• 제목/요약/키워드: Electric Energy Management System

검색결과 318건 처리시간 0.03초

도시 및 기후특성이 에너지 회복력에 미치는 영향 - 정전발생시간을 중심으로 - (The Effect of Urban and Climate Characteristics on Energy Resilience - Focusing on Blackout Time -)

  • 이동성;문태훈
    • 국토계획
    • /
    • 제54권4호
    • /
    • pp.122-130
    • /
    • 2019
  • The purpose of this study is to analyze effect of climate and urban factors on energy resilience, and to explore policy alternatives to strengthen resilience of energy system. For this purpose, this study used extensive literature review on resilience studies and multiple regression analysis. In this study, blackout time was set as a dependent variable. And the independent variables were divided into climate and urban (robustness, countermeasure capacity) characteristics. As a result of the analysis, in terms of climate characteristics, maximum wind speed and cooling/heating degree-day have statistically significant impact on blackout time. With regard to urban characteristics, number of consumer, ratio of deteriorated housing and coast dummy variables have statistically significant impact on blackout time. And the ratio of government employees and road ratio were found to be the most influencing factors to shorten time taken to restore original level of electricity supply. Based on the study results, several policy suggestions to improve energy resilience were made such as continuous management of vulnerable areas and strengthening disaster response services. This study only considered engineering dimension of resilience. Further studies need to be approached on ecological & social-ecological dimension.

분산전원이 연계된 배전선로의 운영시스템 설계 (Operation System Design of Distribution Feeder with Distributed Energy Resources)

  • 김성만;장영학;김경훈;김슬기;문채주
    • 한국전자통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1183-1194
    • /
    • 2021
  • 전통적으로 전력시스템은 공급체계의 말단에 있는 소비자의 위치에서 보면 중앙집중화된 구조를 갖고 있다. 그러나 최근 수 십년간 지붕형 태양광, 영농형 태양광, 소형 풍력터빈, 배터리저장장치 및 스마트 가전품과 같은 분산에너지원의 등장을 보아왔다. 분산에너지원의 등장에 따라 배전계통 운전원의 역할도 확장된다. 확장된 분산전원의 진출은 배전망이나 송전망의 전통적인 계획과 운영에 영향을 주는 전력계통의 역조류와 예측성을 어렵게 할 수 있다. 이는 전형적인 계통계획, 정비 및 망관리, 정전할당 등 배전계통 운전원이 갖는 기능이 변경되어야 할 필요성을 증폭시킨다. 이 연구의 목적은 다중 분산전원을 갖는 미래 배전운전시스템을 설계하고 제안된 배전시스템 모델을 HILS로 구현 및 검증하는 것이다. 시험결과를 보면 제안된 배전시스템이 정상 영역에서 운전되고 배전선로 손실이 감소된다는 것을 보여준다.

전력피크부하제어를 위한 CAN 기반 ESS 모니터링 시스템 개발 (Development of Energy Storage System Monitoring for electric peak load control based on CAN protocol)

  • 맹보연;박재신;박종태;이승원
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2014년도 춘계학술발표대회
    • /
    • pp.135-137
    • /
    • 2014
  • 최근 공공건물, 중대형 건물 등에서 전력 피크 시간대에 또는 안정적인 전력공급을 위해 사용할 에너지를 저장하는 방법으로 ESS 를 채택하고 있다. 그러나 대부분의 ESS 의 상태를 모니터링하기 위해서는 별도의 PC 에 소프트웨어를 설치하거나, EMS(Energy Management System)와 같은 별도의 솔루션의 한 기능으로 확인할 수 있다. 이럴 경우, 소프트웨어가 설치되어 있지 않은 현장에서 확인이 어렵고, 자연방전이 일어난 경우 과방전의 가능성도 배제할 수 없다. 따라서 ESS 의 랙 내부에 LCD 화면을 탑재하여 ESS 독립적으로도 상태를 확인할 수 있도록 모니터링 시스템을 개발하였다. 본 연구의 ESS 모니터링 시스템은 ESS 의 안전성올 높이고, 보다 직관적으로 ESS 의 상태를 확인할 수 있도록 구현 하였다.

