems have advantages in terms of electric efficiency and environmental impact compared with conventional power systems, fuel cell systems have not been deployed widely due to their low reliability and high price. In order to guarantee the lifetime of 10 years, which is the commercialization goal of Polymer electrolyte fuel cells (PEFCs), it is necessary to improve durability and reliability through optimized operation and maintenance technologies. Due to the complexity of components and their degradation phenomena, it's not easy to develop and apply the diagnose and prognostic methodologies for PEFCs. The purpose of the paper is to show the current state on PEFC prognostic technology for condition based maintenance. For the prognostic of PEFCs, the model driven method, the data-driven, and the hybrid method can be applied. The methods reviewed in this paper can contribute to the development of technologies to reduce the life cycle cost of fuel cells and increase the reliability through prognostics-based health management system.

엘만 순환 신경망을 사용한 전력 에너지 시계열의 예측 및 분석 (The Prediction and Analysis of the Power Energy Time Series by Using the Elman Recurrent Neural Network)

  • 이창용;김진호
    • 산업경영시스템학회지
    • /
    • 제41권1호
    • /
    • pp.84-93
    • /
    • 2018
  • In this paper, we propose an Elman recurrent neural network to predict and analyze a time series of power energy consumption. To this end, we consider the volatility of the time series and apply the sample variance and the detrended fluctuation analyses to the volatilities. We demonstrate that there exists a correlation in the time series of the volatilities, which suggests that the power consumption time series contain a non-negligible amount of the non-linear correlation. Based on this finding, we adopt the Elman recurrent neural network as the model for the prediction of the power consumption. As the simplest form of the recurrent network, the Elman network is designed to learn sequential or time-varying pattern and could predict learned series of values. The Elman network has a layer of "context units" in addition to a standard feedforward network. By adjusting two parameters in the model and performing the cross validation, we demonstrated that the proposed model predicts the power consumption with the relative errors and the average errors in the range of 2%~5% and 3kWh~8kWh, respectively. To further confirm the experimental results, we performed two types of the cross validations designed for the time series data. We also support the validity of the model by analyzing the multi-step forecasting. We found that the prediction errors tend to be saturated although they increase as the prediction time step increases. The results of this study can be used to the energy management system in terms of the effective control of the cross usage of the electric and the gas energies.

사물 인터넷 기반의 1인 가구를 위한 스마트 콘센트 시스템 (Smart Outlet System for Single-person Household based on IoT (Internet of Things))

  • 김희숙;박병주;조영주
    • 디지털콘텐츠학회 논문지
    • /
    • 제18권5호
    • /
    • pp.895-904
    • /
    • 2017
  • 본 논문에서는 1인 가구를 대상으로 전기 안전, 전기 에너지 소비 관리 그리고 비상시 네트워크를 연결하여 예약된 연락처에 메시지를 전송하는 사물인터넷 기반의 스마트 콘센트 시스템 구축 방식을 제안한다. 제안된 스마트 콘센트 시스템은 서버와 모듈, 어플리케이션, WiFi AP 수신기 사이에 패킷 데이터와 프로토콜을 파싱하여 구현된다. 통신을 위해 구축된 WiFi AP는 콘센트 뿐 만 아니라 가스 차단, 도어락 등에 연결하여 사용하는 것이 가능하다. 또한 제안된 방식은 AC 전류센서(SCT-013)를 통해 받아온 해당 콘센트의 전력량을 실시간으로 수신하여 원격 모니터링 기능을 제공할 수 있다. 스마트 콘센트 시스템은 대기전력 차단 기능과 더불어 전력 사용 자동 분석을 통해 비상시 전력 자동 차단 기능까지 할 수 있을 것으로 기대한다.

EMS data 분석 및 최적화 기법을 적용한 제어지역별 목표운전전압 제안 (Target Operation Voltage Guidelines Considering Voltage Level in Each Voltage Control area by Applying Optimization Technique Through EMS Data Observation)

  • 성웅;김재원;김태균;이병준;정응수;조종만
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.671-678
    • /
    • 2009
  • This paper presents target operation voltage guidelines of each voltage control area considering both voltage stability and economical efficiency in real power system. EMS(Energy Management System) data, Real-time simulator, shows not only voltage level but lots of information about real power system. Also this paper performs optimal power flow calculation of three objective functions to propose the best target operation voltage. objective function of interchange power flow maximum and active power loss minimization stand for economical efficiency index and reactive power reserve maximum objective unction represents stability index. Then through simulation result using optimazation technique, the most effective objective function is chosen. To sum up, this paper divides voltage control area into twelve considering electric distance characteristics and estimate or voltage level by the passage of time of EMS peak data. And through optimization technique target operation voltage of each voltage control area is estimated and compare heir result. Then it is proposed that the best scenario to keep up voltage stability and maximize economical efficiency in real power system.

수직원통형 빙축열조내 외향용융과정시 열전달특성에 관한 연구 -작동유체의 유동방향 및 축열조 형상비에 따른 열성능 비교- (A study on the heat transfer characteristics during outward melting process of ice in a vertical cylinder)

  • 김동환;김동춘;김일경;김영기;임장순
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.171-179
    • /
    • 1997
  • During the day time in summer, peak of air conditing load, and electric power management system lies under overloaded condition. The reason is the enlarged peak load value of electric power caused by increased air-cooling load in summer. To prevent load concentration during day time and overloaded condition of power management system, some energy storage methods are suggested. One of these methods is ice storage system. Water has some good properties as P.C.M.(Phase Chang Material) : Its melting point is the range of required operation temperature. It has large specific latent heat and is chemically stable compared to other organic or inorganic substances. It is cheap and easy to treat. This study represents experimental results of heat transfer characteristics of P.C.M. under the outward melting process in a vertical cylinder. We experimented with twelve combinations of conditions, i.e., three different inlet temperatures($7^{\circ}C,\;4^{\circ}C\;and\;1^{\circ}C$), two working fluid directions(upward and downward), and two aspect ratios, H/R(4 and 2). At the inlet temperature of $7^{\circ}C$ and $4^{\circ}C$, there was temperature stagnation region where the temperature of P.C.M. remains constant at $4^{\circ}C$ regardless of aspect ratio and direction of working fluid. This temperature stagnation occurs as the water, at its maximum density, flows down to the lower region. The phase change interface formed bell-shaped curve as the melting process continued. With a new set of conditions(4H/R, inlet temperature $4^{\circ}C$ and $1^{\circ}C$, downward/upwerd inlet direction), the movement of phase change interface was faster when the working flued inlet direction was downward. With the same set of conditions, melting rate and total melting energy were larger when the working fluid inlet direction was downward. The results were reversed when the other sets of conditions were applied.

  • PDF

Development of a Novel Methodology for DC Railway Power Network Analysis Based on Participation Factor

  • Shin, Byoung-Yoon;Jang, Gilsoo;Shin, Seung-Kwon;Joo, Sung-Kwan;Lee, Hansang
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.478-485
    • /
    • 2017
  • Urban DC railways have played an important role in urban transportation, and railway operation and energy management have been emphasized to be important to achieve maximum efficiency from existing infrastructure. Fast, accurate DC railway power flow analysis is required to operate a DC railway efficiently, and this paper proposes a novel methodology to analyze the DC railway power network by implementing the participation factor (PF). The PF concept consists of a correlation between the vehicle and the substation, as explained using zones based on the position of the vehicles running on the route. Then, the DC railway powerflow is calculated using the PF concept. Finally, the usability of the proposed method was validated via case studies with actual railway operation data, and we discuss some of the advantages of the suggested methodology.