태양열을 이용한 곡물건조에 관한 연구 (Review on the Use of Solar Energy for Grain Drying)

  • 금동혁;고학균;최재갑
    • Journal of Biosystems Engineering
    • /
    • 제3권1호
    • /
    • pp.64-76
    • /
    • 1978
  • A dimensional supply of petroleum fuels and increased competition for petroleum products has made the conservation of energy in grain drying an important cost and management factor. Research on solar grain drying is directed toward utilization of a renewable energy source as an alternative to petroleum fuels for drying. There are many technical and economic problems in accepting and adopting solor energy as a new energy source for grain drying. The purpose of this study are to assess the state of the art of solar grain drying and to find out the problems by reviewing literatures available. The results obtained may be summarized as follows; 1.It may be considered that the weather conditions in October of Korea was satisfactory for the forced natural air and solar heated air drying. 2. Solar energy is considered more applicable to low-temperature, In-storage drying systems than to high-temperature, high-speed drying systems. In-storage drying systems require low levels of heat input. The costs of collector systems to provide low temperature are considerably cheaper than for high-temperature systems. 3. Tubular type collector made of polyvinyle film seems to be the most practical at this stage of development and black-painted bare-plate collectors mounted on the outside of a typical, round, low-temperature drying bin can supply an appreciable amount of the energy efficiently needed for low-temperature grain drying at a lower cost. 4. All of the grains in solar drying tests was successfully dried up to safe storaged moisture levels without significant spoilage. Drying rates with solar system were faster than natural air drying systems, and usually a little slower than similar low-temperature electric drying systems. 5. Final grain moisture levels were lower in solar tests than in natural air tests, and generally higher than in tests with continuous heated air. 6. Savings of energy by use of solar collectors ranged from 23% to 55%, compared to the natural and electric ileated air drying systems. However, total drying cost effectiteness tvas not significant. Therefore, it is desirable that solar grain dry-ing sIFstems tvhich could be suitable for multiple heating purposes on farms shouldbe developed. 7. Supplemental heat with solar radiation did little to reduce air flow requirementsbut refuced drying time and increased the p\ulcornerobability of successful drying duringdrying poriod.

  • PDF

회피비용을 고려한 EGEAS 모형 개발과 전원개발계획의 최적화 (A Modified EGEAS Model with Avoided Cost and the Optimization of Generation Expansion Plan)

  • 이재관;홍성의
    • 경영과학
    • /
    • 제17권1호
    • /
    • pp.117-134
    • /
    • 2000
  • Pubilc utility industries including the electric utility industry are facing a new stream of privatization com-petition with the private sector and deregulation. The necewssity to solve now and in the future power supply and demand problems has been increasing through the sophisticated generation expansion plan(GEP) approach con-sidering not only KEPCo's supply-side resources but also outside resources such as non-utility generation(NUG) demand-side management (DSM). Under the environmental situation in the current electric utility industry a new approach is needed to acquire multiple resources competitively. This study presents the development of a modified electric generation expansion analysis system(EGEAS) model with avoided cost based on the existing EGEAS model which is a dynamic program to develope an optimal generation expansion plan for the electric utility. We are trying to find optimal GEP in Korea's case using our modified model and observe the difference for the level of reliabilities such as the reserve margin(RM) loss of load probability(LOLP) and expected unserved energy percent(EUEP) between the existing EGEAS model and our model. In addition we are trying to calculate avoided cost for NUG resources which is a criterion to evaluate herem and test possibility of connection calculation of avoided cost with GEP implementation using our modified model. The results of our case study are as follows. First we were able to find that the generation expansion plan and reliability measures were largely influenced by capacity size and loading status of NUG resources, Second we were able to find that avoided cost which are criteria to evaluate NUG resources could be calculated by using our modified EGEAS model with avoided cost. We also note that avoided costs were calculated by our model in connection with generation expansion plans.

  • PDF

신재생에너지 연계형 마이크로그리드의 하이브리드시스템 최적 설계 연구 (A Study on Optimal Design of Hybrid System of New and Renewable Energy-Linked Microgrid)

  • 이재경;한용찬;권성기;박계춘
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.631-638
    • /
    • 2022
  • Microgrid, which enables the production and consumption of electricity to be done independently on a small scale, has been studied on one of the solutions of reinforcement for flexibility of electronic system. This study examined the application effect of new microgrid by applying hybrid battery in electric power storage device. We designed the system to highlight the advantage of each battery and complement the disadvantage by using hybrid system with Lithium-ion battery and interval Redox flow battery. It runs with lithium-ion battery during the initial startup while the Redox flow battery operates for a long time at the end of excessive period, and it enables a discharge of Lithium-ion and Redox flow battery at the same time when the load has a large output. We chose Maldives as a subject of this study for organizing and optimizing independent microgrid. Maldives is the country to accomplish 100% domestic electricity in South Asia, but the whole electric power is supplied through diesel generation imported fossil fuel. We organized and optimized microgrid for energy independence on Malahini island to solve Maldives energy cost problem and global energy environment matters. We analyzed the daily power supply and accumulated the power supply from September 18, 2018~February 11, 2019. The accumulated power supply was about 120.4 MWh and the daily power supply was about 800~1000 kWh. Based on the collected information, we divided the cases into three models which are only diesel generator, solar generator as well as diesel generator, and solar+ESS+diesel generator. We analyzed the amount of oil consumption compared to the cost of construction and power output. The result showed that solar+ESS+diesel generator was most economically feasible. As well, we obtained that our considering hybrid battery system reduced the fuel consumption for diesel power generation about 10~15%.