태양광 반사형 전동 블라인드의 제어 및 시뮬레이션 (Control and Simulation of Sun Light Reflection Electric Blind)

  • 송승관;김경주;이신호;박진배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1148_1149
    • /
    • 2009
  • 반사형 전동 블라인드는 BEMS(Building Energy Management System)에 이용되는 조명 에너지 절감 장치로서, 블라인드 날개를 반사형 재질로 제작하여, 외부 채광이 블라인드 날개에 반사되어 천장에 반사되고 반사된 빛은 천장에서 확산되어 실내 깊숙이 부드럽고 균일한 조도를 공급해 준다. 이를 이용하면, 실내 거주자의 불편함 없이 실내 인공조명 사용량을 줄일 수 있다. 이를 구현하기 위해서는 태양광선의 고도의 변화에 따라 블라인드의 제어 각도를 계산하여 블라인드 제어 전동 모터를 구동해야 한다. 따라서 본 논문에서는 외부 채광을 실내 천장 면에 균일하게 반사할 수 있는 블라인드 날개의 제어 각도의 최적 조건을 제시하고, 컴퓨터 시뮬레이션을 통해 제시한 블라인드 날개 각도의 최적성을 검증하였다.

  • PDF

정보가전기기 전력저감 기술 및 지능형 에너지 관리시스템 개발에 관한 연구 (Researches on technology of saving the electric power in intelligent appliance and development of the intelligent energy management system)

  • 김찬;전의석;최영길;김동현;김성철;조경숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.896-897
    • /
    • 2008
  • 홈넷기반 정보가전기기의 대기전력을 초절전칩을 적용하여 1W 이하로 줄이고, 가전기기에서 낭비되는 전력의 경로를 오토스위치를 통해 전력소모를 차단시키며, 홈플러그와 관리서버를 통해 전력낭비의 요소를 파악하여 전력소모를 저감하여 안전하고 쾌적한 홈오토메이션을 구현함으로써 인류의 행복추구를 목적으로 한다.

  • PDF

Tritium( $^3$H) Activity Measurement by the Liquid Scintillation Counting Method

  • Hwang, Sun-Tae;Oh, Pil-Jae;Lee, Min-Kie;Kim, Wi-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제10권E호
    • /
    • pp.299-302
    • /
    • 1994
  • At a nuclear power plant, environmental radioactivity monitoring is routine work for the radiation safety management For the environmental monitoring of tritium($^3$H) activity in water sampled liquid scintillation counting( LSC) method is applied to measure low- energy beta activity from tritium in the samples. The $^3$H activity is measured using the BECKMAN 5801 system at the KRISS( Korea Research Institute of Standards and Science) for evaluating the lower limits of detection( LLD) of $^3$H measurement and the measuring capability of low-level $^3$H activity at four nuclear Power Plant sites. The LSC systems used for low-level $^3$H activity measurements at the nuclear Power Plants are confirmed to satisfy throughout an intercomparison study under the experimental arrangements by the KRISS.

  • PDF

회피비용을 고려한 EGEAS 모형 개발과 전원개발계획의 최적화 (A Modified EGEAS Model with Avoided Cost and the Optimization of Generation Expansion Plan)

  • 이재관;홍성의
    • 한국경영과학회지
    • /
    • 제17권1호
    • /
    • pp.117-117
    • /
    • 1992
  • Pubilc utility industries including the electric utility industry are facing a new stream of privatization com-petition with the private sector and deregulation. The necewssity to solve now and in the future power supply and demand problems has been increasing through the sophisticated generation expansion plan(GEP) approach con-sidering not only KEPCo's supply-side resources but also outside resources such as non-utility generation(NUG) demand-side management (DSM). Under the environmental situation in the current electric utility industry a new approach is needed to acquire multiple resources competitively. This study presents the development of a modified electric generation expansion analysis system(EGEAS) model with avoided cost based on the existing EGEAS model which is a dynamic program to develope an optimal generation expansion plan for the electric utility. We are trying to find optimal GEP in Korea's case using our modified model and observe the difference for the level of reliabilities such as the reserve margin(RM) loss of load probability(LOLP) and expected unserved energy percent(EUEP) between the existing EGEAS model and our model. In addition we are trying to calculate avoided cost for NUG resources which is a criterion to evaluate herem and test possibility of connection calculation of avoided cost with GEP implementation using our modified model. The results of our case study are as follows. First we were able to find that the generation expansion plan and reliability measures were largely influenced by capacity size and loading status of NUG resources, Second we were able to find that avoided cost which are criteria to evaluate NUG resources could be calculated by using our modified EGEAS model with avoided cost. We also note that avoided costs were calculated by our model in connection with generation expansion plans.