스마트 FEMS를 위한 VLC기반 인버터 원격제어 연구 (A Study on Remote Control of Inverter Based on VLC for SMART FEMS)

  • 이정훈;이승연;최상열;이종주;김형오
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1382-1387
    • /
    • 2018
  • There is a high demand for energy efficiency improvement of factories that make up a large part of national electric energy. Therefore, research on smart FEMS technology for monitoring, analyzing and controlling energy consumption patterns is under way, but there is still a lack of research on detailed element technology for communication and control inside the factory. In this paper, we proposed OFDM VLC system based on MODBUS protocol for communication between gateways, sensors, and devices to implement smart FEMS in indoor factory environment. Assuming a conveyor belt load control, we validated the proposed system by simulating the inverter motor control and checking the performance.

대학건물의 전력소비패턴 분석을 통한 태양광, ESS 적정용량 산정 및 경제적 효과 분석 (Calculation of Photovoltaic, ESS Optimal Capacity and Its Economic Effect Analysis by Considering University Building Power Consumption)

  • 이혜진;최정원
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.207-217
    • /
    • 2018
  • Recently, the importance of energy demand management, particularly peak load control, has been increasing due to the policy changes of the Second Energy Basic Plan. Even though the installation of distributed generation systems such as Photovoltaic and energy storage systems (ESS) are encouraged, high initial installation costs make it difficult to expand their supply. In this study, the power consumption of a university building was measured in real time and the measured power consumption data was used to calculate the optimal installation capacity of the Photovoltaic and ESS, respectively. In order to calculate the optimal capacity, it is necessary to analyze the operation methods of the Photovoltaic and ESS while considering the KEPCO electricity billing system, power consumption patterns of the building, installation costs of the Photovoltaic and ESS, estimated savings on electric charges, and life time. In this study, the power consumption of the university building with a daily power consumption of approximately 200kWh and a peak power of approximately 20kW was measured per minute. An economic analysis conducted using these measured data showed that the optimal capacity was approximately 30kW for Photovoltaic and approximately 7kWh for ESS.

고효율 회전 집광형 하이브리드 태양광 LED 가로등 모듈 시스템 연구 (A study of high-efficiency rotating condensing hybrid solar LED street light module system)

  • 민경호;전용한
    • Design & Manufacturing
    • /
    • 제15권3호
    • /
    • pp.50-55
    • /
    • 2021
  • Solar power generation, which is one of the methods of using solar energy, has a high possibility of practical implementation compared to other renewable energy power generation, and it has the characteristic that it can generate as much power as needed in necessary places. In addition, maintenance is easy, unmanned operation is possible, and power management can be performed more efficiently if operated in a hybrid method with existing electric energy. Therefore, in this study, numerical analysis using a computer program was performed to analyze the efficient operation and performance improvement of solar energy of the rotating condensing type solar LED street lamp. As a result, the two-axis tracking type could obtain 15.23 % more electricity per year than the fixed type, and additional auxiliary power generation was required for the fixed type by 19 % per year than the tracking type. As a result of computational fluid dynamics(CFD) simulation for PV module surface temperature prediction, the The surface temperature of the Photovoltaics(PV) module incident surface was predicted to be about 10℃ higher than that of the fixed type.

Assessment of Earth Remote Sensing Microsatellite Power Subsystem Capability during Detumbling and Nominal Modes

  • Zahran M.;Okasha M.;Ivanova Galina A.
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.18-28
    • /
    • 2006
  • The Electric Power Subsystem (EPS) is one of the most critical systems on any satellite because nearly every subsystem requires power. This makes the choice of power systems the most important task facing satellite designers. The main purpose of the Satellite EPS is to provide continuous, regulated and conditioned power to all the satellite subsystems. It has to withstand radiation, thermal cycling and vacuums in hostile space environments, as well as subsystem degradation over time. The EPS power characteristics are determined by both the parameters of the system itself and by the satellite orbit. After satellite separation from the launch vehicle (LV) to its orbit, in almost all situations, the satellite subsystems (attitude determination and control, communication and onboard computer and data handling (OBC&DH)), take their needed power from a storage battery (SB) and solar arrays (SA) besides the consumed power in the EPS management device. At this point (separation point, detumbling mode), the satellite's angular motion is high and the orientation of the solar arrays, with respect to the Sun, will change in a non-uniform way, so the amount of power generated by the solar arrays will be affected. The objective of this research is to select satellite EPS component types, to estimate solar array illumination parameters and to determine the efficiency of solar arrays during both detumbling and normal operation modes.